The environmental requirements for the system are as follows.
Parameter |
Value |
|
---|---|---|
Operating |
|
|
|
Temperature |
5°C to 35°C (41°F to 95°F)--IEC 68-2-1, 68-2-2 |
|
Humidity |
20% to 80% RH, noncondensing; 27 °C max wet bulb--IEC 68-2-2, 68-2-3 |
|
Altitude |
0 to 3000 meters (0 to 10,000 feet)--IEC 68-2-40, 68-2-41 |
|
Vibration |
0.2 gravity (g) peak, 5-500 Hz (swept sine); 0.0002 g2/Hz, 5-500 Hz (random); vertical axis only (castered configuration); vertical and horizontal axes (foot glide configuration)--IEC 68-2-6 |
|
Shock |
4g peak, 11 milliseconds half-sine pulse--IEC 68-2-27 |
Non-Operating |
|
|
|
Temperature |
-20°C to 60°C (-4°F to 140°F)--IEC 68-2-1, 68-2-2 |
|
Humidity |
93% RH, noncondensing at 35°C--IEC 68-2-2, 68-2-3 |
|
Altitude |
0 to 12,000 meters (0 to 40,000 feet)--IEC 68-2-40, 68-2-41 |
|
Vibration |
1g peak, 5-500 Hz (swept sine); 0.002 g2/Hz, 5-500 Hz (random); 3 perpendicular axes--IEC 68-2-6 |
|
Shock |
15g peak, 11 milliseconds half-sine pulse--IEC 68-2-27e |
|
Threshold Impact |
1 m/s--SUN 900-1813 |