C H A P T E R  4

Understanding the J4000 Family Event Log

TABLE 4-1 provides event IDs, log listings, descriptions, and where applicable, Service action recommendations.

Refer to the Sun StorageTek Common Array Manager User Guide for the J4000 Array Family (820-3765-nn) for information on viewing system events and configuring automatic notifications.

 
TABLE 4-1 J4000 Family Event Log Listings

Event ID

System Event Name

Description

Service Action

1

SYSLOG_SYSTEM_POWER_ON

System was powered on and booted.

 

2

SYSLOG_SYSTEM_POWER_OFF

System was shut down.

Not currently supported.

3

SYSLOG_STATUS_FAIL_SIM0

SIM 0 was disabled due to runtime failure.

Contact Sun Service:

http://www.sun.com/support/contacting

4

SYSLOG_STATUS_FAIL_SIM1

SIM 1 was disabled due to runtime failure.

Contact Sun Service:

http://www.sun.com/support/contacting

5

SYSLOG_PLUGOUT_FAN0

Fan 0 was removed.

J4200 only. System is in degraded mode. Reinstall Fan 0 in 15 minutes to ensure system health.

6

SYSLOG_PLUGOUT_FAN1

Fan1 was removed.

J4200 only. System is in degraded mode. Reinstall Fan 1 in 15 minutes to ensure system health.

7

SYSLOG_PLUGOUT_SPS0

Power Supply 0 was removed.

J4200 only. System is in a degraded mode. Reinstall Power Supply 0 to ensure a high degree of fault tolerance.

8

SYSLOG_PLUGOUT_SPS1

Power Supply 1 was removed.

System is in a degraded mode. Reinstall Power Supply 1 to ensure a high degree of fault tolerance.

9

SYSLOG_PLUGOUT_DISK

Disk 1 was removed.

 

10

SYSLOG_PLUGOUT_PORT

SAS port 1 is down.

Check the connection to SAS port 1.

11

SYSLOG_PLUGIN_OK_SIM0

SIM 0 is enabled.

 

12

SYSLOG_PLUGIN_OK_SIM1

SIM 1 is enabled.

 

13

SYSLOG_PLUGIN_FAN0

Fan 0 is present.

 

14

SYSLOG_PLUGIN_FAN1

Fan 1 is present.

 

15

SYSLOG_PLUGIN_SPS0

Power 0 is present.

 

16

SYSLOG_PLUGIN_SPS1

Power 1 is present.

 

17

SYSLOG_POWER_BTN

Front panel button is pressed to mute alarm.

 

18

SYSLOG_PHY_ERR_CNT

PHY error count exceeds threshold value.

The drive slot or SAS port is unstable. Check disk status and SAS cable connections.

19

SYSLOG_PWROK_SPS0

Power supply 0 has power.

 

20

SYSLOG_PWROK_SPS1

Power supply 1 has power.

 

21

SYSLOG_NOT_PWROK_SPS0

Power supply 0 has failed.

Check the connection between the power cord and Power Supply 0.

22

SYSLOG_NOT_PWROK_SPS1

Power supply 1 has failed.

Check the connection between the power cord and Power Supply 1.

23

SYSLOG_ACOK_SPS0

Power supply 0 is OK.

J4400 only.

24

SYSLOG_ACOK_SPS1

Power Supply 1 is OK.

J4400 only.

25

SYSLOG_NOT_ACOK_SPS0

Power Supply 0 is down.

J4400 only. Check the connection between the power cord and Power Supply 0.

26

SYSLOG_NOT_ACOK_SPS1

Power Supply 1 is down.

J4400 only. Check the connection between the power cord and Power Supply 1.

27

SYSLOG_FAIL_SPS0

Power Supply 0 was removed.

J4400 only. System is in degraded mode. Reinstall Power Supply 0 to ensure a high degree of fault tolerance.

28

SYSLOG_FAIL_SPS1

Power Supply 1 was removed.

J4400 only. System is in degraded mode. Reinstall Power Supply 1 to ensure a high degree of fault tolerance.

29

SYSLOG_OK_SPS0

Power Supply 0 was installed.

J4400 only.

30

SYSLOG_OK_SPS1

Power Supply 1 was installed.

J4400 only.

31

SYSLOG_PLUGIN_PORT

SAS port 1 is up.

 

32

SYSLOG_WDT_TIMEOUT

SIM 1 is disabled due to timeout.

 

33

SYSLOG_DIAG_PASS

Completed and passed diagnostic test.

 

34

SYSLOG_DIAG_FAIL

Completed and failed diagnostic test.

Contact Sun Service:

http://www.sun.com/support/contacting

35

SYSLOG_PLUGOUT_SIM

SIM 1 was removed.

 

36

SYSLOG_PLUGIN_SIM

SIM 1 is installed.

 

37

SYSLOG_FAIL_I2C

Controller 1 has encountered a failure.

A hardware error occurred in SIM 1. Please replace SIM 1 with a new one immediately.

38

SYSLOG_SYSTEM_HEALTHY

System is back to normal state.

 

39

SYSLOG_PLUGIN_DISK

Disk 1 is installed

 

40

SYSLOG_FW_DIFF

The two SIM firmware versions are incompatible.

 

41

SYS

Fan 1 has failed.

 

42

SYSLOG_TEMP_WARN

Nominal temperature has been exceeded.

 

43

SYSLOG_TEMP_CRIT

Maximum temperature has been exceeded.

 

44

SYSLOG_VOLT_WARN

Nominal voltage has been exceeded.

 

45

SYSLOG_VOLT_CRIT

Maximum voltage has been exceeded.