Each SCI adapter card has a jumper, called the scrubber jumper. This jumper configures the scrubber circuit, which controls link maintenance functions. Figure 1-5 shows its location on the SCI adapter card.
Table 1-1 specifies the appropriate scrubber jumper settings for unswitched and switched SCI networks.
Table 1-1 Scrubber Jumper Settings
Topology |
SCI SBus Card Jumper Settings |
---|---|
Two nodes (unswitched) |
Set one jumper ON and the other jumper OFF in each connected pair of SCI adapter cards. See Figure 1-6 for examples of two-node jumper settings. |
Three or four nodes (switched) |
Set all jumpers ON. |
SCI adapter cards are shipped without a default setting. Therefore, examine the setting on each SCI adapter card and adjust it if necessary. If scrubber jumpers are not set correctly when installed, communication between nodes may experience intermittent faults.