Oracle GoldenGate Classic Architecture uses the data pump Extract in GGSCI to connect to Microservices Architecture.
Follow these steps for establishing a connection betweenOracle GoldenGate Microservices Architecture and Classic Architecture:
Note:
To perform this task, an existing data pump Extract must be running in Classic Architecture.Log in to GGSCI.
Add a data pump Extract using the command:
ADD EXTRACT dp_name, EXTTRAILSOURCE ./dirdat/aa
This example uses, dp_name
as the name of the data pump Extract.
Add the remote trail to the data pump Extract using the command:
ADD RMTTRAIL ab, EXTRACT dp_name, MEGABYTES 500
Edit the parameter file for the data pump Extract using the command:
EDIT PARAMS dp_name
Here’s an example of the data pump Extract parameter file:
EXTRACT dp_name RMTHOST hostname/IP address, PORT receiver service port RMTTRAIL ab PASSTHRU TABLE pdb.schema.table;
Use the following command to start the data pump Extract dp_name
:
START EXTRACT dp_name
Once the data pump Extract has started, the Receiver Server establishes a path and begins reading the remote trail file. The remote trail file appears in the $OGG_VAR_HOME/lib/data
of the associated deployment running the Receiver Server.