Create a JMX notification action

Before you begin

Create diagnostic system modules


For each defined JMX notification action, WLDF issues JMX events (notifications) whenever an associated policy is triggered.

To create a new JMX notification action:

  1. If you have not already done so, in the Change Center of the Administration Console, click Lock & Edit (see Use the Change Center).
  2. In the left pane of the Console, select Diagnostics > Diagnostic Modules.
  3. In the Diagnostic System Modules table, select the name of the diagnostic system module you want to assign the action to.
  4. Select Configuration > Policies and Actions > Actions.
  5. Click New.
  6. Select JMX Notification from the Type list and click Next.
  7. Enter a name for the action in the Action Name field.
  8. Enter the timeout period in the Timeout (in seconds) field. The timeout period is the length of time, in seconds, that an action has to complete execution. By default, the timeout period is 0, which disables the action timeout.
  9. In Notification Type, enter the type of notification that should be assigned to this JMX notification action.
  10. To enable or disable this action, select or deselect the Enable Action box.
  11. Click OK.
  12. In the Change Center, click Activate Changes.