The environmental requirements for the system are as follows.
| 
 Parameter  | 
 Value  | 
|
|---|---|---|
| 
 Operating  | 
 
  | 
|
| 
 
  | 
 Temperature  | 
 5°C to 35°C (41°F to 95°F)--IEC 68-2-1, 68-2-2  | 
| 
 
  | 
 Humidity  | 
 20% to 80% RH, noncondensing; 27 °C max wet bulb--IEC 68-2-2, 68-2-3  | 
| 
 
  | 
 Altitude  | 
 0 to 3000 meters (0 to 10,000 feet)--IEC 68-2-40, 68-2-41  | 
| 
 
  | 
 Vibration  | 
 0.2 gravity (g) peak, 5-500 Hz (swept sine); 0.0002 g2/Hz, 5-500 Hz (random); vertical axis only (castered configuration); vertical and horizontal axes (foot glide configuration)--IEC 68-2-6  | 
| 
 
  | 
 Shock  | 
 4g peak, 11 milliseconds half-sine pulse--IEC 68-2-27  | 
| 
 Non-Operating  | 
 
  | 
|
| 
 
  | 
 Temperature  | 
 -20°C to 60°C (-4°F to 140°F)--IEC 68-2-1, 68-2-2  | 
| 
 
  | 
 Humidity  | 
 93% RH, noncondensing at 35°C--IEC 68-2-2, 68-2-3  | 
| 
 
  | 
 Altitude  | 
 0 to 12,000 meters (0 to 40,000 feet)--IEC 68-2-40, 68-2-41  | 
| 
 
  | 
 Vibration  | 
 1g peak, 5-500 Hz (swept sine); 0.002 g2/Hz, 5-500 Hz (random); 3 perpendicular axes--IEC 68-2-6  | 
| 
 
  | 
 Shock  | 
 15g peak, 11 milliseconds half-sine pulse--IEC 68-2-27e  | 
| 
 
  | 
 Threshold Impact  | 
 1 m/s--SUN 900-1813  |