Sun Management Center 3.6 Release Notes

Sun Fire T2000 Bugs

No Indication That the Service Processor Offlined a CPU Prior to Boot on Sun Fire T2000 Systems (6318168)

When a CPU is offlined by the service processor, the CPU's status is not recorded by Sun Management Center. Sun Management Center does record and indicate when a CPU is offlined by the operating system with the psradm command.

Workaround: Use the showcomponents command on the service processor to view CPUs that have been offlined prior to boot.

LED Images for SYS/LOCATE and SYS/SERVICE Appear in Wrong Location on Sun Fire T2000 Systems (6323669)

LED images for SYS/LOCATE and SYS/SERVICE appear in the wrong location of the rear chassis view. The physical placement of these images is between the system controller serial management port and USB ports on Sun Fire T2000 systems.

Workaround: None.

Fan Tray Images for FT0/F0 and FT0/F2 Appear Reversed on Sun Fire T2000 Systems (6323674)

In the top view of Physical View, fan tray images for FT0/F0 and FT0/F2 appear reversed. The descriptions of each fan contradict their image locations when viewed from the front.

Workaround: None.

Erroneous Number of Processors Reported in Some Tables on Sun Fire T2000 Systems (6327350)

The number of processors that is reported in the System table and Hardware Summary table might not match the number of entries of processors listed in the Processors table. The information in the Processors table is correct.

Workaround: None.

Locations of Ethernet Ports in Physical View Do Not Match the Descriptive Locations on Sun Fire T2000 Systems (6327987)

The physical locations of some Ethernet ports in the System-Rear chassis image of Physical View do not match their descriptive locations.

Workaround: None.

Unpopulated Memory Module Slots Print Junk Text in SEEPROM Information Fields on Sun Fire T2000 Systems (6328269)

On Sun Fire T2000 systems, unpopulated memory slots might cause the system to attempt to read the SEEPROM information. As a result, garbled text appears in the following fields:

Workaround: None.

Descriptions for Numeric Voltage Sensors Incorrectly Switched (6328444)

The descriptions for the Numeric Voltage Sensors IOBD/V_+3V3MAIN and IOBD/V_+3V3STBY are switched in the Numeric Voltage Sensors Table.

Workaround: None.

Sun Management Center Displays an Incorrect Platform Name for Sun Fire T2000 Systems (6321787)

Sun Management Center incorrectly displays Sun-Fire-T200 as the platform name for Sun Fire T2000 systems. The Sun Fire T2000 system controller correctly displays Sun-Fire-T2000 as the platform name.

Workaround: None.

Physical View of the ELP Config Reader on Sun Fire T2000 Systems Does Not Display DIMM Location or Correct Status (6334131)

On Sun Fire T2000 systems, the ELP config reader does not display the DIMM memory devices in the Physical View and will not communicate an ERROR status when appropriate for each DIMM. The only operational status that is reported for DIMMs is OK or NOT PRESENT.

Workaround: None.