To help you identify configuration problems, Nucleus displays messages about the configuration process. You configure the level of logging messages for Nucleus through the configuration file Nucleus.properties
. By default, Nucleus is configured to display warning and error messages; however, it can be configured to display informative and debugging messages also For example, the default configuration looks like this:
initialServiceName=/Initial loggingError=true loggingWarning=true loggingInfo=false loggingDebug=false
If you have problems with configuration, it can be helpful to set the loggingInfo
and loggingDebug
properties to true
and examine the messages for indications where the problems might be.
You can change Nucleus.properties
settings at runtime through the ATG Control Center Components window, by changing the property values of the /
component.
Note: These settings apply only to Nucleus, and do not affect the logging settings of other components.
For more information about using the logging system in the ATG platform, see the Dynamo Logging section of the Logging and Data Collection chapter.