This section provides the procedures for maintaining a StorEdge D1000 disk array. The following table list these procedures.
Table 5-2 Task Map: Maintaining a StorEdge D1000 Disk Array
Task |
For Instructions, Go To... |
---|---|
Add a disk drive Use the cfgadm(1M), devfsadm(1M), scgdevs(1M), and scdidadm(1M) commands to add a disk drive to a disk array. | |
Replace a disk drive | |
Remove a disk drive | |
Add a disk array to an existing cluster Use the nvedit(1M), shutdown(1M), scswitch(1M), and scdidadm commands to add a disk array to an existing cluster. | |
Replace a disk array in an existing cluster Use this procedure to replace a disk array with a new disk array. This procedure assumes that you want to retain the disk drives in the disk array you want to replace. | |
Remove a disk array from an existing cluster Use the cfgadm, devfsadm, and scdidadm commands to remove a disk array without replacing it with another disk array. |
Use this procedure to add a disk drive to an existing cluster. Perform the steps in this procedure in conjunction with the procedures in Sun Cluster 3.0 System Administration Guide and your server hardware manual.
For conceptual information on quorum, quorum devices, global devices, and device IDs, see Sun Cluster 3.0 Concepts.
Locate an empty disk slot in the disk array for the disk drive you want to add.
Identify the disk slot in the disk array for the disk drive being added, and note the target number. Refer to the documentation that shipped with your StorEdge D1000 disk array.
Install the disk drive.
For more information, see the documentation that shipped with the disk array.
On all nodes attached to the disk array, configure the disk drive.
# cfgadm -c configure cN # devfsadm |
On all nodes, ensure that entries for the disk drive have been added to the /dev/rdsk directory.
# ls -l /dev/rdsk |
If needed, use the format(1M) command or the fmthard(1M) command to partition the disk drive.
From any node, update the global device namespace.
If a volume management daemon such as vold is running on your node, and you have a CD-ROM drive connected to the node, a device busy error might be returned even if no disk is in the drive. This error is an expected behavior.
# scgdevs |
On all nodes, verify that a device ID (DID) has been assigned to the disk drive.
# scdidadm -l |
As shown in "Example--Adding a StorEdge D1000 Disk Drive", the DID 35 assigned to the new disk drive might not be in sequential order in the disk array.
Perform volume management administration to add the new disk drive to the configuration.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
If you want this new disk drive to be a quorum device, add the quorum device.
Refer to Sun Cluster 3.0 System Administration Guide for the procedure on adding a quorum device.
The following example shows how to apply the procedure for adding a StorEdge D1000 disk array disk drive.
# scdidadm -l 16 phys-circinus-3:/dev/rdsk/c2t0d0 /dev/did/rdsk/d16 17 phys-circinus-3:/dev/rdsk/c2t1d0 /dev/did/rdsk/d17 18 phys-circinus-3:/dev/rdsk/c2t2d0 /dev/did/rdsk/d18 19 phys-circinus-3:/dev/rdsk/c2t3d0 /dev/did/rdsk/d19 ... 26 phys-circinus-3:/dev/rdsk/c2t12d0 /dev/did/rdsk/d26 30 phys-circinus-3:/dev/rdsk/c1t2d0 /dev/did/rdsk/d30 31 phys-circinus-3:/dev/rdsk/c1t3d0 /dev/did/rdsk/d31 32 phys-circinus-3:/dev/rdsk/c1t10d0 /dev/did/rdsk/d32 33 phys-circinus-3:/dev/rdsk/c0t0d0 /dev/did/rdsk/d33 34 phys-circinus-3:/dev/rdsk/c0t6d0 /dev/did/rdsk/d34 8190 phys-circinus-3:/dev/rmt/0 /dev/did/rmt/2 # cfgadm -c configure c1 # devfsadm # scgdevs Configuring DID devices Could not open /dev/rdsk/c0t6d0s2 to verify device id. Device busy Configuring the /dev/global directory (global devices) obtaining access to all attached disks reservation program successfully exiting # scdidadm -l 16 phys-circinus-3:/dev/rdsk/c2t0d0 /dev/did/rdsk/d16 17 phys-circinus-3:/dev/rdsk/c2t1d0 /dev/did/rdsk/d17 18 phys-circinus-3:/dev/rdsk/c2t2d0 /dev/did/rdsk/d18 19 phys-circinus-3:/dev/rdsk/c2t3d0 /dev/did/rdsk/d19 ... 26 phys-circinus-3:/dev/rdsk/c2t12d0 /dev/did/rdsk/d26 30 phys-circinus-3:/dev/rdsk/c1t2d0 /dev/did/rdsk/d30 31 phys-circinus-3:/dev/rdsk/c1t3d0 /dev/did/rdsk/d31 32 phys-circinus-3:/dev/rdsk/c1t10d0 /dev/did/rdsk/d32 33 phys-circinus-3:/dev/rdsk/c0t0d0 /dev/did/rdsk/d33 34 phys-circinus-3:/dev/rdsk/c0t6d0 /dev/did/rdsk/d34 35 phys-circinus-3:/dev/rdsk/c2t13d0 /dev/did/rdsk/d35 8190 phys-circinus-3:/dev/rmt/0 /dev/did/rmt/2 # |
Use this procedure to replace a StorEdge D1000 disk array disk drive. "Example--Replacing a StorEdge D1000 Disk Drive" shows you how to apply this procedure. Perform the steps in this procedure in conjunction with the procedures in Sun Cluster 3.0 System Administration Guide and your server hardware manual. Use the procedures in your server hardware manual to identify a failed disk drive.
For conceptual information on quorum, quorum devices, global devices, and device IDs, see Sun Cluster 3.0 Concepts.
Identify the disk drive that needs replacement.
If the disk error message reports the drive problem by device ID (DID), use the scdidadm -l command to determine the Solaris logical device name. If the disk error message reports the drive problem by the Solaris physical device name, use your Solaris documentation to map the Solaris physical device name to the Solaris logical device name. Use this Solaris logical device name and DID throughout this procedure.
# scdidadm -l deviceID |
Determine if the disk drive you want to replace is a quorum device.
# scstat -q |
If the disk drive you want to replace is a quorum device, remove the quorum device before you proceed. Otherwise, proceed to Step 3.
Refer to Sun Cluster 3.0 System Administration Guide for procedures on replacing a quorum device and putting a quorum device into maintenance state.
If possible, back up the metadevice or volume.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
Perform volume management administration to remove the disk drive from the configuration.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
Identify the failed disk drive's physical DID.
Use this physical DID in Step 12 to verify that the failed disk drive has been replaced with a new disk drive.
# scdidadm -o diskid -l cNtXdY |
If you are using Solstice DiskSuite as your volume manager, save the disk partitioning for use when partitioning the new disk drive.
If you are using VERITAS Volume Manager, proceed to Step 7.
# prtvtoc /dev/rdsk/cNtXdYsZ > filename |
Do not save this file under /tmp because you will lose this file when you reboot. Instead, save this file under /usr/tmp.
Replace the failed disk drive.
For more information, see the documentation that shipped with your disk array.
On one node attached to the disk array, run the devfsadm(1M) command to probe all devices and to write the new disk drive to the /dev/rdsk directory.
Depending on the number of devices connected to the node, the devfsadm command can take at least five minutes to complete.
# devfsadm |
If you are using Solstice DiskSuite as your volume manager, from any node connected to the disk array, partition the new disk drive, using the partitioning you saved in Step 6.
If you are using VERITAS Volume Manager, proceed to Step 10.
# fmthard -s filename /dev/rdsk/cNtXdYsZ |
One at a time, shut down and reboot the nodes connected to the disk array.
# scswitch -S -h nodename # shutdown -y -g 0 -i 6 |
For more information on shutdown, see Sun Cluster 3.0 System Administration Guide.
From any node connected to the disk drive, update the DID database.
# scdidadm -R deviceID |
From any node, confirm that the failed disk drive has been replaced by comparing the new physical DID to the physical DID in Step 5.
If the new physical DID is different from the physical DID in Step 5, you successfully replaced the failed disk drive with a new disk drive.
# scdidadm -o diskid -l cNtXdY |
On all nodes, upload the new information to the DID driver.
If a volume management daemon such as vold is running on your node, and you have a CD-ROM drive connected to the node, a device busy error might be returned even if no disk is in the drive. This error is an expected behavior.
# scdidadm -ui |
Perform volume management administration to add the disk drive back to its diskset or disk group.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
If you want this new disk drive to be a quorum device, add the quorum device.
Refer to Sun Cluster 3.0 System Administration Guide for the procedure on adding a quorum device.
The following example shows how to apply the procedure for replacing a StorEdge D1000 disk array disk drive.
# scdidadm -l d20 20 phys-schost-2:/dev/rdsk/c3t2d0 /dev/did/rdsk/d20 # scdidadm -o diskid -l c3t2d0 5345414741544520393735314336343734310000 # prtvtoc /dev/rdsk/c3t2d0s2 > /usr/tmp/c3t2d0.vtoc ... # devfsadm # fmthard -s /usr/tmp/c3t2d0.vtoc /dev/rdsk/c3t2d0s2 # scswitch -S -h node1 # shutdown -y -g 0 -i 6 ... # scdidadm -R d20 # scdidadm -o diskid -l c3t2d0 5345414741544520393735314336363037370000 # scdidadm -ui |
Use this procedure to remove a disk drive from a StorEdge D1000 disk array. Perform the steps in this procedure in conjunction with the procedures in Sun Cluster 3.0 System Administration Guide and your server hardware manual.
For conceptual information on quorum, quorum devices, global devices, and device IDs, see Sun Cluster 3.0 Concepts.
Determine if the disk drive you want to remove is a quorum device.
# scstat -q |
If the disk drive you want to remove is a quorum device, remove the quorum device before you proceed. Otherwise, proceed to Step 2.
Refer to Sun Cluster 3.0 System Administration Guide for procedures on removing a quorum device and putting a quorum device into maintenance state.
If possible, back up the metadevice or volume.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
Perform volume management administration to remove the disk drive from the configuration.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
Identify the disk drive that needs to be removed and the slot that the disk drive needs to be removed from.
If the disk error message reports the drive problem by DID, use the scdidadm -l command to determine the Solaris device name.
# scdidadm -l deviceID # cfgadm -al |
Remove the disk drive.
For more information, see the documentation that shipped with the disk array.
On all nodes, remove references to the disk drive.
# cfgadm -c unconfigure cN::dsk/cNtXdY # devfsadm -C # scdidadm -C |
Use this procedure to install a disk array in an existing cluster. Perform the steps in this procedure in conjunction with the procedures in Sun Cluster 3.0 System Administration Guide and your server hardware manual.
For conceptual information on multi-initiator SCSI and device IDs, see Sun Cluster 3.0 Concepts.
Ensure that each device in the SCSI chain has a unique SCSI address.
The default SCSI address for host adapters is 7. Reserve SCSI address 7 for one host adapter in the SCSI chain. This procedure refers to the host adapter you choose for SCSI address 7 as the host adapter on the second node. To avoid conflicts, in Step 7 you will change the scsi-initiator-id of the remaining host adapter in the SCSI chain to an available SCSI address. This procedure refers to the host adapter with an available SCSI address as the host adapter on the first node. SCSI address 6 is usually available.
For more information, see the OpenBoot 3.x Command Reference Manual and the labels inside the storage device.
Even though a slot in the disk array might not be in use, you should avoid setting the scsi-initiator-id for the first node to the SCSI address for that disk slot. This precaution minimizes future complications if you install additional disk drives.
Shut down and power off the first node.
# scswitch -S -h nodename # shutdown -y -g 0 |
For more information on shutdown, see Sun Cluster 3.0 System Administration Guide.
Install the host adapters in the node.
For the procedure on installing host adapters, see the documentation that shipped with your host adapters and nodes.
Connect the differential SCSI cable between the node and the disk array as shown in Figure 5-2.
Make sure that the entire SCSI bus length to each enclosure is less than 25 m. This measurement includes the cables to both nodes, as well as the bus length internal to each enclosure, node, and host adapter. Refer to the documentation that shipped with the enclosure for other restrictions regarding SCSI operation.
Power on the first node and the disk arrays.
Find the paths to the SCSI host adapters.
{0} ok show-disks |
Identify and record the two controllers that will be connected to the disk arrays, and record these paths. Use this information to change the SCSI addresses of these controllers in the nvramrc script. Do not include the /sd directories in the device paths.
Edit the nvramrc script to change the scsi-initiator-id for the host adapters of the first node.
For a list of Editor nvramrc editor and keystroke commands, see Appendix B, NVRAMRC Editor and NVEDIT Keystroke Commands.
The following example sets the scsi-initiator-id to 6. The OpenBoot PROM Monitor prints the line numbers (0:, 1:, and so on).
Insert exactly one space after the double quote and before scsi-initiator-id.
{0} ok nvedit 0: probe-all 1: cd /sbus@1f,0/QLGC,isp@3,10000 2: 6 encode-int " scsi-initiator-id" property 3: device-end 4: cd /sbus@1f,0/ 5: 6 encode-int " scsi-initiator-id" property 6: device-end 7: install-console 8: banner [Control C] {0} ok |
Store the changes.
The changes you make through the nvedit command are done on a temporary copy of the nvramrc script. You can continue to edit this copy without risk. After you have completed your edits, save the changes. If you are not sure about the changes, discard them.
To store the changes, type:
{0} ok nvstore {0} ok |
To discard the changes, type:
{0} ok nvquit {0} ok |
Verify the contents of the nvramrc script you created in Step 7.
If the contents of the nvramrc script are incorrect, use the nvedit command to make corrections.
{0} ok printenv nvramrc nvramrc = probe-all cd /sbus@1f,0/QLGC,isp@3,10000 6 encode-int " scsi-initiator-id" property device-end cd /sbus@1f,0/ 6 encode-int " scsi-initiator-id" property device-end install-console banner {0} ok |
Instruct the OpenBoot PROM Monitor to use the nvramrc script:
{0} ok setenv use-nvramrc? true use-nvramrc? = true {0} ok |
Boot the first node, and wait for it to join the cluster.
{0} ok boot -r |
For more information, see Sun Cluster 3.0 System Administration Guide.
On all nodes, verify that the DIDs have been assigned to the disk drives in the disk array.
# scdidadm -l |
Shut down the second node.
# scswitch -S -h nodename # shutdown -y -g 0 |
Power off the second node.
Install the host adapters in the second node.
For the procedure on installing host adapters, see the documentation that shipped with your nodes.
Connect the disk array to the host adapters using differential SCSI cables.
Without allowing the node to boot, power on the second node. If necessary, abort the system to continue with OpenBoot PROM Monitor tasks.
Verify that the second node sees the new host adapters and disk drives.
{0} ok show-disks |
Verify that the scsi-initiator-id for the host adapters on the second node is set to 7.
Use the show-disks command to find the paths to the host adapters connected to these enclosures. Select each host adapter's device tree node, and display the node's properties to confirm that the scsi-initiator-id for each host adapter is set to 7.
{0} ok cd /sbus@1f,0/QLGC,isp@3,10000 {0} ok .properties scsi-initiator-id 00000007 ... |
Boot the second node, and wait for it to join the cluster.
{0} ok boot -r |
On all nodes, verify that the DIDs have been assigned to the disk drives in the disk array.
# scdidadm -l |
Perform volume management administration to add the disk drives in the array to the volume management configuration.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
Use this procedure to replace a StorEdge D1000 disk array. This procedure assumes that you want to retain the disk drives in the disk array you want to replace and retain the references to these same disk drives.
If you want to replace your disk drives, see "How to Replace a StorEdge D1000 Disk Drive".
If possible, back up the metadevices or volumes that reside in the disk array.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
Perform volume management administration to remove the disk array from the configuration.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
Disconnect the SCSI cables from the disk array, removing them in the order shown in Figure 5-4.
Power off, and disconnect the disk array from the AC power source.
For more information, see the documentation that shipped with your disk array.
Connect the new disk array to an AC power source.
For more information, see the documentation that shipped with your disk array.
Connect the SCSI cables to the new disk array by reversing the steps shown in Figure 5-4.
Move the disk drives one at time from the old disk array to the same slot in the new disk array.
Power on the disk array.
On all nodes attached to the disk array, run the devfsadm(1M) command.
# devfsadm |
One at a time, shut down and reboot the nodes connected to the disk array.
# scswitch -S -h nodename # shutdown -y -g 0 -i 6 |
For more information on shutdown, see Sun Cluster 3.0 System Administration Guide.
Perform volume management administration to add the disk array to the configuration.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
Use this procedure to remove a StorEdge D1000 disk array from a cluster. This procedure assumes that you want to remove the references to the disk drives in the enclosure.
Perform volume management administration to remove the disk array from the configuration.
For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.
Disconnect the SCSI cables from the disk array, removing them in the order shown in Figure 5-5.
Power off, and disconnect the disk array from the AC power source.
For more information, see the documentation shipped with your disk array.
Remove the disk array.
Identify the disk drives you need to remove.
# cfgadm -al |
On all nodes, remove references to the disk drives in the disk array you removed in Step 4.
# cfgadm -c unconfigure cN::dsk/cNtXdY # devfsadm -C # scdidadm -C |
If needed, remove any host adapters from the nodes.
For the procedure on removing host adapters, see the documentation that shipped with your nodes.