Note:
All information about deprecated and removed functionality in WebLogic Server is documented in What's New in Oracle WebLogic Server 12.2.1.2.0, in the following sections:
This chapter includes the following sections:
This section describes the following issues and workarounds:
Multi-Byte Characters Display Incorrectly in Filenames When Using Safari
Strong Password Enforcement May Cause Issues With WLST Offline Scripts
Administration Server Reports a 'Too Many Open Files' Message on the EM Console
Partition with Japanese name cannot be created from Fusion Middleware Control
Platform: All
When using the Safari browser to download content, if a filename contains multi-byte characters, the characters are displayed as '------' in the filename.
Workaround
Set UseHeaderEncoding
to true
on the Managed Server. Use the following WLST commands to do so:
connect("admin_name", "admin_password", "t3://localhost:port") edit() startEdit() cd("Servers/server_name/WebServer/server_name") set("UseHeaderEncoding", "true") save() activate() exit()
Platform: All
With the implementation of strong password enforcement (8 character minimum with one numeric or special character) in this release of WebLogic Server, existing scripts could potentially encounter issues.
Workaround
Use either of the following workarounds to bypass the new password restrictions.
Set the BACKWARD_COMPAT_PW_CHECK
environment variable to true
.
Include the -Dbackward.compat.pw.check=true
option when invoking WLST.
Oracle recommends that you change passwords to comply with the new password requirements, as this variable and option will be removed in a future release of WebLogic Server.
Platform: All
Any applications that use an MDS repository cannot be deployed or run with the JAXB version bundled with WebLogic Server as null values are returned for attributes named id
.
Workaround
Start the server in English locale.
Platform: Linux
The WebLogic Server Administration Server reports a Too Many Open Files
message on the Enterprise Manager (EM) console when the maximum number of file descriptors configured for the Administration Server is less than 65535.
Workaround
Execute the following command to determine the maximum number of file descriptors currently configured:
cat /proc/sys/fs/file-max
If the value is less than 65535, perform the following steps:
Coherence users who do not have a dependency on WebLogic Server, and who want to use Maven, should use the standalone Coherence installer.
Coherence users who do have a dependency on WebLogic Server who want to use Maven must choose the "WebLogic Server" or "Complete with Examples" installation options. Do not choose the "Coherence Installation" option.
Platform: All
The default WebLogic Server message prefix will change from BEA to WL in a future release of WebLogic Server.
The utility Apache packages, com.bea.util.jam
and com.bea.util.jam.visitor
are incorrectly published in the Java API Reference document as being open-source.
These packages are not intended for public consumption.
Platform: All
Partition with Japanese name cannot be created due to Life cycle Exception
on Fusion Middleware Control.
Workaround
Create a partition which uses an English name or create a Japanese name partition from WebLogic Server Administration Console.
This section describes the following issues and workarounds:
Administration Console Does Not Always Reflect External Changes Made in a Deployment Plan
Application Testing Links Fail to Resolve in Administration Console
Error When Configuring Security Role For Newly Created Coherence Cluster Service or Cache
Inconsistent Behavior Between Consoles When Creating a Partition
Platform: All
After a page flow completes in the WebLogic Server Administration Console, it forwards to a different page, typically a table.
Pressing the browser Back button at this point results in an attempt to load the last JSP file in the completed assistant. At this point, all of the context for this assistant is discarded.
Workaround
Oracle recommends that you do not use the browser Back button to step back into an assistant once changes are cancelled or finished, and that you do not go back to a previous step in an assistant. Instead, use the navigation links and buttons in the WebLogic Server Administration Console.
Platform: All
The WebLogic Server Administration Console permits the creation of Work Manager configurations that are not supported and do not function as intended. Incorrect Work Manager configurations may result in a number of exceptions being recorded in the server logs, most commonly 'Validation problems were found'
exceptions while parsing deployment descriptors.
Workaround
Follow the guidelines described in the online help for Work Manager configurations. Specifically, you can only assign one request class to any given Work Manager, and that request class must be of the same or a broader scope than the Work Manager. You should not assign an application-scoped request class to a global Work Manager, and you should not create more than one application-scoped request class for an application-scoped Work Manager.
Correcting the Work Manager configurations to match the documented constraints resolves these issues.
Platform: All
The Server Status table on the Cluster: Monitoring: Summary page includes two default columns: Primary and Secondary Distribution Names. These fields do not always reflect all of the replication statistics that are collected and displayed on the Cluster: Monitoring: Failover page, depending on the replication scenario.
Please refer to the Cluster: Monitoring: Failover page for definitive information.
Platform: All
When defining security policies in the WebLogic Server Administration Console for an EJB deployment that references types defined in a separate library deployment, exceptions can be observed if that library deployment is not available to the Console.
Workaround
All library deployments should be targeted at the WebLogic Server Administration Server as well as any Managed Servers needed to support referencing applications. This will ensure that when defining policies, the Console will have access to those library deployments so that referenced types can be class-loaded as needed.
Platform: All
The WebLogic Server Administration Console does not always reflect external changes made in a deployment plan. If a change is made in a deployment plan outside of the Console (for example, using Workshop, editing the plan text files directly, or updating a deployment with a new plan using WLST or webLogic.Deployer) while a Console user is also viewing that deployment plan, the Console user will not see those changes.
Workaround
Navigate to a configuration page for a different deployment, then navigate back to the original deployment again.
Platform: All
In some configurations, the Application Testing pages included in the WebLogic Server Administration Console use IPv6 addresses in the testing links. These addresses are valid for WebLogic server instances, but in some mixed IPv4 and IPv6 environments, these addresses cannot be used from the browser to interact with applications and the testing links cannot be resolved.
Workaround
This scenario typically happens when an administrator does not specify the listen address for a server in the configuration and the server is running on a dual stack (IPv6/IPv4) machine where Java and the operating system are configured to use IPv6 in preference to IPv4. In these mixed environments where the IPv4 stack cannot communicate with IPv6, Oracle recommends starting all server instances with the following command so that all servers are downgraded to use IPv4 only:
-Djava.net.preferIPv4Stack=true
Platform: All
While using the WebLogic Server Administration Console with applications or EJBs deployed on a Managed Server that depend on a deployed library, you may encounter a java.lang.NoClassDefFoundError
.
Workaround
The WebLogic Server Administration Console needs access to any shared library deployments so that Java data types and annotations can be processed. Therefore, all shared library deployments should always be targeted to the WebLogic Server Administration Server in addition to any Managed Servers or clusters.
Platform: All
An unexpected error condition is noted in the WebLogic Server Administration Console when configuring a security role for a newly created Coherence cluster service or cache. It is a common pattern in the WebLogic Server Administration Console that newly created artifacts must be saved and activated before it is possible to access them to configure security roles and policies on those artifacts. Many console pages check this and display a message indicating that "This page is not available because the necessary security providers have not been configured, or those configuration changes are pending and not yet activated. Please activate the changes and (if necessary) restart the Administration Server to make this page available." This check is not present in the Coherence security pages.
Workaround
After creating a new Coherence cluster, activate the configuration changes and restart any servers as indicated in the restarts changelist. This ensures that the Coherence cluster resources are available for role and policy configuration.
Platform: MS Windows
The option to start Node Manager on Windows machines using a shortcut on the Start menu has been removed in WebLogic Server 12.1.2.
Workaround
Ignore this text: "On Windows, you can start Node Manager using a shortcut on the Start menu."
Use other methods to start Node Manager. See Starting and Stopping Node Managerin Administering Node Manager for Oracle WebLogic Server.
Platform: All
Console extensibility is deprecated as of WebLogic Server 12.1.3. The related documentation, Extending the Administration Console for Oracle WebLogic Server and the Java API Reference for the Oracle WebLogic Server Administration Console, have been removed from the documentation set.
Platform: All
Partitions created in the WebLogic Server Administration Console that do not contain a virtual target and resource group are not displayed on the Partition Monitoring page in Fusion Middleware Control (FMWC). These partitions are displayed in the FMWC partitions table with an unknown status.
Workaround
As a workaround, select the partitions in the FMWC partitions table and add a virtual target and a resource group.
There are no known Apache Beehive Support issues in this release of WebLogic Server.
This section describes the following issues and workarounds:
Platform: Linux
When using Unicast mode for cluster communication, many threads are blocked on cluster messaging, which may result in cluster members having difficulty sending heartbeat messages. In this situation, some cluster members drop out from the cluster and may take some time to rejoin the cluster.
Platform: All
To support elasticity, WebLogic Server 12.2.1 introduced the following configurable constraints on the minimum and maximum size of a dynamic cluster:
MinDynamicClusterSize (default=1)
MaxDynamicClusterSize (default=8)
Additionally, the MaximumDynamicServerCount attribute is deprecated and replaced with the DynamicClusterSize attribute. The value of this attribute is validated against the previously mentioned minimum and maximum constraints. As a result, some existing user configurations and/or scripts may fail. If this occurs, you need to update the MaxDynamicClusterSize setting appropriately so that the DynamicClusterSize value is within the limits.
Platform : All
When HTTP POST
requests are serviced by clustered WebLogic Server applications, which are configured with a load balancer such as Oracle HTTP Server, a web server using a WebLogic Server proxy plug-in, or Oracle Traffic Director, an HTTP 503 error can occur. If a POST request has been sent to a WebLogic Server clustered Managed server that is shutting down, and if the server is unable to complete the request, or if the result of the request is unknown, then the load balancer is required to return an HTTP 503 error. When Oracle Traffic Director is used with dynamic clusters, and the cluster is being scaled down, WebLogic Server notifies Oracle Traffic Director of the impending graceful shutdown of the servers and attempts to route requests to the remaining servers in the cluster. However, there may be a brief downtime in between the graceful shutdown operation and before Oracle Traffic Director redirects the HTTP traffic, when some HTTP requests may receive the 503 error.
This section describes the following issues and workarounds:
ASProvWorkflowException Occurs When Creating a WebLogic Domain
Use the -Dfile.encoding Property When Running WLST in a Non-English Locale
Configuration Tools Can Fail If WebLogic Installation Path Contains Spaces
Abnormal Behavior in Terminal Window After Entering WebLogic Password
Password Field Is Not Editable When Configuring a New Domain
Administration Server Memory Consumption and JMX Notifications
Changing Domain From Development To Production Mode Does Not Change Start Scripts
Partition Listener May Not Receive MBean Unregistration Notification
No Support for Explicit Port and Port Offset for Global Virtual Targets
Bi Cluster1 is Down on Pure IPv6 Deployment after Configuration
Platform: All
In rare cases, if your installation environment contains existing JAVA_OPTIONS prior to starting a Fusion Middleware product installation, these may cause an ASProvWorkflowException
, preventing the domain from being created.
Workaround
Prior to starting the Fusion Middleware product installation, clear the existing JAVA_OPTIONS. If you have an application in the environment that use these JAVA_OPTIONS, the applications may not work after clearing the options. In this case, save the existing JAVA_OPTIONS to a text file and investigate alternatives for running your other application.
Platform: MS Windows
WLST can be run with localized messages by setting the desired locale. You should be aware of the following issue when running WLST in a non-English locale.
On Windows operating systems, if a DOS command window's active code page is different from the system's local (ANSI) code page, you must add the -Dfile.encoding=<
DOS window's active code page
>
property to the WLST process when starting WLST via a DOS command window. This changes the default character set for the Java process. For example:
The active code page for a DOS window is 850. This can be achieved by issuing the chcp
command in the WLST command window.
The system's local (ANSI) code page is 1250. You can determine the system's local code page by viewing the value of the HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\NLS\CodePage\ACP key in the Windows registry. Files that are created by standard Windows editing tools (such as Notepad or Wordpad) are encoded in this way.
In this situation, you can start WLST as follows:
set WLST_PROPERTIES="-Dfile.encoding=cp850"
$WL_HOME%\common\bin\wlst.cmd
Platform: MS Windows
On some Microsoft Windows platforms, the WebLogic configuration tool commands (including wlst
, config
, pack
, and unpack
) can fail if the WebLogic installation path contains a space. In this case, the command may fail with a java.lang.ClassNotFoundException
, where the class is derived from the portion of the installation path after the space. The commands fail when short file name generation has been disabled in the Windows registry.
Workaround
You must enable short name generation in the Windows registry in order for spaces to be properly handled by the configuration tools. To enable short name generation:
regedit
.NtfsDisable8dot3NameCreation
and set its value to 0
.Platform: All
If you attempt to connect to the WebLogic Server Administration Server with a non-existent server name, a directory for the non-existent server name is created under the domain_name
/servers
directory.
Workaround
Specify a valid server name when starting the Managed Server.
Platform: Linux
After pressing Ctrl-C to terminate the startManagedWebLogic.sh
process immediately after entering the WebLogic password, abnormal behavior may be experienced in the terminal window. For example, when pressing Return, the prompt is tabbed instead of going to the next line, and any characters that are entered at the prompt are not displayed in the terminal.
Workaround
Either close the current xterm and start a new one, or enter stty echo
into the xterm.
Platform: Linux
It can take a long time to create or update WebLogic Server domains when:
Installing WebLogic Server on UNIX or Linux operating systems if the Server Examples are included in the installation.
Using the WebLogic Server Configuration Wizard to create or update a domain.
Using WLST to create or update a domain.
Workaround
Set the CONFIG_JVM_ARGS environment variable to the following value:
-Djava.security.egd=file:/dev/./urandom
Platform: Linux
On Linux systems, when creating a new domain in the Oracle Fusion Middleware Configuration Wizard, the Password and Confirm Password fields are sometimes not editable, and you cannot enter a password to create a domain.
Workaround
There are two ways to work around this issue:
To work around the issue each time it happens, click the Close Window X button in the upper right corner of the Configuration Wizard. In the confirmation dialog that appears, click No to return to the Configuration Wizard. You can then enter and confirm the password for the domain.
To fix this issue permanently:
Kill all scim processes. For example:
kill `pgrep scim`
Modify (or create) the file ~/.scim/config
to include the following line (case-sensitive):
/FrontEnd/X11/Dynamic = true
If you are running VNC, restart the VNC server.
Run the Configuration Wizard again.
Platform: All
The Domain Runtime MBean Server is a federated MBean server with connections to all Managed Server Runtime MBean Servers in the domain. The federation architecture performs well with queries. However, when JMX notifications are added to MBeans, the Domain Runtime MBean Server can consume large amounts of memory.
When JMX notifications are used, two cases exist that cause the Administration Server to keep copies of all JMX object names registered in all Runtime MBean Servers running in all Managed Servers in the domain:
At the WebLogic Server level, to simulate the unregister MBean notifications when a Managed Server shuts down.
At the JDK JMX client notification layer.
The likelihood of encountering this issue increases when both of the following conditions exist:
EM Fusion Middleware Control is being used to manage large domains, as it adds notification listeners to the Domain Runtime MBean Server.
Fusion Middleware products that significantly increase the number of JMX runtime MBeans are included in the domain. This would include any product with MBeans that are registered in WebLogic Server Runtime MBean Server instances running in the domain; that is, in the Administration Server as well as all Managed Servers. (These products include Coherence, SOA Suite, OSB, and so on.)
Workaround
Disable the managed-server-notifications-enabled
attribute. This configuration attribute disables the ability to define notifications on MBeans that are contained in the Managed Servers Runtime MBean Servers (these MBeans contain a Location=key
in the ObjectName).
If Managed Server notifications are disabled, then the two sets of ObjectNames for MBeans contained in the WebLogic Server and JDK components will not be kept. Notifications listeners can still be defined on the MBeanServerDelegate and on MBeans contained in the local Domain Runtime MBean Server. However, notifications listeners cannot be added to the non-local MBeans.
The managed-server-notifications-enabled
attribute can be set using WLST as follows:
edit() startEdit() cd("JMX/domain-name") cmo.setManagedServerNotificationsEnabled(false) activate()
editCustom()
MBeansPlatform: All
The editCustom()
tree contains MBeans for upper stack and system component products. If you make changes to these MBeans, the changes are persisted immediately to the pending directory. This is different from the WebLogic Server MBeans in the edit()
tree, which require an explicit save.
If you use stopEdit()
, cancelEdit()
or exit WLST with an open edit session, then the unsaved changes to the WebLogic Server MBeans will be rolled back. However, the changes to the editCustom()
tree will not be rolled back since they have been persisted.
Workaround
Use the undo('y')
command to rollback the unactivated changes to the editCustom()
MBeans.
Platform: All
Two development servers cannot be started on the same host if they are sharing a single Derby instance.
Workaround
Configure each development server to use its own unique instance of Derby instead of sharing a single Derby instance. For more information see Running Each Domain with a Unique Derby Instance in Developer's Guide for Oracle Service Bus.
Platform: All
If the WebLogic Server Configuration Wizard (config.sh
) is used to create a domain and the WebLogic Coherence Cluster Extension template is specified, then a Coherence cluster will be defined. The Coherence cluster will be associated with any Managed Server or WebLogic Server cluster that is also created by the Configuration Wizard. If no Managed Server or WebLogic Server cluster is created, then the Coherence cluster will be associated with the Administration Server. This association between the Coherence cluster and the servers is not completely defined using the WebLogic Server configuration tool, which results in the Coherence cache configuration override file not being detected by the Coherence cluster. Please note that this issue only occurs if you are using the cache override feature.
Workaround
Use the following workaround:
This will perform a complete association between the Coherence cluster and the targeted servers, which is required to detect and utilize the specified Coherence cluster cache configuration override file.
Platform: All
Specify -managed=true
when creating a Managed Server domain directory from a template. If you do not specify -managed=true
, the Managed Server will fail to boot because it does not have the correct set of files in the security directory.
Platform: All
When you change a domain from development mode to production mode:
The domain start scripts (and the value of the -Xverify
flag) do not change.
The boot.properties
file continues to be in use.
Workaround
In production mode domains:
The value of the -Xverify
flag in the start scripts needs to be changed from none
to all
.
The boot.propeties
file needs to be removed. See Development and Production Mode in Understanding Domain Configuration for Oracle WebLogic Server.
Platform: All
When executing a WLST script or WLST command, a TypeError: state(): 1st arg can't be coerced to String error occurs
. This error occurs because a WLST class name server
was used as a variable name in a WLST command. For example, in the following command, the value for the variable server
will be replaced with its class name during classloading and will therefore cause this error:
state(server,'Server')
Workaround
Use one of the following workarounds:
Include the -Dpython.cachedir.skip=true
parameter when starting WLST.
Change the reserved string name to another string. For example, you can change the string name server
to srvr
to resolve the issue.
In some cases, a partition listener may not receive notifications when an MBean is unregistered from an MBean server, even though the partition is enabled to receive notifications. This is due to some limitation in the current implementation of WebLogic Server 12.2.1.
Workaround
Currently there is no known workaround for this issue.
Changes to an existing RG and RGT scoped non-module configurations may be ignored even after a partition restart. Changes to resource group overrides may also be ignored. However, changes to module-scoped configurations such as data source tuning, JMS destinations, and connection factories are unaffected by this issue.
The changes appear to be correct if queried via WLST but old values continue to be consumed within the server instance.
Workaround
Restart the server for the new values to take effect.
This issue occurs when there are two resource group templates containing resources of the same type and sharing the same name.
When a resource group is initially targeted to one resource group template, and is then targeted to the second resource group template, and changes are then made to the resource with the shared name in the second resource group template, those changes may not be reflected. The resource group might continue to use the value from the resource in the first resource group template.
Workaround
To bypass this issue, use either of the following workarounds:
Avoid using resources with the same name across multiple resource group templates.
After making changes to the resource in the second resource group template, restart the server for the new changes to take effect.
WebLogic Server provides support for setting the Explicit port and port offset for virtual targets. However, currently the setting for Explicit port and port offset can take effect only for virtual targets that are assigned to a partition. For Global Virtual Targets (the virtual targets that are not assigned to any partition), the settings for Explicit port and port offset do not take effect.
Due to recent changes in JDK, WebLogic Server no longer supports JMX with just the wlclient.jar
file. To use JMX, you must use either the WebLogic full client, (weblogic.jar)
, or the wljmxclient.jar
file.
This is on a pure IPv6 environment. After installing WLS and configuring BI, the bi_cluster is down. This was not reported by the configuration wizard.
Workaround
Login to WLS console, stop bi_server1 and then start bi_cluster1. After this step, start bi_server1 to resolve the issue.
This section describes the following issues and workarounds:
There are no known Extensions issues in this release of WebLogic Server.
This section describes the following issues and workarounds:
Servers Configured to Listen on a Host Name Are Listening on a Different Host Name After Startup
Administration Server or Node Manager Cannot Track the Status of a Managed Server
Multicast Traffic Observed to be Unreliable During or After a Network Partition
Initial Connection May Remain Open When Using t3 Protocol with External Load Balancers
Managed Server Fails to Start When Added to Multicast Cluster
High Number of Application Threads May Cause a Server to Stall
Enterprise Beans Can be Accessed by Remote Clients When Annotated with @Local
Platform: All
When a machine that is hosting one of the Managed Servers is abruptly shut down, a network cable is pulled, or its network interface card has issues, and any server attempts communication with that managed server, threads become stuck waiting to get a connection.
Workaround
This can currently be resolved by using a private flag:
-Dweblogic.client.SocketConnectTimeoutInSecs
and setting an appropriate timeout value that will release the thread attempting to make the connection and allow the request to fail quickly.
For more information about timeout properties, see Setting Client Timeouts in Developing RMI Applications for Oracle WebLogic Server.
Platform: All
When using an IPv6-formatted address for WebLogic Server, the URL should include square brackets ('[' and ']') for the host address. Otherwise, WLST may fail to connect to the running server.
Workaround
Add square brackets to the host address. For example:
t3://[fe80:0:0:0:203:baff:fe2f:59e5]:9991
Platform: All
If the WebLogic Server Administration Server is down when a Whole Server Migration occurs for a clustered server, and the server migrates to a machine on which it was never run before, the server cannot be started on the new machine.
Workaround
Use one of the following workarounds for this issue:
Ensure that the Administration Server is up when the server migration is being performed.
Use a shared disk/NFS for all the migratable servers in the cluster.
Platform: All
When FastSwap is enabled in a J2EE application, you can make certain types of changes to Java classes during development and expect to see the change without re-deploying, with all instance states of the Java object being retained.
One type of change that does NOT retain the object state is that when a field name is changed, it is treated as follows:
the field with old name is deleted
the field with new name is added
Thus, in this case, any state in the old field is not carried over to the renamed field.
Using the Workshop or FastSwap ant task, you may see a FastSwap operation completed successfully
message, even when an instance field name change causes a value reset.
Workaround
You should expect an instance value to be reset when you change a field name.
Platform: All
When using a host name to specify configuring the listen address on the WebLogic Server Administration Server or a Managed Server, machines that are configured with multiple Ethernet cards may listen on a different host name after startup. For example:
The machine has 3 Ethernet cards
Card 1 is mapped to hostname1-s
(DNS registered host name)
Card 2 is mapped to hostname1-i
(DNS registered host name)
Card 3 is mapped to hostname1
(actual node's host name)
You configure the server to listen on hostname1
After starting the server, it is listening on hostname1-s
because Windows resolves the actual node's host name to the first enabled Ethernet card address
Workaround
Use one of the following three workarounds for this issue:
Platform: Linux
If you start a managed server by providing an incorrect WebLogic Server Administration Server URL from the command line (that is, the Administration Server cannot be reachable at the provided URL), the managed server will start in Managed Server Independence (MSI) mode.
In this case, neither the Administration Server nor Node Manager can track the status of the managed server. The WebLogic Server Administration Console will show the status of the managed server as UNKNOWN, but the server will actually be RUNNING in MSI mode.
Platform: Linux
During or after a network partition that causes a server migration to take place, multicast traffic has been observed to be unreliable. For example, one node may be receiving multicast traffic, but traffic originating from this node is not received on other nodes in the network. As a result, the migrated servers are not added to the cluster because their heartbeats were not received.
Workaround
Currently, the only known workaround is to use unicast cluster messaging.
Platform: All
WebLogic Server does not support Java DB for migration. There is no leasing script available in the WL_HOME
/server/db
directory for Java DB.
There is no workaround for this issue.
Platform: All
When using the t3
protocol with external load balancers, the initial connection may remain associated with the IP address of the load balancer used to do the bootstrap into the cluster. Therefore, a small percentage of requests may pass through the load balancer after the initial connection. This behavior, if present, is a side-effect of the implementation that should not be relied upon since Oracle reserves the right to change this behavior at any point in time.
Platform: All
If you have a cluster containing at least two Managed Servers, and the messaging mode of the cluster is set to multicast, then the Managed Servers in the cluster will fail to start.
Workaround
To workaround this issue, add the following property to JAVA_OPTIONS
in the startup script startWebLogic.sh
. For example:
export JAVA_OPTIONS="${JAVA_OPTIONS} –Djava.net.preferIPv4Stack=true"
In some cases, a server JVM may stall and a thread dump of the stalled JVM may reveal that almost all the weblogic.kernel.Default
threads appear to be stalled in calls like wait-for-data
or wait-for-prepare-acks
.
Workaround
Use one of the following workarounds to bypass this issue:
Set the JTA Min Threads Constraint limit of 20 or 30 on all servers in all involved clusters for the JTACoordinatorWM work manager. You can do this by using the -Dweblogic.transaction.jta.coordinator.wm.min.constraint=YYY
system property.
If the previous workaround doesn't work, set the -Dweblogic.threadpool.MinPoolSize=NNN
property on all server JVMs in a cluster to a value that is 20% higher than the current number of weblogic.kernel.Default
threads in the thread dump. If you are not sure of the number of threads in the thread dump, try 100, then 150, and so on. However, setting too many threads may cause very poor performance or even an out of memory
error. You must also note that setting MinPoolSize
to a value of 400 or above will require you to set -Dweblogic.threadpool.MaxPoolSize
to the same value, failing which the value of MinPoolSize
is ignored.
Tune applications to use fewer threads. For examples related to thread management for Message-Driven Beans (MDB), see Tuning Message-Driven Beans in Tuning Performance of Oracle WebLogic Server.
As per expected behavior, if the bean class is annotated with @Local
(or neither with @Local
nor @Remote
), and if one of the implemented interfaces is extended with the java.rmi.Remote
interface, then the interfaces should be accessed only by the local client, not by the remote client.
However, in 12.2.1, the interface can be accessed by the remote client when annotated with @Local
.
Workaround
If you want access to an EJB to be restricted to local clients only, you should avoid both of the following in the EJB implementation:
Using the @Local
annotation
Extending the java.rmi.Remote
interface
A slow trigger and a shutdown trigger can be created for the same value. Similarly, a shutdown value as well as a notify value can be created. This should be validated or prevented manually by WebLogic System Administrator while configuring RCM triggers.
This section describes the following issues and workarounds:
Starting in WebLogic Server 12.2.1, when connecting to a SQL Server named instance with a port number specified in the connection URL, the DataDirect JDBC driver for SQL Server returns the following error:
[FMWGEN][SQLServer JDBC Driver]Conflicting connection information. When the instance name is specified, it is invalid to specify the port number.
The data source fails to deploy.
Workaround
The JDBC descriptor file must either be updated to set the allowPortWithNamedInstance
property to true
, or the port number must be removed from the URL.
When a port number is specified, the WebLogic Server Administration Console automatically appends the URL with the allowPortWithNamedInstance=true
property. The WLST scripts must be updated by the administrator to set this property to true. The following sample URLs are valid:
jdbc:weblogic:sqlserver://host\\INSTANCE:1433;DatabaseName=db;allowPortWithNamedInstance=true" jdbc:weblogic:sqlserver://host:1433;DatabaseName=db" jdbc:weblogic:sqlserver://host\\INSTANCE;DatabaseName=db"
This section describes the following issues and workarounds:
If a CDI extension is observing the lifecycle events AfterBeanDiscovery or AfterDeploymentValidation, an attempt to get a javax.validation.ValidatoryFactory
bean instance will fail. For example:
public class MyExtension implements Extension { void checkValidatorFactoryBean(@Observes AfterBeanDiscovery abd, BeanManager bm) { Set<Bean<?>> validatorFactoryBeans = bm.getBeans(ValidatorFactory.class, new AnnotationLiteral<Default>() {}); if (validatorFactoryBeans.isEmpty()) { throw new RuntimeException("Container provided BeanManager doesn't contain a bean of javax.validation.ValidationFactory"); } } }
The example code above will cause a RuntimeException
because the BeanManager cannot get a ValidatorFactory bean instance. This occurs because the ValidatorFactory and Validator bean types were removed from the built-in beans starting in CDI 1.1. In CDI 1.1 and later, ValidatorFactory and Validator beans are defined by the following extension: org.hibernate.validator.internal.cdi.ValidationExtension
.
Note that when called during invocation of an AfterBeanDiscovery event observer, this method will only return beans discovered by the container before the AfterBeanDiscovery event is fired.
If an application contains both a CDI enabled EJB module and a non-CDI enabled web module, events defined with the following qualifier are not sent:
@Initialized(ApplicationScoped.class) and @Destroyed(ApplicationScoped.class)
Workaround
Place an empty beans.xml
file in the WEB-INF directory of the WAR file.
For CDI 1.0 in WebLogic Server, RAR archives are treated as CDI bean archives if the beans.xml
file is present in the META-INF directory, and the embedded library JAR classes are included as part of that bean archive. As of WebLogic Server 12.2.1, each archive, including embedded library JARs, is individually considered as a candidate bean archive based on the presence of the META-inf/beans.xml
file or at least one class with a bean-defining annotation.
Therefore, to reproduce the previous behavior, the embedded library JARs must have either a META-INF/beans.xml entry or at least one class with a bean-defining annotation.
This section describes the following issues and workarounds:
Platform: All
The security-permission
element is available in the weblogic.xml
and weblogic-ejb-jar.xml
deployment descriptors, but is not available in the weblogic-application.xml
descriptor. Therefore, in an Enterprise application, you can only apply security policies to JAR files that are EJBs or Web applications.
Platform: All
The weblogic.Deployer tool interprets any extraneous string values between command-line arguments as a file specification. For example, if you enter the command:
java weblogic.Deployer -activate -nostage true -name myname -source c:\myapp\mymodule
the tool attempts to activate a file specification named true, because the -nostage
option takes no arguments and true
is an extraneous string value.
Platform: All
The restore method does not correctly update the DConfig Bean with the plan overrides. For example, given the following steps:
DeployableObject dObject = WebLogicDeployableObject.createDeployableObject(new File(appName)); DeploymentConfiguration dConfig = WebLogicDeploymentManager.createConfiguration(dObject); dConfig.restore(new FileInputStream(new File(plan)));
the plan does not correctly override the DConfig Bean.
Workaround
Specify the plan when initializing the configuration for the application. For example:
helper = SessionHelper.getInstance( SessionHelper.getDisconnectedDeploymentManager()); helper.setApplication(app); helper.setPlan(new File(plan)); helper.initializeConfiguration();
Platform: All
When a large application file is deployed using the upload
option, the deployment task fails with the following error:
java.lang.OutOfMemoryError: Java heap space
To resolve this issue, a new system property, weblogic.deploy.UploadLargeFile
, has been added. If you see this issue, include this flag in the java
command you use to launch a deployment client.
If you are using the WebLogic Server patch releases 9.2 MP2, 9.2 MP3,10.0 MP1, 10.0 M2, 10.3, 10.3.1, 10.3.2, or 10.3.3, this flag is not needed.
Platform: Linux
If you initially deployed an application using one source file location, then attempt to redeploy the application using a new location for the source file, the deployment fails with the following exception:
New source location <new_source_file_path> cannot be configured deployed to
configured application, <application_name>. The application source is at
original_source_file_path. Changing the source location is not allowed for a
previously attempted deployment. Try deploying without specifying the source.
This is due to a WebLogic Server deployment restriction. Once you specify the source file for a deployment, you cannot change it on a redeployment.
Workaround
Undeploy the application before attempting to redeploy it using a new source file location.
Platform: All
If you create an application and deploy it to a target, and then try to deploy that same application to that same target, no relevant output message is displayed to inform you that your application is already deployed to that particular target. This occurs because when the application is deployed the second time it is considered to be the equivalent of a redeploy.
Platform: All
As of WebLogic Server 12.2.1, when deploying an application to a domain with a specified application name, if that application name is already in use in the current domain, the application deployment fails.
This is a behavior change from previous WebLogic Server versions, when specifying the same application name caused WebLogic Server to automatically derive a unique name based on the specified name.
Workaround
To avoid application deployment failure, specify unique names for all applications in a domain.
This section describes the following issue and workaround:
Platform: All
An error occurs when using the appc Maven plug-in after installing WebLogic Server Maven artifacts to the local repository using the Maven synchronization plug-in.
Workaround
WebLogic Server pub-sub libraries rely on the BEA_HOME system property to resolve compiler issues. Set the BEA_HOME system property while running appc on pub-sub applications for compilation to resolve these dependencies.
This section describes the known issues of the Domain To Partition Conversion Tool (D-PCT) and their possible workarounds:
Issue
Impacted Platforms: All
Description of the issue and when it might occur
When importing a domain, all persistent stores that are targeted to migratable targets and pointing to the same cluster must be consolidated to a single entity with distribution policy set to "Distributed" and targeted to a cluster through a virtual target. However, in 12.2.1.2.0, this consolidation fails for JDBC Stores.
As a result of this, some JDBC stores are not referenced by any of the JMS servers, SAF agents or Path Services after import. This might increase the resource usage.
Workaround
After importing a domain, delete the JDBC stores that are not referenced by any JMS Servers, SAF Agents and Path Services.
Issue
Impacted Platforms: All
Description of the issue and when it might occur
While using WLST offline for exporting a domain using D-PCT, if the MBean name contains one of the following characters, then the export of the source domain fails with an exception:
period (.)
forward slash ( / )
backward slash ( \ )
Workaround
Remove the resource from the source domain and re-create it after importing the domain archive.
Rename the resource by removing the characters that are not allowed in WLST offline mode. You can do this by editing the config.xml along with other configuration files appropriately. After modifying the MBean name, restart the source domain and before exporting the source domain ensure that the configuration change did not cause any other issue.
This section describes the following issues and workarounds:
No Available Annotation That Enables Creation of a Clusterable Timer
Extensions to the JPA Metadata Model Can Only Be Specified Via Annotations
Deserializing a JDO PersistenceManagerFactory in a Managed Environment May Fail
OpenJPA throws an exception when @Id fields are also annotated as @Unique
EJB Handle Serialization Fails When Using IIOP to Invoke 11g EJB
WebLogic Client Cannot Use IIOP to Look Up EJB 3.x Specified with Remote Annotation
Platform: All
The primary key in an Oracle table is a CHAR but the query field in the SQL table is a VARCHAR2.
Workaround
Change the database schema from CHAR to VARCHAR2. Using CHAR as a primary key is not recommended for the Oracle database.
Platform: All
There is no annotation for EJB3 beans or Ejbgen
that enables creation of a clusterable timer.
Workaround
Create a weblogic-ejb-jar.xml file and put the <timer-implementation>
element and corresponding values into the file.
Platform: All
Kodo's MappingTool cannot generate schemas for classes that use BLOBs in their primary key. BLOBs can be used in a primary key, but the schema must be defined manually. Note that support for BLOB columns in primary keys is not mandated by either the JDO or JPA specifications.
Platform: All
Extensions to the JPA metadata model can only be specified via annotations, and not via a structure similar to the orm.xml file defined by the specification.
Workaround
To specify Kodo-specific metadata for your object model, either:
use the Kodo-specific annotations, or
convert your XML-based metadata to the JDO metadata format, which does support XML specification of extensions.
Platform: All
The WebLogic Spring injection extension model doesn't support lookup method injection.
Platform: All
Deserializing a JDO PersistenceManagerFactory
in a managed environment may fail. The exception states that the javax.jdo.PersistenceManagerFactoryClass
property is missing. Note that serializing a PersistenceManagerFactory
should not generally be necessary in a managed environment.
Platform: All
Indexes declared at the class level are not always created during schema creation.
Workaround
Create the indexes manually after running the schema generation tools.
Platform: All
OpenJPA throws an exception when @Id
fields are also annotated as @Unique
in some databases. Database primary keys are unique by definition. Some databases implement this by creating a unique index on the column.
Workaround
Do not specify both @Id
and @Unique
on a single field.
Platform: All
The cache hit and miss counts may rise unexpectedly when manipulating entities without version data. The extra cache access occurs when the EntityManager closes and all contained entities are detached. Entities without version fields appear to the system to be missing their version data, and the system responds by checking their version in the cache before detachment.
Workaround
Entities with version fields or other version strategies do not cause extra cache access.
Platform: All
When using the MySQL database, and OpenJPA is configured to automatically run the mapping tool at runtime and create tables within the default schema (for example):
<property name='openjpa.jdbc.SynchronizeMappings' value='buildSchema'/>
<property name='openjpa.jdbc.Schema' value='MySQL database name' />
OpenJPA will try to create the table even if the table already exists in the database. A PersistenceException will be thrown to indicate that the table already exists and the table creation statement fails.
Workaround
To avoid this problem, if you are using the MySQL database, don't configure OpenJPA to automatically run the mapping tool at runtime and specify the default schema at the same time.
Platform: All
EJB applications that use IIOP and send JPA entities from the server to the client will fail during deserialization if the entities are Serializable (but not Externalizable) and do not declare a writeObject()
method.
Workaround
Add a writeObject()
method to such entity classes. The write object can be trivial:
private void writeObject(java.io.ObjectOutputStream out) throws IOException { out.defaultWriteObject(); }
Platform: All
When using multi-threaded processing for non-transactional topic Message-Driven Beans (MDBs) that specify a foreign topic (non-WebLogic) JMS, the MDB container can fail to provide reproducible behavior. For example, if a runtimeException
is thrown in the onmessage()
method, the container may still acknowledge the message.
Workaround
Set the max-beans-in-free-pool
attribute to 1
in the deployment descriptor.
Platform: All
As described in the Enterprise JavaBeans Specification, the remote home interface allows a client to obtain a handle for that remote home interface. The handle can be serialized and written to stable storage. Later, possibly in a different JVM, the handle can be deserialized from stable storage and used to obtain a reference to the remote home interface.
However, when a servlet hosted on WebLogic Server 12.2.1 (and later) uses the IIOP protocol to look up the remote home interface of an EJB hosted on Oracle WebLogic Server 11g, serialize the handle to a file, and then deserialize the handle from the file, the deserialization may fail with a ClassNotFoundException
.
The situation also applies to an EJB hosted on WebLogic Server 11g that attempts to use IIOP to invoke an EJB hosted on WebLogic Server 12.2.1 (and later).
Workaround
Use the T3 protocol instead of IIOP.
Platform: All
When an application using the WebLogic standard client (wlclient.jar
) uses the IIOP protocol to look up the remote home interface of an EJB 3.x bean that has been decorated with the @Remote
annotation, the lookup may fail with a ClassNotFoundException
.
Workaround
You can do either of the following:
In the client classpath, use the WebLogic Install client, weblogic.jar
, instead of the WebLogic standard client, wlclient.jar
.
Create the remote home interface of the EJB by extending the java.rmi.Remote
interface instead of using the @Remote
annotation.
There are no known Examples issues in this release of WebLogic Server.
This section describes the following issues and workarounds:
Platform: All
The HTTP Publish/Subscribe server does not support authentication and authorization of the local client. The local client has full permissions to operate on channels of the HTTP Publish/Subscribe server, which means the local client can create/delete channels and publish/subscribe events from channels.
This section describes the following issue and workaround:
Platform: All UNIX
The installer does not verify whether sufficient disk space is available on the machine prior to completing the installation. As a result, if an installation cannot be completed due to insufficient space, the installer displays the following error message and exits:
Fatal error encountered during file installation. The installer will now cleanup and exit!
Workaround
If this problem occurs, restart the installer using the following command:
server103_linux32.bin -log=log.out -log_priority=debug
The preceding command generates a log of the installation procedure, providing details about the exact cause of the failure. If the cause is indeed insufficient space, the log file indicates it explicitly.
When installing Oracle WebLogic Server 12.2.1 on Mac OS X development systems, some recommended JDBC driver fixes for production environments are not included with the Oracle JDBC thin driver that is included with the installation.
Workaround
A patch or patch(es) will be made available on My Oracle Support for developers wishing to incorporate these fixes on development environments.
During the server shutdown when executing rollouts, if the server enters the FAILED state, you may encounter the following error:
Workflow wf0008 failed and the revert process was not initiated. The failure was: Failure performing execute of wf0008-3-1-0 (ShutdownServerResumeOnRevertCommand), caused by Failed to shut down server server1: java.lang.Exception: The process for the server server1 has not completely shut down. This problem should be reported and you may have to kill the process manually.
This error is encountered when using WLST or the Administration Console.
Workaround
You must check the server logs carefully to determine the reason for the server failure which led to shutdown failure. You can continue the rollout after resolving the issue and manually shutting down the server.
Due to incompatibility between the ONS (Oracle Notification Services) and the UCP (Universal Connection Pool) jars that are packaged with WebLogic Server 12.2.1.1, the Active GridLink data source deployments are affected as some data sources stop receiving database FAN events.
Workaround
The ONS jar packaged with WebLogic Server 12.2.1.1 requires a patch. You can contact My Oracle Support for the patch.
In the Zero Downtime (ZDT) patching scenario, when the rollout in progress involves JMS service migration with a case of failback, the JMS T3 standalone clients are unable to perform JNDI look up for the connection factory and destination objects on the JMS server.
Workaround
When the migrated service fails back to the original server, the JMS standalone clients must wait for nondeterministic time till the JNDI looked up successfully.
This section describes the following issues and workarounds:
FastSwap May Relax the Access Modifiers of Fields and Methods
FastSwap Does Not Support Redefinition of the Entity Bean and ejbClass
Classpath Order Is Not Guaranteed When There Are Multiple JARs in an EAR File
No Library is Loaded if the library-directory Element is Empty
Disable Implicit CDI Scanning When Migrating Java EE 6 Applications to Java EE 7
Platform: All
FastSwap may relax the access modifiers of fields and methods. Private and protected members may be made public at runtime. This changes the behavior of reflection and may affect reflection-based frameworks such as Struts.
Platform: All
FastSwap does not support redefinition of the Entity bean and ejbClass (Session/MDB). Therefore, any updates to entity classes will cause redefinition errors.
Workaround
After updating an entity class, redeploy the application.
Platform: All
When you have an EAR file containing separate JAR files, and two or more of those JAR files have a class with the same name, it is not possible to predict from which of those JAR files WebLogic Server will instantiate the class. This is not an issue if the classes are the same, but if they are different implementations, the results are unpredictable.
Workaround
Currently there is no known workaround for this issue.
Platform: All
FastSwap is not supported when using CDI. If you deploy an application in exploded format with FastSwap enabled, this deployment fails and errors related to CDI occur.
Platform: All
The Java EE 7 specification (https://jcp.org/en/jsr/detail?id=342
) states that an empty library-directory
element may be used to specify that there is no library directory.
In previous releases of WebLogic Server, an empty library-directory
element in an application.xml
file, as shown below, resulted in the library JAR files in the root directory of an EAR file being loaded as libraries:
<library-directory></library-directory>
As of WebLogic Server 12c (12.2.1.1) this behavior was changed to adhere to the Java EE 7 specification. Now, if an empty library-directory
element exists in the application.xml
file, no library is loaded from the application root, the lib
directory, or a shared library.
Note:
If you create an empty directory in the application and point the library-directory
element to that directory, you can load libraries from shared libraries (but not libraries from the lib
directory) without removing libraries from the lib
directory.
When migrating existing applications to WebLogic Server 12.2.1.1, the deployment performance of applications developed using Java EE 6 (or prior Java EE versions) may be adversely affected by changes to default CDI scanning required by Java EE 7.
Workaround
To improve deployment performance for applications developed on previous Java EE versions, you can disable implicit CDI scanning in Java EE 7 by setting implicit-bean-discovery-enabled
to false
by:
Using the WebLogic Server Administration console, go to the Domain General Configuration page, in the Advanced Setting Sections, and deselect Enable Implicit Bean Discovery.
Using WLST online or offline.
To change this setting using WLST online, enter the following commands:
connect('user','password','url') domainConfig() edit() cd('CdiContainer/mydomain') startEdit() set('ImplicitBeanDiscoveryEnabled',0) // 1 to enable 0 to disable validate() save() activate(block="true")
To change this setting using WLST offline, enter the following commands:
readDomain(domain) create('mydomain','CdiContainer') cd('CdiContainer/mydomain') set('ImplicitBeanDiscoveryEnabled',0) // 1 to enable 0 to disable updateDomain() closeDomain()
This section describes the following issues and workarounds:
Platform: All
Oracle WebLogic Server 12.1.2 supports JDK 7 for execution of server applications, and JDK 6 and JDK 7 for WebLogic Server 12.1.2 clients connecting to WebLogic Server 12.1.2 servers. Oracle JRockit is not supported for execution of WebLogic Server 12.1.2 and later server applications. For more information, see Supported Configuration in What's New in Oracle WebLogic Server 12.2.1.2.0.
This section describes the following issues and workarounds:
Exception When Multiple Producers Use the Same Client SAF Instance
Multi-byte Characters are not Supported in Store File and Directory Names
Testing Abrupt Failures of WebLogic Server When Using File Stores on NFS
Custom Domain Template Upgrade May Result in Lost Topic Messages or Deplete Server Memory
Set System Properties for Interoperability with Existing JMS .NET Clients
JMS Distributed Destinations Are Not Present After Extending a Domain
Using JBoss 5 as a Foreign Provider for a JMS Messaging Bridge Causes Issues
Platform: All
This issue may occur if you are using an EJB or servlet with resource reference to a JMS Connection Factory, that is, when a connection factory is obtained using an @Resource annotation or a context lookup of a resource defined in an application's XML descriptor, and if this resource reference does not explicitly specify a JNDI name via a lookup attribute, a mappedName attribute, or a jndi-name in a descriptor file.
In WebLogic Server 12.2.1 and later releases, the Java EE 7 Platform Specification mandates a change that can cause such resource references to unexpectedly return a Platform Default Connection Factory instead of either returning a connection factory from JNDI with a JNDI name that matches the resource name, or returning a javax.naming.NameNotFoundException
. Following are some of the possible symptoms of this change in behavior of unmapped connection factory resources:
An INFO level log message indicating that an application has been given a default connection factory though it might have required a custom connection factory instead. For example,
BEA-169827> <The resource reference "jms/my_cf" of type JMS Connection Factory in application "my_module" does not specify a JNDI name. As of Java EE 7 and WebLogic version 12.2.1.1, such references return a "java:comp/DefaultJMSConnectionFactory" by default when no Connection Factory with a JNDI name that matches the resource name is found.>
An application stops delivering customized behavior that is expected from a custom configured WL JMS connection factory, such as a default message expiration.
Errors, such as Illegal Destination type
, which may occur while attempting to use an AQ JMS destination with a WebLogic JMS connection factory.
Exceptions such as Destination not found
or Dispatcher not found
.
Temporary destination is created on a local JMS Server instead of a JMS Server that is hosted in the same cluster as the intended connection factory.
Workaround
To ensure that applications work as expected, we recommend one of the following workarounds:
Explicitly configure the system to force old behavior by setting the WebLogic Server JMSConnectionFactoryUnmappedResRefMode
configurable to the FailSafe mode. Note that this setting is compliant with the Java EE 7 specification although Java EE 7 mandates that this setting cannot default to the FailSafe mode. For more information, see Specifying the Unmapped Resource Reference Mode for Connection Factories in Administering JMS Resources for Oracle WebLogic Server.
Examine and fix all unmapped resource reference in all servlets and EJB applications to make them explicitly specify their desired connection factory. If the desired connection factory is Java EE 7 default connection factory, then you can specify java:comp/DefaultJMSConnectionFactory
as the JNDI name.
Platform: All
Deployment descriptor validation fails when descriptor validation is enabled, and an EAR file contains only JMS modules.
Workaround
Make sure that there is at least one Java EE specification-compliant module in the EAR.
Platform: All
When multiple JMS producers use the same JMS Client SAF instance (within a single JVM), depending on the timing of the JMS SAF client creation, you might receive the following exception:
Error getting GXA resource [Root exception is weblogic.jms.common.JMSException: weblogic.messaging.kernel.KernelException: Error getting GXA resource]
Workaround
When using multiple JMS SAF client producers, try introducing a small delay between the creation of each new client.
Platform: All
There is no support for multi-byte characters in WebLogic Store file and directory names. For instance, when the WebLogic Server name has multi-byte characters, the default store cannot be created, and WebLogic Server will not boot.
Workaround
Create WebLogic Server instances without multi-byte characters in the path name and use that path name for the default store configuration. Do not use multi-byte characters in the WebLogic Server name.
Platform: All
Oracle strongly recommends verifying the behavior of a server restart after abrupt machine failures when the JMS messages and transaction logs are stored on an NFS mounted directory. Depending on the NFS implementation, different issues can arise post failover/restart. For more information, see Section 6.3, "Testing Abrupt Failures of WebLogic Server When Using File Stores on NFS."
Issue
Workaround
Impacted Platforms: All
As of WebLogic Server 12.1.2, JMS server and WebLogic store targeting in the Configuration Wizard has changed.
In 12.1.2, the Configuration Wizard automatically targets JMS servers and WebLogic stores to migratable targets when these objects are not explicitly targeted to a Managed Server or a cluster in a domain template. Using migratable targets is a best practice that enables high availability for the JMS system.
If you use a custom domain template to create domains in WebLogic Server 12.1.2, and that template includes JMS servers and WebLogic stores that are not explicitly targeted to a Managed Server or a cluster, targeting results differ from previous releases.
This change in behavior also results in a change to durable topic subscriptions for message-driven beans (MDBs) that enable the generate-unique-client-id
extension. When WebLogic Server creates durable topic subscriptions for such an MDB, it changes the subscription name to include the migratable target name. Messages stored under the original subscription names are not delivered to the MDB, and the original subscriptions continue to accumulate new messages.
When planning your upgrade, note the following important changes:
If you follow the instructions in Upgrading Oracle WebLogic Server and use the Reconfiguration Wizard to reconfigure your existing pre-12.1.2 domain, the configuration and durable topic subscriptions remain intact.
If you regenerate your domain using a custom template, as described above, the resulting configuration differs from previous releases and new durable topic subscriptions are created when the system is started. However, old durable topic subscriptions remain. Those subscriptions contain unprocessed messages that continue to accumulate messages, depleting server memory.
Choose one of the following recommended workarounds:
Use the Reconfiguration Wizard to upgrade the domain in place.
Drain messages before upgrading or regenerating the domain configuration. After upgrading, use the WebLogic Server Administration Console to search and delete old JMS subscriptions.
Delete JMS file store files or JMS JDBC store tables. All messages persisted in the file or table is deleted.
Platform: All
To enable JMS .NET clients developed prior to WebLogic Server 12.1.3 to interoperate with WebLogic Server 12.1.3, set the following system property on your WebLogic Server 12.1.3 instances:
-Dweblogic.protocol.t3.login.replyWithRel10Content=true
The default value is false
for interoperability with existing JMS .NET clients developed prior to WebLogic Server 12.1.3.
Platform: All
After extending a domain using an extension template that was generated from a domain that contains JMS distributed destinations, the distributed destinations are not present in the domain. This impacts the following distributed destinations:
distributed-queue
distributed-topic
uniform-distributed-queue
uniform-distributed-topic
If any of these elements are contained in the JMS XML files in the source template, they are not processed and are not configured in the destination domain.
Workaround
To resolve this, use the following sequence of WLST commands, either interactively or in a script:
readDomain('domain_path') addTemplate('extension_template_file') unassign('JmsSystemResource','resource_name','Target','destination_name') For example: unassign('JmsSystemResource','JMSModule','Target','C1') assign('JmsSystemResource','resource_name','Target','destination_name') For example: assign('JmsSystemResource','testModule','Target','Server-1') unassign('JmsSystemResource','resource_name','Target','destination_name') For example: unassign('JmsSystemResource','testModule','Target','Server-1') assign('JmsSystemResource','resource_name','Target','destination_name')For example: assign('JmsSystemResource','testModule','Target','C1') updateDomain() closeDomain()
Platform: All
When creating a JMS messaging bridge using JBoss 5 as a foreign provider, conflicting versions of the same class are loaded. This causes the bridge to fail during startup.
Workaround
Oracle recommends that you upgrade to JBoss 7 to avoid this issue.
This section describes the following issue and its workaround:
When the transaction protocol for a data source is changed, it is necessary to restart all targeted servers in order to avoid inconsistent transaction outcomes.
Issue
<Warning> <JTA> <BEA-111020> <An issue occurred during cross-site recovery processing: PeerSiteRecoveryLeaseMaintenance: Unable to create either connection or prepared statements for cross-site recovery..>
Workaround
You can work around this issue by using domain logging filter.
This section describes the following issues and workarounds:
Platform: All
Due to a known Sun Microsystems VM bug (513552), a 1.4 Thin Client Applet cannot contact WebLogic Server 9.0 or later. This is because the VM does not distinguish correctly between a client and a server connection. The VM creates a server-type connection and caches it. It then attempts to make a client-type connection, finds the cached connection and tries to use that, but then encounters an error because clients are not allowed to use server connections.
Platform: RedHat Linux
Applications that run on RedHat (RH) Linux and that also directly or indirectly use system time calls may experience intermittent time issues if the ClockSource
is set to tsc
(the default). The standard POSIX C gettimeofday()
call, and consequently also the Java System.currentTimeMillis()
and java.util.Date()
calls can intermittently return a value that is approximately 4400 seconds in the future, even in a single-threaded application.
This issue is not unique to WebLogic or Java, but applies to any application running on RH Linux. Issues can occur for applications that either explicitly make a time call using standard Java, or explicitly by using any time-based application server services.
Possible symptoms include, but are not limited to, premature transaction timeouts, unexpected expiration of JMS messages, and incorrectly scheduled timers.
This issue was fixed in RedHat 5.3.
Platform: Linux
The JRockit JVM appears to freeze when doing long array copies as part of unlimited forward rolling. This can happen when multiple server reboots occur due to Out Of Memory
conditions.
Workaround
When booting the servers, include the following JRockit JVM flag:
-XXrollforwardretrylimit:-1
Platform: Linux
A Serial Version UID Mismatch issue is encountered if you deploy an application on a latest JVM, but compiled with previous Service Release of IBM Java 6 JDK.
Workaround
To be compatible with the serialization of previously compiled applications, modify the WL_HOME
/common/bin/commEnv.sh
file to include the following command:
JAVA_OPTIONS="$JAVA_OPTIONS -Dcom.sun.xml.namespace.QName.useCompatibleSerialVersionUID=1.0"
Alternatively, you can use the command line option:
export IBM_JAVA_OPTIONS= "-Dcom.sun.xml.namespace.QName.useCompatibleSerialVersionUID=1.0"
If you intend to deploy new applications with previously compiled applications, they must be recompiled as necessary to have the same Serial Version UID.
Platform: Linux
You might encounter a JVM stack overflow error or exception while running WebLogic Server. This issue applies to Oracle Enterprise Linux 4, 5, 5.1 on AMD64 and 64-bit Xeon platforms.
Workaround
Increase the stack size from the default 128k to 256k.
This section describes the following issues and workarounds:
When packing a domain that has been configured to use Lifecycle Manager in one environment using the pack
command, and unpacking it in another environment, the plugin paths contained in the<Domain>/config/lifecycle-config.xml
file may still reference the Oracle Home directory paths from the source environment.
Workaround
Rectify the file paths in the lifecycle-config.xml
file to reflect the Oracle Home directory paths in the target environment.
In an integrated environment involving Weblogic Server, Oracle Traffic Director (OTD), and Lifecycle Manager, if the out of band functionality of Lifecycle Manager is enabled then the expectation is that any change in resource groups including targeted changes to domain partitions will be sent to OTD using Lifecycle Manager. However, as of 12.2.1, this behavior has changed; the updates to resource groups, including adding or deleting a resource group, are not being sent to OTD.
Workaround
You must restart the domain partition after targeting configuration changes. This ensures that OTD is updated with the latest configuration changes in resource groups.
This section describes the following issue and workaround:
Platform: All
The @unharvestable
tag is not being honored at the interface level. If MBean attributes are not explicitly marked as @unharvestable
, they are considered to be harvestable and will appear as harvestable in the WebLogic Server Administration Console.
Workaround
You can explicitly mark MBean attributes as @unharvestable
.
Platform: All
When specifying a wildcard pattern in a variable for a watch rule expression that matches custom MBean ObjectName patterns, ensure that the pattern is sufficiently explicit. If you exclude an MBean type name and use an ambiguous instance pattern, the following may result:
Only WebLogic Server runtime MBean instances are matched to the pattern.
The desired custom MBean instances are ignored.
For example, the following ObjectName pattern does not explicitly declare a type and uses an ambiguous ObjectName pattern that can match a WebLogic Server runtime MBean instance:
${ServerRuntime//com.b*:Type=Server*,*}
Workaround
To avoid confusion, use a sufficiently explicit ObjectName pattern, or declare the MBean type in the variable expression.
Platform: All
This issue is related to a change in how WLDF uses the module name for harvester records and watch rule notifications. The internal descriptor name is now overridden to use the name that is provided when the external WLDF descriptor is registered through the Runtime Control API or WLST functions. You will notice this if you have been using the Runtime Control feature to deploy external WLDF system resources to gather Harvester metrics, or listen for a Watch rule notification based on the deployed module.
For example, if the Harvester and Watch elements in your deployed descriptor resemble the following:
<harvester> <name>MyExternalResource</name> ... <watch-notification> <name>MyExternalResource></name> ...
and you register this descriptor with the runtime control as createSystemControl("resource1", ...)
, previously harvester data would have been recorded using MyExternalResource
as the WLDFMODULE
column value for Harvester records in the archive for this resource. It would also be used for the module name in the Watch Notification payloads. Now, resource1
would be used for the WLDFMODULE
name in the harvester records and watch and notification payloads.
Workaround
Use the name the external WLDF resource was registered with when using the WLST command createSystemResourceControl()
. Additionally, any notification listeners for Watch notifications from an external resource that are dependent on the WLDF module name in the notification payload should be looking for the name the control was registered with.
For example, if you register your control as createSystemResourceControl("resource1", ...)
then the WLDF Accessor queries for this resource should include the module name as WLDFMODULE='resource1'
in the query string.
Platform: All
If you configured the WLDF archive for servers in a domain to use an Oracle EBR editioned schema, and attempt to upgrade that schema using Upgrade Assistant, it is possible that some errors may occur in servers that are still running against that schema when the upgrade is performed.
This is relevant in the following conditions:
WLDF schemas installed to an Oracle EBR database using the 12.1.2 Repository Creation Utility (RCU) or manually created WLDF schemas from an earlier version of WebLogic Server
When using the Upgrade Assistant, the user chooses to upgrade the existing schema to use Oracle EBR editioned tables
There are servers running while the upgrade is performed (for example, if the schema is shared across multiple WebLogic Server domains)
During the upgrade, the WLDF tables are renamed and edition-based views are created to point to the renamed instances. No data is lost in this operation. However, in these situations, there may be a brief period where some errors can occur (during the time while the upgrade is performed) in the running servers when recording WLDF Harvester or Instrumentation data.
These errors are not critical and should not affect server performance, but may result in a lost of a small amount of monitoring data for those servers.
Workaround
To avoid the potential of this occurrence, you can halt the affected WebLogic Server domain(s) during the Oracle Database upgrade process.
This section describes the following Node Manager issue and workaround:
Platform: Linux
On some specific Linux platforms and versions, there is an issue removing a virtual interface/alias dynamically. Removing the virtual interface that is the primary address of the interface may result in other secondary virtual IP addresses being removed at the same time. This may lead to random exceptions occurring with Node Manager during server migration. If you have this issue, you may occasionally find exceptions in the Node Manager log file when shutting down a server after migration. For example, you may receive the following error:
java.io.IOException: Command '/<PATH to DOMAIN>/bin/server_migration/wlsifconfig.sh -removeif -IPv4 eth0 X.X.X.X returned an unsuccessful exit code '1'
.
Here is an example of the issue:
First, add three virtual interfaces, with the first one being the primary:
$ sudo /sbin/ifconfig eth0:4 X.X.X.178 netmask 255.255.248.0 $ sudo /sbin/ifconfig eth0:5 X.X.X.179 netmask 255.255.248.0 $ sudo /sbin/ifconfig eth0:6 X.X.X.180 netmask 255.255.248.0 $ sudo /sbin/ifconfig eth0:4 down
When removing the primary (first one in list), the other two will be automatically removed at the same time.
Workaround
To fix this issue temporarily, use the following command to enable the promote_secondaries
flag on your network interface. Replace eth0
with your actual interface name:
$ sudo /sbin/sysctl net.ipv4.conf.eth0.promote_secondaries=1
You can also use the following command to update the default setting for all interfaces:
$ sudo /sbin/sysctl net.ipv4.conf.all.promote_secondaries=1
If this is enabled and the primary address of an interface gets deleted, a secondary interface will be upgraded to become the primary interface. The default is to purge all the secondary interfaces when you delete the primary interface.
To permanently remedy this issue after server reboot, update the sysctl.conf
file. For example:
$ echo "net.ipv4.conf.eth0.promote_secondaries=1" >> /etc/sysctl.conf
Platform: HPUX IA64
There is a fundamental difference between Node Manager starting a server using a start script and Node Manager starting a server using the Java command. When using the start script, the -d64 flag is added based on some script language that detects the platform. Node Manager does not add this flag when starting a server with the Java command.
Workaround
When starting a server using Node Manager through the Java command, specify arguments such as -d64 in the ServerStart
arguments field.
Platform: All
In rare cases, Oracle HTTP Server (OHS) instances that are managed by WebLogic Server may start in state UNKNOWN
. This can occur if the Administration Server is unable to initialize the state of the OHS instance, for example, if Node Manager is not running at the time the OHS instance is created and if you connect directly to Node Manager and bypass the Administration Server when checking the state for the first time.
Workaround
Continue to use the Administration Server. The state of the OHS instance should be properly initialized.
Platform: MS Windows
The OPSS template information that is necessary to start Node Manager using installNodeMgrSvc.cmd
is missing. As a result, installNodeMgrSvc.cmd
cannot be used correctly in a JRF/OPSS environment. Node Manager will start without the information used to specify the correct classes to load KSS and will use JKS as the default keystore. You will notice this problem when you are setting up your environment and first run startNodeManager.cmd
, which will load KSS.
Workaround
Edit the installNodeMgrSvc.cmd
command before using it, copying the section from startNodeManager.cmd
. For example:
set JAVA_OPTIONS=%JAVA_OPTIONS% -Doracle.security.jps.config=C:\OracleHome11g\user_projects\domains\mydomain\config\fmwconfig\jps-config-jse.xml -Dcommon.components.home=C:\OracleHome1213\Oracle_Home\oracle_common -Dopss.version=12.1.3 if NOT "%POST_CLASSPATH%"=="" (set POST_CLASSPATH=C:\OracleHome1213\Oracle_Home\oracle_common\modules\oracle.jps_12.1.3\jps-manifest.jar;%POST_CLASSPATH%) else (set POST_CLASSPATH=C:\OracleHome1213\Oracle_Home\oracle_common\modules\oracle.jps_12.1.3\jps-manifest.jar)
Platform: All
WLST offline, as well as the pack
and unpack
commands, do not support setting the following new Node Manager replacement properties that were introduced in WebLogic Server 12.1.3.
Deprecated Property | Replacement Property |
---|---|
|
|
|
|
|
|
|
|
|
Use |
|
|
|
|
|
|
|
|
|
|
Workaround
If you configure Node Manager properties using WLST offline, or the pack
and unpack
commands, you must continue to use the preceding deprecated properties, which remain fully supported in WebLogic Server. For more information, see Node Manager Properties in Administering Node Manager for Oracle WebLogic Server.
There are no known Operations, Administration, and Management issues in this release of WebLogic Server.
Platform: MS Windows 2000
When trying to persist an empty byte array field within an entity to a Sybase or Oracle database, the value gets stored as a NULL rather than as bytes. As a result, when retrieving the value, NULL is returned.
This is a limitation of the Sybase and Oracle drivers, which convert the empty byte array to a NULL while storing it in the database. The issue happens with WebLogic JDBC drivers as well as the proprietary Sybase and Oracle drivers.
This section describes the following issue for various WebLogic Server plug-ins:
Platform: All
Under the following circumstances, the IIS plug-in may not work, resulting in an apr_socket_connection
error:
Both the IIS and WebLogic Server instances are on the same machine.
IPv6 is enabled on the machine, but the machine is not in an IPv6 environment (that is, the IPv6 interface is enabled but is not working).
The listen address of the WebLogic Server instance is set to the simple host name.
Either the directive WebLogicHost or WebLogicCluster is set to the simple host name for the IIS instance.
Platform: All
Introspection fails and users receive an error when they try to introspect a domain that they cannot write into.
Workaround
Change the permissions on the domain root directory to allow the user that executes the introspect.
Platform: All
In Oracle Virtual Assembly Builder (OVAB) Studio, HTTP proxying is disabled. You can use a system property to enable HTTP proxy detection.
You can set this system property for each execution of a Studio launch, or permanently by modifying the abstudio.sh
file.
To set the property for a single execution of OVAB Studio:
Shut down OVAB Studio.
Remove the configuration directory:
$AB_INSTANCE/state/gui/$USER/system.12.1.2.0.0
(or equivalent)
Restart the GUI with the property set to some value, for example 1:
./abstudio.sh -J-Dovab.studio.enableHttpProxy=1
You must define the property in every ensuing execution of the GUI or the property setting in abstudio.sh
will force proxying back to false.
To set the property to consistently enable HTTP proxying:
After setting enableHTTPProxy=1
, you can set the proxy host, port, and exceptions using the standard Java properties http.proxyHost
, http.proxyPort
, and http.nonProxyHosts
. If you are using a nonstandard desktop environment on Linux, you may need to set the http_proxy
property with the valuehost:port
.
There are no known Protocols issues in this release of WebLogic Server.
This section describes the following issue and workaround:
Platform: All
Calls to the Ant version 1.7 rmic
task automatically add a -vcompat flag
, which is not compatible with rmic
for Oracle WebLogic Server.
Workaround
Use either of the following workarounds if your rmic call is of the form:
rmic classname="com.bea.crmsimulation.legacyra.LegacyAdapter" base="${module_location}/core-legacy-ra/classes" classpath="${core.classes}" compiler="weblogic" />
Add a stubversion
<rmic classname="com.bea.crmsimulation.legacyra.LegacyAdapter" base="${module_location}/core-legacy-ra/classes" classpath="${core.classes}" compiler="weblogic" stubversion="1.2"/>
Remove the compiler
flag
<rmic classname="com.bea.crmsimulation.legacyra.LegacyAdapter" base="${module_location}/core-legacy-ra/classes" classpath="${core.classes}"
Platform: All
When a client invokes an EJB that is hosted in a WebLogic 12.1.2 domain configured to run in production mode, any invocation failure results in a truncated Java exception stack trace returned to the client.
Workaround
In the Java command that starts WebLogic Server, specify the following option:
-Dweblogic.PrintStackTraceInProduction=true
This section describes the following issues and workarounds:
BAD_MAC_RECORD Error Occurs When Using JSSE-based SSL Provider
StoreBootIdentity Works Only if the Appropriate Server Security Directory Exists
Authentication Failure After Upgrading a Domain From WLS 6.1
Random Number Generator May Be Slow on Machines With Inadequate Entropy
Use of WebLogic SAML Support For SSO is Not Supported in Partitions or With Security Realm Restart
Compatibility Realm Domains Are Not Supported by WebLogic 12.2.1.1 Clients
Platform: All
Service-side Kerberos authentication fails with an HTTP/1.1 Error 401 Unauthorized
if the JDK version is JRockit 1.60_24, 1.60_28, or 1.60_29.
Workaround
Use one of the following workarounds:
Instead of using ktab.exe
to generate the keytab file, use another tool such as kadmin
to generate it.
Use ktab.exe
to manually supply the correct kvno.
Platform: All
If WebLogic Server is configured to use the JSSE-based SSL provider, attempts to create an SSL connection may fail with a BAD_MAC_ERROR
message.
Workaround
Install JDK 7u2 or higher and restart WebLogic Server.
Platform: All
The option -Dweblogic.system.StoreBootIdentity
works only if the appropriate server security directory exists. This directory is usually created by the Configuration Wizard or upgrade tool.
However, the appropriate server security directory could be absent in domains checked into source-control systems.
Platform: All
A WebLogic Server instance can experience a boot time failure with a SecurityServiceException
when the RDBMS Security Data Store is configured for a DB2 database using the DB2 driver supplied with WebLogic Server.
Workaround
When RDBMS Security Data Store is using the AlternateId
connection property for a DB2 database, you must also set the additional property BatchPerformanceWorkaround
as true
when using the DB2 driver supplied with WebLogic Server.
Platform: All
After upgrading a domain from WLS 6.1, the WebLogic Server instance will not boot due to an authentication failure.
Workaround
A system user password must be set up in the WLS 6.1 domain before or after the upgrade process in order for the WebLogic Server instance to boot properly.
Platform: All
After you configure either the Identity Provider or Service Provider services for SAML 2.0 and attempt to publish the SAML 2.0 services metadata file, an InvalidParameterException
message may be generated and displayed in the WebLogic Server Administration Console.
Workaround
When configuring the SAML 2.0 federation services for a WebLogic Server instance, be sure to enable all binding types that are available for the SAML role being configured. For example, when configuring SAML 2.0 Identity Provider services, you should enable the POST, Redirect, and Artifact bindings. When configuring SAML 2.0 Service Provider services, enable the POST and Artifact bindings. Optionally, you may choose a preferred binding.
Platform: All
When configuring SAML 2.0 Service Provider services, enabling both the Force Authentication and Passive attributes is an invalid configuration that WebLogic Server is unable to detect. If both these attributes are enabled, and an unauthenticated user attempts to access a resource that is hosted at the Service Provider site, an exception is generated and the single sign-on session fails.
Note that the Force Authentication attribute has no effect because SAML logout is not supported in WebLogic Server. So even if the user is already authenticated at the Identity Provider site and Force Authentication is enabled, the user is not forced to authenticate again at the Identity Provider site.
Avoid enabling both these attributes.
Platform: All
If the WebLogic Full Client is running in a non-forked VM, for example by means of a <java>
task invoked from an Ant script without the fork=true
attribute, the following error might be generated:
java.lang.SecurityException: The provider self-integrity check failed.
This error is caused by the self-integrity check that is automatically performed when the RSA Crypto-J library is loaded. (The Crypto-J library, cryptoj.jar
, is in the wlfullclient.jar
manifest classpath.)
This self-integrity check failure occurs when the client is started in a non-forked VM and it uses the Crypto-J API, either directly or indirectly, as in the following situations:
The client invokes the Crypto-J library directly.
The client attempts to make a T3S connection, which triggers the underlying client SSL implementation to invoke the Crypto-J API.
When the self-integrity check fails, further invocations of the Crypto-J API fail.
Workaround
When running the full client in a <java>
task that is invoked from an Ant script, always set the fork
attribute to true
.
For more information about the self-integrity check, see "How a Provider Can Do Self-Integrity Checking" in How to Implement a Provider in the Java™ Cryptography Architecture, available at the following URL:
Platform: Linux
In order to generate random numbers that are not predictable, SSL security code relies upon "entropy" on a machine. Entropy is activity such as mouse movement, disk IO, or network traffic. If entropy is minimal or non-existent, then the random number generator will be slow, and security operations may time out. This may disrupt activities such as booting a Managed Server into a domain using a secure administrator channel. This issue generally occurs for a period after startup. Once sufficient entropy has been achieved on a JVM, the random number generator should be satisfied for the lifetime of the machine.
For further information, see Sun bugs 6202721 and 6521844 at:
http://bugs.sun.com/bugdatabase/view_bug.do?bug_id=6202721
http://bugs.sun.com/bugdatabase/view_bug.do?bug_id=6521844
Workaround
On low-entropy systems, you can use a non-blocking random number generator, providing your site can tolerate lessened security. To do this, add the -Djava.security.egd=file:///dev/urandom
switch or file://dev/./urandom
to the command that starts the Java process. Note that this workaround should not be used in production environments because it uses pseudo-random numbers instead of genuine random numbers.
Platform: All
BEA-090402
is a catalog message that explains what to do if a server instance fails to boot due to a problem with the boot.properties
file.
However, the real issue is an authentication problem. BEA-090402
is just describing the most likely root cause, which is that the customer has modified the boot.properties
file or the boot user password and thus authentication fails.
There are other causes for this failure that are less obvious. For instance, there could be an LDAP corruption, a disk failure, or a Managed Server may fail to connect to the Administration Server and falls back to authenticating on its local LDAP which is out of date. These causes are not mentioned in BEA-090402
. If you are positive that you are not having a credential issue, BEA-090402
may indicate one of these other, less common causes.
The WebLogic Server LDAP Authentication provider log messages show an incorrect URL for the LDAP connection returned by the getConnection
method. The getConnection
messages indicate that SSL is used, even if you did not specify SSL in the WebLogic Server provider configuration.
Workaround
The "Connecting to host" messages in the log file do correctly indicate whether SSL is used. For example,
<Connecting to host=somehost, port=3060>
<Connecting to host=somehost, ssl port=3060>
When starting an ODI Managed Server, the identity used to start the Managed Server is not mapping properly to the WebLogic Sever Administrator role, causing security errors. If these warnings are seen while starting the Managed Server, the embedded LDAP files from the Managed Server are causing a resynchronization of the policy from the Administration Server.
Workaround
Remove the embedded LDAP files in the folder <domain>/…/data/ldap/ldapfiles
from the Managed Server and restart the Managed Server.
Platform: All
Using SAML 1.1 and SAML 2.0 for single sign-on with web browsers and HTTP clients is not supported in partitions or for automatic realm restart.
However, the use of SAML 1.1 and SAML 2.0 with web services is fully supported with these features.
Platform: All
In WebLogic Server version 12.2.1.1, support for Compatibility security, including compatibility realms, has been removed. For more information about Compatibility security and compatibility realms, see What Is Compatibility Security? in Administering Security for Oracle WebLogic Server 12.1.3.
The 6.x realms were deprecated in WebLogic Server version 9.0 (November 2006). WebLogic domains configured with realm adapter security providers and 6.x realm configuration elements are no longer supported in WebLogic Server 12.2.1.1. For information about the specific Compatibility security and 6.x realm components removed and no longer supported in WebLogic Server 12.2.1.1, see Removed Functionality and Components in What's New in Oracle WebLogic Server 12.2.1.2.0.
In addition, WebLogic Server 12.2.1.1 clients, or servers acting as a client, can no longer invoke on servers if the target domain is configured with a compatibility realm. Such an invocation throws a ClassNotFoundException (RealmAdapterUser)
and the invocation fails.
Interoperability between WebLogic Server 12.2.1.1 and with prior release servers is supported if compatibility realms are not configured. See Protocol Compatibility in Understanding Oracle WebLogic Server.
In WebLogic Server 12.2.1.1, the default authorization and default role mappings have changed. The role mappings have changed to include identity domains. For example, the default role mapping for the WebLogic Sever Administrator role has changed from Group(Administrators) to AdminIDDGroup(Administrators) in order to support identity domains.
If you try to create a partition in a domain after upgrading the domain, then the partition creation fails. This is because the domain is validated to check if every security realm contains the new policies and predicates. Since, the upgraded domain contains a security realm that was created in the release prior to 12.2.1, it does not contain the new policies. Therefore, the validation fails and the partition creation fails.
Workaround
After upgrading the domain, you must perform the following tasks:
For information about creating a new security realm or deleting an existing security realm, see Manage security realms in Administration Console Online Help.
This section describes the following issues and workarounds:
Platform: All
The OpenJPA ClassFileTranformer
does not work when running WebLogic Server on JRockit.
Workaround
Use an alternative method of applying enhancements at build time through an OpenJPA enhancer compiler; do not use the LoadTimeWeaver
.
Platform: All
For the SpringSource petclinic
sample, the petclinic.war
deploys without any problems. The petclinic.ear
will not deploy on WebLogic Server because it is not packaged correctly. A request has been sent to SpringSource to fix the petclinic.ear
packaging.
This section describes the following issues and workarounds:
This section describes the following issue:
Platform: All
The following exception occurs when upgrading Oracle WebLogic Server using the Reconfiguration Wizard with log_priority=ALL
:
Internal Exception: java.sql.SQLIntegrityConstraintViolationException: ORA-00001: unique constraint (NM_OPSS.IDX_JPS_RDN_PDN) violated
Platform: All
The following exception appears in the reconfig.log
after invoking reconfig.sh
with log_priority=ALL
:
[org.xml.sax.SAXParseException; lineNumber: 3; columnNumber: 77; cvc-elt.1: Cannot find the declaration of element 'stringSubsInfo'.]
Several WebLogic Server software features, such as Lifecycle Manager, RESTful Management Services, WLS Administration Console, and Fusion Middleware Control have dependencies on WebLogic Server security features which may not be present in an upgraded domain configuration.
Workaround
You must manually configure the following security features during domain upgrade:
Create an LCMUser
service account if not present. This service account must be present in the administrator group and should have a secure password.
Update the DefaultIdentityAsserter
configuration to include weblogic-jwt-token
as an active type if not present.
This section describes the following issues and workarounds:
Administration Console Fails to Implement session-timeout Changes
Database Connections Become Unstable When a PoolLimitSQLException Occurs
Unable to View the Output of a JSPX Page in Internet Explorer
Unable to View the Output of SVG files in Internet Explorer 7
Spring Dependency Injection Not Supported on JSP Tag Handlers
503 Error When Accessing an Application With a Valid sessionid
Applications Configuring jdbc-connection-timeout-secs Fail to Deploy
No Support for Annotations for JSF-based Web Applications with version lesser than 2.5
After upgrading an application from a WebLogic Server version prior to 12.1.2, a MaxPostSizeExceededException
is reported in the web browser.
Workaround
Set the max-save-post-size
session-descriptor to the maximum size (in bytes) of the POST that will be saved or buffered by the container during FORM authentication.
Platform: All
If the session-timeout
is configured in the web.xml
file, any changes made to change the session-timeout
using the WebLogic Server Administration Console do not take effect.
Workaround
Use a deployment plan to override the session-timeout
setting.
Platform: All
When a PoolLimitSQLException
occurs during a JDBC persistence session, connections to the database become unstable, and may fail with recovery or fail without recovery. This results in the loss of session data. Either an older session or null is returned.
Platform: All
When accessing a Web page using the SSL port, the page fails to open and the following error is reported:
Secure Connection Failed An error occurred during a connection to <hostname>. You have received an invalid certificate. Please contact the server administrator or email correspondent and give them the following information: Your certificate contains the same serial number as another certificate issued by the certificate authority. Please get a new certificate containing a unique serial number.
Workaround
The following workaround can be used for Firefox.
If you have received this error and are trying to access a web page that has a self-signed certificate, perform the following steps in Firefox:
If you are using Internet Explorer or other web browsers, you can ignore the Warning page that appears and continue to the web page.
Platform: MS Windows
When a JSPX page is deployed and is then accessed using some versions of Internet Explorer, the XHTML source is displayed instead of the page contents. This occurs in both normal and osjp.next
modes.
Workaround
The application users should be instructed to use Firefox or Safari to access the application.
Platform: MS Windows
When a page using Scalar Vector Graphics is deployed and is then accessed using Internet Explorer 7 (IE7), the source is displayed instead of the page's graphic contents. This occurs in both normal and osjp.next modes.
Workaround
Application developers should avoid using SVG graphics in their applications, as it is not natively supported in IE7. If used, a warning similar to the following should be added:
All current browsers, with the exception of Internet Explorer, support SVG files. Internet Explorer requires a plug-in to display SVG files. The plug-ins are available for free, for example, the Adobe SVG Viewer at http://www.adobe.com/svg/viewer/install/.
Platform: All
Deployment plans cannot be used to override the following two descriptors during deployment of a Web application or a Web module: WEB-INF/classes/META-INF/persistence.xml and WEB-INF/classes/META-INF/persistence-configuration.xml. Deployment plans can otherwise be used to override any descriptor.
Workaround
Package WEB-INF/classes/META-INF/persistence.xml and WEB-INF/classes/META-INF/persistence-configuration.xml (if present) along with related class files into a JAR file. The JAR file must then be placed in the WEB-INF/lib directory of the Web application or Web module. A deployment plan can be used to override the two descriptors in such a JAR file.
Platform: All
With the Spring extension model enabled, WebLogic Server 10.3 or later does not support Spring Dependency Injection (DI) on JSP tag handlers for performance reasons.
Currently, WebLogic Server supports Spring DI on most Web components, for example, servlets, filters and listeners. Spring DI is not, however, presently supported on JSP tag handlers for performance reasons.
Platform: All
When a session is persistent and an older version of a servlet context is retired, accessing the application with a valid sessionid
will cause a 503 error.
For example, the session-persistent type of a versioned Web application is 'file'. A user can access the application successfully. Later, version 2 of the application is redeployed and version 1 is retired. If the same user accesses the application, they will get a 503 error.
Platform: All
As of WebLogic Server 12.1.2, the jdbc-connection-timeout-secs
element in the weblogic.xml
deployment descriptor has been removed. Applications that configure jdbc-connection-timeout-secs
will fail to deploy on WebLogic Server 12.1.2 server instances, resulting in the following error in the server log:
Unable to load descriptor /.../WEB-INF/weblogic.xml of module myweb. The error is weblogic.descriptor.DescriptorException: VALIDATION PROBLEMS WERE FOUND <6:7> problem: cvc-complex-type.2.4a: Expected elements 'timeout-secs@http://xmlns.oracle.com/weblogic/weblogic-web-app ...' instead of 'jdbc-connection-timeout-secs@http://xmlns.oracle.com/weblogic/weblogic-web-app' here in element session-descriptor@http://xmlns.oracle.com/weblogic/weblogic-web-app
Workaround
Remove the jdbc-connection-timeout-secs
element from the weblogic.xml
deployment descriptor.
Platform: All
The HttpServletRequest
getLocale
and getLocales
methods changed their default behavior for getting the language tag in WebLogic Server. Before 12.1.3, the getLocale
and getLocales
methods return language tags according to RFC3066. Since 12.1.3, these methods return language tags according to RFC5646.
Workaround
If you want to get the language tag according to RFC3066, you need to set the langtag-revision
element of container-descriptor
in the weblogic.xml
file to 3066. For example:
<container-descriptor> <langtag-revision>3066</langtag-revision> </container-descriptor>
The system property -Dweblogic.servlet.langtagRevision
can also determine the locale parsing mechanism. However, if you set a value in langtag-revision
, that value overrides the setting in -Dweblogic.servlet.langtagRevision
. For more information, see langtag-revision in Developing Web Applications, Servlets, and JSPs for Oracle WebLogic Server.
Platform: All
In order to prevent incoming messages that are too large, Tyrus places a constraint on the message frame size. The default value is 4 MB.
Workaround
This value can be configured through the servlet context parameter. For WebLogic Server, this is the weblogic.websocket.tyrus.incoming-buffer-size
parameter and it can be edited as follows:
<context-param> <param-name>weblogic.websocket.tyrus.incoming-buffer-size</param-name> <param-value>value_to_tune</param-value> </context-param>
Platform: All
As of WebLogic Server 12.1.3, the default value of the encoding
element for the jsp-descriptor
element in weblogic.xml
is UTF-8
for JSP pages. Prior to WebLogic Server 12.1.3, the default value for JSP encoding was ISO-8859-1
.
Workaround
To specify ISO-8859-1
as the encoding value for a jsp-descriptor
element, configure the java-charset-name
element in the input-charset
element to ISO-8859-1
. For more information, see weblogic.xml Deployment Descriptor Elements in Developing Web Applications, Servlets, and JSPs for Oracle WebLogic Server.
As of 12.2.1.1, WebLogic Server does not support annotated custom tags for JSF-based Web applications that have the version of the Web Application deployment descriptor, web.xml
, set to 2.5 or older.
Workaround
For compatibility with your Web Application that has version set to 2.5 or older, it is recommended that you upgrade the version of the Web Application deployment descriptor, web.xml
to 3.0.
For instance your existing Web application has the version set to 2.3. You should upgrade it to 3.0 as shown in the following example:
<?xml version = '1.0' encoding = 'windows-1252'?> <web-app xmlns="http://java.sun.com/xml/ns/javaee" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://java.sun.com/xml/ns/javaee http://java.sun.com/xml/ns/javaee/web-app_3_0.xsd" version="3.0"> ... </web-app>
This section describes the following issues and workarounds:
Platform: All
The WLST loadProperties
command does not support loading a property with a name that contains "." characters. For example, if the property myapp.db.default
is present in the property file, WLST throws a name exception:
Problem invoking WLST - Traceback (innermost last): File "<iostream>", line 7, in ? File "<iostream>", line 4, in readCustomProperty NameError: myapp
This is a system limitation of Python and the loadProperties
command. WLST reads the variable names and values and sets them as variables in the Python interpreter. The Python interpreter uses "." as a delimiter to indicate module scoping for the namespace, or package naming, or both. Therefore, the properties file fails because myapp.db.default.version=9i
is expected to be in the myapp.db.default
package. This package does not exist.
Workaround
Use variable names that do not have periods. This will allow you to load the variables from the property file and refer to them in WLST scripts. You could use another character such as "_" or lowercase/uppercase character to delimit the namespace.
As an alternative, you can set variables from a properties files. When you use the variables in your script, during execution, the variables are replaced with the actual values from the properties file. For example:
myapp.py var1=10 var2=20 import myapp print myapp.var1 10 print myapp.var2 20
This will work for one level of namespaces (myapp.var1
, myapp.var2
). It will not work for top level variables that share the same name as the namespace (for example, myapp=oracle
and myapp.var1=10
). Setting the myapp
variable will override the myapp
namespace.
If you need multiple levels, then you can define a package namespace using directories. Create a myapp/db/default directory with a vars.py
file as follows:
var1=10 var2=20
Then import:
import myapp.db.default.vars print myapp.db.default.vars.var1 10
You may need to add __init__.py
files to the subdirectories. Refer to the Python documentation for more information on packages:
Platform: All
The default cachedir
created by Jython 2.2 is not a valid directory. If you are using Jython directly from weblogic.jar
, this causes WLST to error out.
Workaround
There are two workarounds for this issue:
When invoking WLST, specify the -Dpython.cachedir=<
valid_directory
>
parameter, or
Install Jython 2.2.1 separately instead of using the partial Jython that is included in weblogic.jar
.
This section describes the following issue:
Platform: All
Currently, mod_wl
and mod_wl_ohs
only support container level failover and not application level failover. mod_wl_ohs
continues to route requests to a down application as long as the managed server is up and running. In the clustered case, requests continue to go to the container where the original session started even when the application is shutdown, typically resulting in the http error 404.
This section describes the following issues and workarounds:
Sparse Arrays and Partially Transmitted Arrays Are Not Supported
Cannot Use JMS Transport in an Environment That Also Uses a Proxy Server
IllegalArgumentException When Using a Two-Dimensional XML Object in a JWS Callback
FileNotFound Exception When a Web Service Invokes Another Web Service
Client Side Fails to Validate the Signature on the Server Response Message
xmlcatalog Element Entity Cannot Be a Remote File or a File in an Archive
External Catalog File Cannot Be Used in the xmlcatalog Element of clientgen
WS-AT Interoperation Issues With WebSphere and WebLogic Server
No Support for Cloning SAF Agents for Multiple Targets When Using JAX-RPC Extension Template
Platform: All
WebLogic Server does not support Sparse Arrays and Partially Transmitted Arrays as required by the JAX-RPC 1.1 Spec.
Platform: All
The Web Service Description Language (WSDL) compiler does not generate serializable data types, so data cannot be passed to remote EJBs or stored in a JMS destination.
Platform: All
WebLogic Server does not support using a custom exception on a callback that has a package that does not match the target namespace of the parent Web Service.
Workaround
Make sure that any custom exceptions that are used in callbacks are in a package that matches the target namespace of the parent Web service.
Platform: All
You cannot use JMS transport in an environment that also uses a proxy server. This is because, in the case of JMS transport, the Web Service client always uses the t3 protocol to connect to the Web Service, and proxy servers accept only HTTP/HTTPS.
Platform: All
clientgen
fails when processing a WSDL that uses the complex type http://www.w3.org/2001/XMLSchema{schema}
as a Web Service parameter.
Platform: All
Using a two dimensional XmlObject
parameter (XmlObject[][]
) in a JWS callback produces an IllegalArgumentException
.
Workaround
Currently there is no known workaround for this issue.
Platform: All
Using SoapElement[]
as a Web Service parameter with @WildcardBinding(className="javax.xml.soap.SOAPElement[]", binding=WildcardParticle.ANYTYPE)
will always result in an empty array on the client.
Workaround
Do not use the @WildcardBinding
annotation to change the default binding of SOAPElement[]
to WildcardParticle.ANYTYPE
. The SOAPElement[]
default binding is set to WildcardParticle.ANY
.
Platform: All
When Web Service A wants to invoke Web Service B, Web Service A should use the @ServiceClient
annotation to do this. If Web Service B needs a custom policy file that is not attached to the WSDL for Web Service B, then Web Service A will fail to run. Web Service A will look for the policy file at /Web-Inf/classes/policies/
filename
.xml
. Since no policy file exists at that location, WebLogic Server will throw a 'file not found' exception.
Workaround
Attach the custom policy file to Web Service B, as in this example:
@Policy(uri="CustomPolicy.xml", attachToWsdl=true) public class B { ... }
Platform: All
When the security policy has one of these Token Assertions, the client side may fail to validate the signature on the server response message.
<sp:WssX509PkiPathV1Token11/> <sp:WssX509Pkcs7Token11/> <sp:WssX509PkiPathV1Token10/> <sp:WssX509Pkcs7Token10/>
In addition, when there are more than two certifications in the chain for X509 certification for <sp:WssX509Pkcs7Token11/> or <sp:WssX509Pkcs7Token10/> Token Assertion, the server side may fail to validate the signature on the incoming message.
A policy such as the following policy is not supported, unless the entire certificate chain remains on the client side.
<sp:AsymmetricBinding> <wsp:Policy> <sp:InitiatorToken> <wsp:Policy> <sp:X509Token sp:IncludeToken='. . ./IncludeToken/AlwaysToRecipient'> <wsp:Policy> <sp:WssX509Pkcs7Token11/> </wsp:Policy> </sp:X509Token> </wsp:Policy> </sp:InitiatorToken> <sp:RecipientToken> <wsp:Policy> <sp:X509Token sp:IncludeToken='. . ./IncludeToken/Never'> <wsp:Policy> <sp:WssX509Pkcs7Token11/> </wsp:Policy> </sp:X509Token> </wsp:Policy> </sp:RecipientToken> . . . </wsp:Policy> </sp:AsymmetricBinding>
Workaround
Use either of the following two solutions:
When there are multiple certifications in the X509 Certificate chain, WssX509PkiPathV1Token11/>
or <sp:WssX509PkiPathV1Token10/>
should be used, instead of <sp:WssX509Pkcs7Token11/>
or <sp:WssX509Pkcs7Token10/>
.
Platform: All
For the xmlcatalog
element in build.xml
, the location of an entity must be a file on the local file system. It cannot be a remote file (for example, http:
) or a file in an archive (for example, jar:
).
Workaround
If necessary, define the remote element as an entity in a catalog file instead.
Platform: All
The public
element in a catalog file is not supported when using the XML Catalogs feature. It is not supported to be consistent with JAX-WS EntityResolver implementation. WebLogic Server only supports defining the system
element in a catalog file.
Platform: All
The local xmlcatalog
element does not work well due to an Ant limitation.
Workaround
In the ant build.xml
file, you have to define a local element above a clientgen(wsdlc)
task when you are in the same target, or define the element out of any targets.
Platform: All
An external catalog file cannot be used in the xmlcatalog
element of a clientgen
task. For example, this snippet of an ant build file will not work:
<clientgen ... <xmlcatalog> <catalogpath> <pathelement location='wsdlcatalog.xml'/> </catalogpath> </xmlcatalog>
This is a limitation of the Ant XML Catalog.
Workaround
Resource locations can be specified either in-line or in an external catalog file(s), or both. In order to use an external catalog file, the xml-commons
resolver library (resolver.jar
) must be in your classpath. External catalog files may be either plain text format or XML format. If the xml-commons
resolver library is not found in the classpath, external catalog files, specified in <catalogpath>
paths, will be ignored and a warning will be logged. In this case, however, processing of inline entries will proceed normally.
Currently, only <dtd>
and <entity>
elements may be specified inline. These correspond to the OASIS catalog entry types PUBLIC and URI respectively.
Platform: All
Web Services Atomic Transactions (WS-AT) 1.1 interoperation using WebSphere as the client and either WebLogic Server or JRF as the service does not work.
WS-AT 1.1 interoperation does work when WebSphere is the service and either WebLogic Server or JRF is the client. In this case, interoperation works only if you have WebSphere 7 with Fix/Feature Pack 7.
When shutting down a WebLogic Server instance that has a JAX-RS application running on it, you may observe the following error message in the server log:
<Error> <org.glassfish.jersey.server.internal.monitoring.MonitoringStatisticsProcessor > <BEA-000000> <Exception thrown when provider class org.glassfish.jersey.server.internal.monitoring.MonitoringFeature$StatisticsLi stener was processing MonitoringStatistics. Removing provider from further processing. ...
This error message is benign and can be ignored.
Platform: All
When you extend your domain that has multiple targets using the JAX-RPC extension template, the CIE processing does not support SAF agent to be cloned for multiple targets. Each instance of SAF agent is targeted to a single target.
Workaround
You must use WLST to create additional SAF agents for multiple targets. However, each instance of SAF agent can be targeted to only one target. The following example creates SAF agents for the domain, domain1, containing two target clusters.
readDomain('domain1') cd('/') create('ReliableWseeSAFAgent1','SAFAgent') create('ReliableWseeSAFAgent2','SAFAgent') assign('SAFAgent','ReliableWseeSAFAgent1','Target','SenderCluster') assign('SAFAgent','ReliableWseeSAFAgent2','Target','ReceiverCluster') wlsuOfflineUpdateWLSDomain()
This section describes the following issue and workaround:
Platform: All
View classes are not set on a per connection basis.
A shared WebLogic Tuxedo Connector hash table can cause unexpected behavior in the server if two applications point to the same VIEW name with different definitions. There should be a hash table for the view classes on the connection as well as for the Resource section.
Workaround
Ensure that all VIEW classes defined across all your WebLogic Workshop applications are consistent, meaning that you have the same VIEW name representing the same VIEW class.
This section describes documentation errata:
Platform: All
The Search function in the Samples viewer does not work when accessing the Examples documentation by selecting Oracle WebLogic > WebLogic Server > Examples > Documentation from the Windows Start menu.
Workaround
To search the Sample Applications and Code Examples, you must start the Examples server and navigate to http://localhost:7001/examplesWebApp/docs/core/index.html
. Click Instructions and then Search.
Platform: All
The samples viewer Search function may sometimes return topics that display the Japanese and English versions of some Avitek Medical Records topics simultaneously.
Platform: All
After extracting the WebLogic Server documentation library ZIP files that are available from http://www.oracle.com/technetwork/middleware/weblogic/documentation/index.html
, the HTML pages may not display properly in some cases for the following libraries:
E12840_01 (WebLogic Server 10.3.0 documentation library)
E12839_01 (WebLogic Server 10.3.1 documentation library)
E14571_01 (WebLogic Server 10.3.3 documentation library)
Workarounds
For library E12840-01, after extracting the E12840_01.zip library file, if the HTML pages are not formatting correctly, perform the following steps:
/global_resources
directory in the directory structure./global_resources
directory to the root directory of the same drive.For libraries E12839-01 and E14571-01, this issue occurs only on Windows operating systems. If the HTML pages of the extracted library are not formatting correctly, try extracting the ZIP file using another extraction option in your unzip utility. For example, if you are using 7-Zip to extract the files, select the Full pathnames option. Note that you cannot use the Windows decompression utility to extract the library ZIP file.
Platform: All
In previous versions of WebLogic Server, when a remote client (a call from outside the container) used IIOP and the wlclient.jar
file to call an EJB, and that EJB returned a value object that caused a class version mismatch between the client and the EJB, the following error occurred:
org.omg.CORBA.BAD_PARAM: Could not find FVD class
This issue also occurred between WebLogic Server instances.
This issue is fixed in WebLogic Server 12.2.1.1
Issue
Impacted Platforms: All
The documentation for previous patch set releases of Oracle WebLogic Server 12.2.1 stated the incorrect version of JavaMail supported, the correct version is 1.5.
The documentation for previous patch set releases of Oracle WebLogic Server 12.2.1 stated the incorrect version of Java EE Interceptors supported, the correct version is 1.2.
Note:
This change applies to all releases from 12.2.1.0 onwards.Workaround
N/A