4.2 Exalogic Machine Half Rack

Table 4-2 lists the default ILOM, NET0, and InfiniBand Bonded IP addresses assigned during manufacturing to Exalogic compute nodes and other hardware components in an Exalogic machine half rack.

Table 4-2 Default ILOM, NET0, and IB Bonded IP for Exalogic Half Rack

Unit Rack Component (Front View) ILOM IP Address NET0 IP Address IB Bonded IP Address

42

4U Solid Filler

Not applicable

Not applicable

Not applicable

41

Not applicable

Not applicable

Not applicable

40

Not applicable

Not applicable

Not applicable

39

Not applicable

Not applicable

Not applicable

38

4U Solid Filler

Not applicable

Not applicable

Not applicable

37

Not applicable

Not applicable

Not applicable

36

Not applicable

Not applicable

Not applicable

35

Not applicable

Not applicable

Not applicable

34

4U Solid Filler

Not applicable

Not applicable

Not applicable

33

Not applicable

Not applicable

Not applicable

32

Not applicable

Not applicable

Not applicable

31

Not applicable

Not applicable

Not applicable

30

2U Solid Filler

Not applicable

Not applicable

Not applicable

29

Not applicable

Not applicable

Not applicable

28

Compute Node

192.168.1.118

192.168.1.18

192.168.10.18

27

Compute Node

192.168.1.117

192.168.1.17

192.168.10.17

26

1U Solid Filler

Not applicable

Not applicable

Not applicable

25

Cisco Management Switch

Not applicable

192.168.1.200

Not applicable

24

1U Solid Filler

Not applicable

Not applicable

Not applicable

23

Sun Network QDR InfiniBand Gateway Switch

192.168.1.202

Not applicable

Not applicable

22

Server head for the storage appliance

192.168.1.116

192.168.1.16

192.168.10.16

21

Server head for the storage appliance

192.168.1.115

192.168.1.15

192.168.10.15

20

Disk storage tray for the storage appliance

Not applicable

Not applicable

Not applicable

19

18

17

16

Sun Network QDR InfiniBand Gateway Switch

192.168.1.201

Not applicable

Not applicable

15

Compute Node

192.168.1.114

192.168.1.14

192.168.10.14

14

Compute Node

192.168.1.113

192.168.1.13

192.168.10.13

13

Compute Node

192.168.1.112

192.168.1.12

192.168.10.12

12

Compute Node

192.168.1.111

192.168.1.11

192.168.10.11

11

Compute Node

192.168.1.110

192.168.1.10

192.168.10.10

10

Compute Node

192.168.1.109

192.168.1.9

192.168.10.9

9

Compute Node

192.168.1.108

192.168.1.8

192.168.10.8

8

Compute Node

192.168.1.107

192.168.1.7

192.168.10.7

7

Compute Node

192.168.1.106

192.168.1.6

192.168.10.6

6

Compute Node

192.168.1.105

192.168.1.5

192.168.10.5

5

Compute Node

192.168.1.104

192.168.1.4

192.168.10.4

4

Compute Node

192.168.1.103

192.168.1.3

192.168.10.3

3

Compute Node

192.168.1.102

192.168.1.2

192.168.10.2

2

Compute Node

192.168.1.101

192.168.1.1

192.168.10.1

1

Sun Datacenter InfiniBand Switch 36

192.168.1.205

Not applicable

Not applicable

-

-

PDU-A (left from rear view)

192.168.1.210

Not applicable

Not applicable

PDU-B (right from rear view)

192.168.1.211

Not applicable

Not applicable

Note:

The following table shows the hardware that is included in different Exalogic versions.

Exalogic Rack Compute Node’s Server Cisco Management Switch Storage Appliance
X6–2 Oracle Server X6-2 Cisco 4948E Oracle ZS5-ES
X5–2 Oracle Server X5-2 Cisco 4948E Oracle ZS3-ES
X4–2 Sun Server X4-2 Cisco 4948E-F-S Oracle ZS3-ES
X3–2 Sun Server X3-2 Cisco 4948E-F-S Sun ZFS 7320
X2–2 Sun Fire X4170 M2 Cisco 4948 Sun ZFS 7320