Supported
Servers and Operating Systems
This section describes servers that support the Sun Flash
Accelerator F40 PCIe Card. For detailed information about using
this card with your server, see the product notes for your server,
available at:
https://docs.oracle.com
The following servers are supported for the Sun Flash Accelerator
F40 PCIe Card:
|
|
|
|
SPARC T4-1
|
1 to 2
|
5, 3
|
|
SPARC T4-2
|
1 to 4
|
9, 8, 7, 0 (Slot 6 if Slot 0 is unavailable)
|
|
SPARC T5-2
|
1 to 4
|
1, 8 ,2, 7, 3, 6, 4, 5
|
|
SPARC T5-4
|
1 to 8
|
1, 3, 5, 7, 9, 11, 13, 15
|
|
SPARC T5-8
|
1 to 8
|
1, 3, 5, 7, 9, 11, 13, 15
|
|
SPARC M5-32
|
1 to 60
|
Slot 8 in each I/O unit (IOU) is not supported.
|
|
Fujitsu M10-1
|
1 to 3
|
2, 0, 1
|
|
Fujitsu M10-4
|
1 to 11
|
10, 6, 2, 8, 4, 9, 5, 1, 7, 3, 0
|
|
Fujitsu M10-4S
|
1 to 8
|
6, 2, 4, 5, 1, 7, 3, 0
|
|
|
Note - Direct I/O support (DIO) is available for SPARC T4-1
and T4-2 servers.
|
|
|
|
Sun Server X3-2L
|
1 to 4
|
1, 2, 4, 5
|
-
Oracle Solaris 11.1
-
Oracle Solaris 10 8/11
-
Oracle Linux 5.8, based on UEK2 (Unbreakable Linux
Kernel Release 2)
-
Oracle Linux 6.2, 6.3, based on UEK2 (Unbreakable
Linux Kernel Release 2)
|
|
Other servers and processors may be added to this list in
the future, if they qualify. Check your server product notes for
confirmation that your server has subsequently been qualified.
| Caution - Any unsupported configuration
causes the host to power off as soon as it is powered on. A fault
is generated on the service processor when an unsupported configuration
is detected. The fault clears after the unsupported configuration
is fixed and the host is powered on. |
Note - For up-to-date information on supported servers, operating
systems and required patchsets, refer to the product notes for the
servers.