Sun Logo


ILOM Supplement for Sun Blade 6220 Modular Server

820-0047-10



Contents

ILOM Supplement for Sun Blade X6220 Server Module

Documentation and Updates

Hardware Installation Documentation

Related Documentation

Using UNIX Commands

Third-Party Web Sites

Hardware Information

Server Locator Indicator

Connecting to ILOM

Option 1 - Connecting to ILOM Through the Chassis Ethernet Port

Option 2 - Connecting to ILOM Through the Chassis Serial Connector

Option 3 - Connecting to ILOM Through a Dongle Cable

Resetting the Service Processor and BIOS Passwords

Temperature, Voltage, and Fan Sensors

Sensor List

Sensor Details

sys.power

sys.locate

sys.locate.btn

sys.alert

sys.ok2rm

sys.slotid

cmm.prsnt Sensor

nem[0..1].prsnt

Motherboard Temperature Sensors

mb.t_amb[0..2]

Mainboard Voltage Sensors

mb.v_bat

mb.v_+3v3aux

mb.v_+3v3

mb.v_+5v

mb.v_+12v

mb.v_+2v5

mb.v_+1v5

mb.v_+1v2

Power Supply Sensors

ps[0..1].prsnt

ps[0..1].vinok[0..1]

ps[0..1].pwrok[0..1]

HDD Sensors

hdd[0..3].prsnt

hdd[0..3].fail

hdd[0..3].state

Fan Sensors

fm[0..5].f[0..1].speed

fm[0..5].fail

CPU [0..1] and DIMM Sensors

p[0..1].prsnt

p[0..1].fail

p[0..1].d[0..7].fail

CPU [0..1] Fan Control Temperature Sensors

p[0..1].t_core

CPU [0..1] Voltage Sensors

p[0..1].v_core

p[0..1].v_vtt

p[0..1].v_vddio

Server Module Present

bl[0..9].prsnt