Configuration
|
Yes__No__
|
Have you determined the hardware configuration for each server?
|
|
Yes__No__
|
Have you determined the type and number of cabinets and racks you need?
|
|
Yes__No__
|
Have you determined how you will populate each rack?
|
|
Yes__No__
|
Have you determined which external peripherals, such as terminals, monitors, keyboards, SCSI devices, and so forth, the servers require?
|
Environmental
|
Yes__No__
|
Does the data center environment meet the server specifications for temperature and humidity?
|
|
Yes__No__
|
Have you determined the thermal load, heat dissipation, and air conditioning requirements of all equipment in the data center?
|
|
Yes__No__
|
Can you maintain the data center environment when certain failures occur, such as power failure, air conditioning unit failure, or humidity control unit failure?
|
|
Yes__No__
|
Is fire suppression and alarm equipment installed?
|
Power
|
Yes__No__
|
Have you determined the maximum power requirements of the servers?
|
|
Yes__No__
|
Have you considered using an alternate source of power for grid independence and backup power for the local sub-station?
|
|
Yes__No__
|
Have you installed a UPS?
|
|
Yes__No__
|
Do you have sufficient power receptacles and circuit breakers for each server and its peripherals?
|
|
Yes__No__
|
Are the power receptacles within 15 feet (4.6 m) of the racks or within 6 feet (1.8 m) of a standalone server?
|
|
Yes__No__
|
Have you installed and labeled the circuit breakers?
|
Physical
|
Yes__No__
|
Does the facility's loading dock meet standard common carrier truck requirements? If not, have you made other arrangements for unloading the racks and servers, such as providing a fork lift?
|
|
Yes__No__
|
Are pallet jacks or carts available to move the servers and racks from the loading dock to the computer room?
|
|
Yes__No__
|
Will the equipment fit through the access route and into the computer room?
|
|
Yes__No__
|
Have you calculated the weight of each rack with all the equipment installed within it?
|
|
Yes__No__
|
Is the data center floor able to support the weight of the servers and racks?
|
|
Yes__No__
|
Have you established where you will locate each rack on the data center floor?
|
|
Yes__No__
|
Are the servers and racks positioned so that the heated exhaust air of one server does not enter the air inlet of another server?
|
|
Yes__No__
|
Is there sufficient room around the racks for server access and maintenance?
|
Miscellaneous
|
Yes__No__
|
Are there sufficient number of people available to unload, unpack, and install the servers into the racks?
|
|
Yes__No__
|
Have system administrators and service technicians enrolled in appropriate training courses to upgrade their skills, as necessary?
|
|
Yes__No__
|
Have you acquired all the hardware needed to set up the servers and racks?
|
|
Yes__No__
|
Do you have the documents required to install the servers into the racks?
|