Sun ZFS Storage 7420 PCIe I/O Cards

Sun ZFS Storage 7420 PCIe I/O Options - The Sun ZFS Storage 7420 controller has ten PCIe slots. This table describes base and optional PCIe card slots for standalone and cluster configurations.

Note:

The Sun ZFS Storage 7420 M2 reserves slot 0 for a SAS-2 internal HBA, and slots 1 and 8 for two SAS-2 external HBAs.

Table 11-3 Sun ZFS Storage 7420 Controller PCIe Options

Slot Mfg Part Number Description Max Note

0

7054001

8-port 6Gb/s SAS-2 internal HBA

1

Slot 0 of the 7420 M2 is reserved for the SAS-2 internal HBA

0

371-4325-02

8Gb 2-port FC HBA

6

Optional FC target or initiator (Backup) for the 7420 controller

0

7051223

2-port optical 10GbE NIC

6

Optional recommended front-end for the 7420 controller

0

7054739

4-port copper NIC

6

Optional recommended front-end for the 7420 controller

1

F375-3609-03 (7059331 for EU countries)

2-port SAS external HBA

6

Base configuration (2 minimum)

2

F375-3609-03 (7059331 for EU countries)

2-port SAS external HBA

6

Additional optional back-end

2

7054739

4-port copper NIC

6

Optional recommended front-end

2

371-4325-02

8Gb DP FC HBA

6

Optional FC target or initiator (Backup)

2

375-3606-03

CX1 InfiniBand HCA

4

Optional recommended front-end

2

7051223

2-port optical 10GE NIC

6

Optional recommended front-end

2

375-3696-01

CX2 InfiniBand HCA

4

Optional recommended front-end

3

F375-3609-03 (7059331 for EU countries)

2-port SAS external HBA

6

Additional optional back-end

3

7054739

4-port copper NIC

6

Optional recommended front-end

3

371-4325-02

8Gb 2-port FC HBA

6

Optional FC target or initiator (Backup)

3

375-3606-03

CX1 InfiniBand HCA

4

Optional recommended front-end

3

7051223

2-port optical 10GE NIC

6

Optional recommended front-end

3

375-3696-01

CX2 InfiniBand HCA

4

Optional recommended front-end

4

7054739

4-port copper NIC

6

Optional recommended front-end

4

375-3606-03

CX1 InfiniBand HCA

4

Optional recommended front-end

4

7051223

2-port optical 10GE NIC

6

Optional recommended front-end

4

371-4325-02

8Gb 2-port FC HBA

6

Optional FC target or initiator (Backup)

4

375-3696-01

CX2 InfiniBand HCA

4

Optional recommended front-end

C

7056175

Cluster Controller 200

1

Cluster base configuration

5

7054739

4-port copper NIC

6

Optional recommended front-end

5

375-3606-03

CX1 InfiniBand HCA

4

Optional recommended front-end

5

7051223

2-port optical 10GE NIC

6

Optional recommended front-end

5

371-4325-02

8Gb 2-port FC HBA

6

Optional FC target or initiator (Backup)

5

375-3696-01

CX2 InfiniBand HCA

4

Optional recommended front-end

6

F375-3609-03 (7059331 for EU countries)

2-port SAS external HBA

6

Additional optional back-end

6

7054739

4-port copper NIC

6

Optional recommended front-end

6

371-4325-02

8Gb 2-port FC HBA

6

Optional FC target or initiator (Backup)

6

375-3606-03

CX1 InfiniBand HCA

4

Optional recommended front-end

6

7051223

2-port optical 10GE NIC

6

Optional recommended front-end

6

375-3696-01

CX2 InfiniBand HCA

4

Optional recommended front-end

7

F375-3609-03 (7059331 for EU countries)

DP SAS external HBA

6

Additional optional back-end

7

7054739

4-port copper NIC

6

Optional recommended front-end

7

371-4325-02

8Gb 2-port FC HBA

6

Optional FC target or initiator (Backup)

7

375-3606-03

CX1 InfiniBand HCA

4

Optional recommended front-end

7

7051223

2-port optical 10GE NIC

6

Optional recommended front-end

7

375-3696-01

CX2 InfiniBand HCA

4

Optional recommended front-end

8

F375-3609-03 (7059331 for EU countries)

2-port SAS external HBA

6

Base configuration (2 minimum)

9

371-4325-02

8Gb 2-port FC HBA

6

Optional FC target or initiator (Backup)

9

7051223

2-port optical 10GbE NIC

6

Optional recommended front-end

9

7054739

4-port copper NIC

6

Optional recommended front-end

Sun ZFS Storage 7420 NIC/HBA Options - This table describes NIC/HBA PCIe card options for standalone and cluster Sun ZFS Storage 7420 configurations.

Table 11-4 Sun ZFS Storage 7420 Controller NIC/HBA Options

Mktg Part Number Description Mfg Part Number

SGX-SAS6-INT-Z

8-port 6Gb/s SAS-2 internal HBA

7054001

SG-XPCIE2FC-QF8-Z

2-port 8Gb FC HBA

371-4325-02

SG-XPCIESAS-GEN2-Z

2-port SAS (x4) external HBA

F375-3609-03

7105394

2-port SAS (x4) external HBA for EU countries

7059331

X4446A-Z-N

4-port GigE UTP

7054739

X4242A

2-port CX2 4xQDR, HCA

594-6776-01

X1109A-Z

2-port 10GbE SFP+ NIC

7051223

X2129A

XCVRm 850NM, 1/10GPS, Short Reach, SFP

7015839

X5562A-Z

10GbE/1GbE SFP+ Transceiver, LR

594-6689-01

Sun ZFS Storage 7420 PCIe Slot Order - When installing additional PCIe cards to your base Sun ZFS Storage 7420 configuration, cards must be added in a specific order.

Note:

The Sun ZFS Storage 7420 M2 reserves slot 0 for a SAS-2 internal HBA, and slots 1 and 8 for two SAS-2 external HBAs (see Sun ZFS Storage 7420 PCIe I/O Cards).

Graphic showing the Sun ZFS Storage 7420 controller PCIe cards and slot order

Install optional PCIe cards in the following order:

Table 11-5 Sun ZFS Storage 7420 Controller Optional PCIe Cards and Slot Order

PCIe Card Slot Order

1. SAS-2 external HBA

Slot 2, 7, 3, 6

2. 8Gb FC HBA

Slot 9

Additional FC HBAs are installed last

3. InfiniBand HCAs

Slot 7, 2, 6, 3, 5, 4

4. 10Gb Ethernet

Slot 7, 2, 6, 3, 5, 4, 0 (not available for 7420 M2), 9

5. Quad 1Gb Ethernet

Slot 7, 2, 6, 3, 5, 4, 0 (not available for 7420 M2), 9

6. Remaining 8Gb FC HBAs

Slot 7, 2, 6, 3, 5, 4, 0 (not available for 7420 M2)