Sun Blade X4-2B Server Module Fails When Launching Remote Console (18962552)
Dual 16 Gigabit/Sec Fibre Channel / 10Gbps FCoE Host Adapter, Emulex
BIOS MPS Setting Added (18364710 and 18317148 and 15752501)
Do Not Use Operating System Tools or Utilities to Manage UEFI Boot Variables (15818528)
One DIMM in a Channel Has an Uncorrectable Error, Other DIMMs Might Have Errors (16181966)
Hot-plugging 2 PCIe EMs Can Cause Correctable Error Messages (15752501)
Do Not Reboot the SP and Host Simultaneously (16346073 and 17013976)
Oracle ILOM restore_status Parameter Shows Partial Status (7167938)
Oracle Recommendations for Drive Slot Population and Virtual Drive Creation (7124194)
PXE-booting Fails When Using Cisco Switch (7149683)
When Running an Emulex HBA in UEFI BIOS Boot Mode, the
Oracle System Assistant Issues
If a Dual 8Gb Fibre Channel and Dual 1 GbE (QLogic) or Sun InfiniBand QDR Host Channel Adapter PCIe ExpressModule is installed in the chassis PCI EM slot 0 and the blade is reset, a fault might be logged in the SP. For example:
fault.cpu.intel.l2cache on /SYS/MB/P0
The system will auto reboot several times until the PCIe card recovers, then the system reboots normally.
Workaround
Update to SW 1.0.1 or later. This issue is corrected in CPLD 3.3, SW 1.0.1. See Getting Server Firmware and Software Updates.