Sun ZFS Storage 7420 PCIe I/O Cards
Sun ZFS Storage 7420 PCIe I/O Options - The Sun ZFS Storage 7420 controller has ten PCIe slots. This table describes base and optional PCIe card slots for standalone and cluster configurations.
Note:
The Sun ZFS Storage 7420 M2 reserves slot 0 for a SAS-2 internal HBA, and slots 1 and 8 for two SAS-2 external HBAs.Table 11-3 Sun ZFS Storage 7420 Controller PCIe Options
Slot | Mfg Part Number | Description | Max | Note |
---|---|---|---|---|
0 |
7054001 |
8-port 6Gb/s SAS-2 internal HBA |
1 |
Slot 0 of the 7420 M2 is reserved for the SAS-2 internal HBA |
0 |
371-4325-02 |
8Gb 2-port FC HBA |
6 |
Optional FC target or initiator (Backup) for the 7420 controller |
0 |
7051223 |
2-port optical 10GbE NIC |
6 |
Optional recommended front-end for the 7420 controller |
0 |
7054739 |
4-port copper NIC |
6 |
Optional recommended front-end for the 7420 controller |
1 |
F375-3609-03 (7059331 for EU countries) |
2-port SAS external HBA |
6 |
Base configuration (2 minimum) |
2 |
F375-3609-03 (7059331 for EU countries) |
2-port SAS external HBA |
6 |
Additional optional back-end |
2 |
7054739 |
4-port copper NIC |
6 |
Optional recommended front-end |
2 |
371-4325-02 |
8Gb DP FC HBA |
6 |
Optional FC target or initiator (Backup) |
2 |
375-3606-03 |
CX1 InfiniBand HCA |
4 |
Optional recommended front-end |
2 |
7051223 |
2-port optical 10GE NIC |
6 |
Optional recommended front-end |
2 |
375-3696-01 |
CX2 InfiniBand HCA |
4 |
Optional recommended front-end |
3 |
F375-3609-03 (7059331 for EU countries) |
2-port SAS external HBA |
6 |
Additional optional back-end |
3 |
7054739 |
4-port copper NIC |
6 |
Optional recommended front-end |
3 |
371-4325-02 |
8Gb 2-port FC HBA |
6 |
Optional FC target or initiator (Backup) |
3 |
375-3606-03 |
CX1 InfiniBand HCA |
4 |
Optional recommended front-end |
3 |
7051223 |
2-port optical 10GE NIC |
6 |
Optional recommended front-end |
3 |
375-3696-01 |
CX2 InfiniBand HCA |
4 |
Optional recommended front-end |
4 |
7054739 |
4-port copper NIC |
6 |
Optional recommended front-end |
4 |
375-3606-03 |
CX1 InfiniBand HCA |
4 |
Optional recommended front-end |
4 |
7051223 |
2-port optical 10GE NIC |
6 |
Optional recommended front-end |
4 |
371-4325-02 |
8Gb 2-port FC HBA |
6 |
Optional FC target or initiator (Backup) |
4 |
375-3696-01 |
CX2 InfiniBand HCA |
4 |
Optional recommended front-end |
C |
7056175 |
Cluster Controller 200 |
1 |
Cluster base configuration |
5 |
7054739 |
4-port copper NIC |
6 |
Optional recommended front-end |
5 |
375-3606-03 |
CX1 InfiniBand HCA |
4 |
Optional recommended front-end |
5 |
7051223 |
2-port optical 10GE NIC |
6 |
Optional recommended front-end |
5 |
371-4325-02 |
8Gb 2-port FC HBA |
6 |
Optional FC target or initiator (Backup) |
5 |
375-3696-01 |
CX2 InfiniBand HCA |
4 |
Optional recommended front-end |
6 |
F375-3609-03 (7059331 for EU countries) |
2-port SAS external HBA |
6 |
Additional optional back-end |
6 |
7054739 |
4-port copper NIC |
6 |
Optional recommended front-end |
6 |
371-4325-02 |
8Gb 2-port FC HBA |
6 |
Optional FC target or initiator (Backup) |
6 |
375-3606-03 |
CX1 InfiniBand HCA |
4 |
Optional recommended front-end |
6 |
7051223 |
2-port optical 10GE NIC |
6 |
Optional recommended front-end |
6 |
375-3696-01 |
CX2 InfiniBand HCA |
4 |
Optional recommended front-end |
7 |
F375-3609-03 (7059331 for EU countries) |
DP SAS external HBA |
6 |
Additional optional back-end |
7 |
7054739 |
4-port copper NIC |
6 |
Optional recommended front-end |
7 |
371-4325-02 |
8Gb 2-port FC HBA |
6 |
Optional FC target or initiator (Backup) |
7 |
375-3606-03 |
CX1 InfiniBand HCA |
4 |
Optional recommended front-end |
7 |
7051223 |
2-port optical 10GE NIC |
6 |
Optional recommended front-end |
7 |
375-3696-01 |
CX2 InfiniBand HCA |
4 |
Optional recommended front-end |
8 |
F375-3609-03 (7059331 for EU countries) |
2-port SAS external HBA |
6 |
Base configuration (2 minimum) |
9 |
371-4325-02 |
8Gb 2-port FC HBA |
6 |
Optional FC target or initiator (Backup) |
9 |
7051223 |
2-port optical 10GbE NIC |
6 |
Optional recommended front-end |
9 |
7054739 |
4-port copper NIC |
6 |
Optional recommended front-end |
Sun ZFS Storage 7420 NIC/HBA Options - This table describes NIC/HBA PCIe card options for standalone and cluster Sun ZFS Storage 7420 configurations.
Table 11-4 Sun ZFS Storage 7420 Controller NIC/HBA Options
Mktg Part Number | Description | Mfg Part Number |
---|---|---|
SGX-SAS6-INT-Z |
8-port 6Gb/s SAS-2 internal HBA |
7054001 |
SG-XPCIE2FC-QF8-Z |
2-port 8Gb FC HBA |
371-4325-02 |
SG-XPCIESAS-GEN2-Z |
2-port SAS (x4) external HBA |
F375-3609-03 |
7105394 |
2-port SAS (x4) external HBA for EU countries |
7059331 |
X4446A-Z-N |
4-port GigE UTP |
7054739 |
X4242A |
2-port CX2 4xQDR, HCA |
594-6776-01 |
X1109A-Z |
2-port 10GbE SFP+ NIC |
7051223 |
X2129A |
XCVRm 850NM, 1/10GPS, Short Reach, SFP |
7015839 |
X5562A-Z |
10GbE/1GbE SFP+ Transceiver, LR |
594-6689-01 |
Sun ZFS Storage 7420 PCIe Slot Order - When installing additional PCIe cards to your base Sun ZFS Storage 7420 configuration, cards must be added in a specific order.
Note:
The Sun ZFS Storage 7420 M2 reserves slot 0 for a SAS-2 internal HBA, and slots 1 and 8 for two SAS-2 external HBAs (see Sun ZFS Storage 7420 PCIe I/O Cards).![Graphic showing the Sun ZFS Storage 7420 controller PCIe cards and slot order Graphic showing the Sun ZFS Storage 7420 controller PCIe cards and slot order](img/a3226-pcie-locator.jpg)
Install optional PCIe cards in the following order:
Table 11-5 Sun ZFS Storage 7420 Controller Optional PCIe Cards and Slot Order
PCIe Card | Slot Order |
---|---|
1. SAS-2 external HBA |
Slot 2, 7, 3, 6 |
2. 8Gb FC HBA |
Slot 9 Additional FC HBAs are installed last |
3. InfiniBand HCAs |
Slot 7, 2, 6, 3, 5, 4 |
4. 10Gb Ethernet |
Slot 7, 2, 6, 3, 5, 4, 0 (not available for 7420 M2), 9 |
5. Quad 1Gb Ethernet |
Slot 7, 2, 6, 3, 5, 4, 0 (not available for 7420 M2), 9 |
6. Remaining 8Gb FC HBAs |
Slot 7, 2, 6, 3, 5, 4, 0 (not available for 7420 M2) |