C Connecting Oracle GoldenGate Classic Architecture to Microservices Architecture

Oracle GoldenGate Classic Architecture uses the data pump Extract in GGSCI to connect to Microservices Architecture.

Follow these steps for establishing a connection betweenOracle GoldenGate Microservices Architecture and Classic Architecture:

Create a data pump Extract

Note:

To perform this task, an existing data pump Extract must be running in Classic Architecture.
  1. Log in to GGSCI.

  2. Add a data pump Extract using the command:

    ADD EXTRACT dp_name, EXTTRAILSOURCE ./dirdat/aa

    This example uses, dp_name as the name of the data pump Extract.

  3. Add the remote trail to the data pump Extract using the command:

    ADD RMTTRAIL ab, EXTRACT dp_name, MEGABYTES 500
    
  4. Edit the parameter file for the data pump Extract using the command:

    EDIT PARAMS dp_name
    

    Here’s an example of the data pump Extract parameter file:

    EXTRACT dp_name
    RMTHOST hostname/IP address, PORT receiver service port
    RMTTRAIL ab
    PASSTHRU
    TABLE pdb.schema.table;
    
    
Start the data pump Extract

Use the following command to start the data pump Extract dp_name:

START EXTRACT dp_name