The dimensions and weight of the system are as follows.
Table B-1
|
U.S |
Metric |
Comments |
---|---|---|---|
Height |
18.1 in |
46.0 cm |
20.4 in (51.7 cm) if equipped with floor casters |
Width |
10.3 in |
26.2 cm |
|
Depth |
27.1 in |
68.8 cm |
Power supply handles add 1.2 in (3.1 cm) |
Weight |
118 lb, max |
53 kg, max |
Actual weight depends on the installed options. |
Power Cord |
8.2 ft |
2.5 m |
|
Clearances needed when servicing the system are as follows.
Table B-2
|
U.S |
Metric |
---|---|---|
Front |
36 in |
91.44 cm |
Rear |
36 in |
91.44 cm |
Right |
36 in |
91.44 cm |
Left |
36 in |
91.44 cm |
Top |
36 in |
91.44 cm |
The operating and non-operating environmental requirements for the system are as follows.
Table B-3
Parameter |
Value |
---|---|
Operating |
|
Temperature |
5°C to 35°C (41°F to 95°F)--IEC 68-2-1, 68-2-2 |
Humidity |
20% to 80% RH, noncondensing; 27 °C max wet bulb--IEC 68-2-2, 68-2-3 |
Altitude |
0 to 3000 meters (0 to 10,000 feet)--IEC 68-2-40, 68-2-41 |
Vibration |
0.2 gravity (g) peak, 5-500 Hz (swept sine); 0.0002 g2/Hz, 5-500 Hz (random); vertical axis only (castered configuration); vertical and horizontal axes (foot glide configuration)--IEC 68-2-6 |
Shock |
4g peak, 11 milliseconds half-sine pulse--IEC 68-2-27 |
Declared Noise Emissions |
6.5/6.3 B (operating/idle)--ISO 9296 (LWAd) |
Non-Operating |
|
Temperature |
-20°C to 60°C (-4°F to 140°F)--IEC 68-2-1, 68-2-2 |
Humidity |
93% RH, noncondensing at 35°C--IEC 68-2-2, 68-2-3 |
Altitude |
0 to 12,000 meters (0 to 40,000 feet)--IEC 68-2-40, 68-2-41 |
Vibration |
1g peak, 5-500 Hz (swept sine); 0.002 g2/Hz, 5-500 Hz (random); 3 perpendicular axes--IEC 68-2-6 |
Shock |
15g peak, 11 milliseconds half-sine pulse--IEC 68-2-27e |
Threshold Impact |
1 m/s--SUN 900-1813 |
The system complies with the following specifications.
Table B-4
Category |
Relevant Standards |
---|---|
Safety |
EN60950/IEC950, TUV UL 1950, CB Scheme IEC 950, C22.2 No. 950 from UL |
RFI/EMI |
EN55022/CISPR22 Class B VCCI Class II FCC Part 15 Sub Part B |
Immunity |
EN50082/IEC-1000-2 IEC-1000-3 IEC-1000-4 IEC-1000-5 |
X-ray |
DHHS 21 Subchapter J PTB German X-ray Decree |
The following table provides the electrical specifications for the system.
Table B-5
Parameter |
Value |
---|---|
Input |
|
Nominal Frequencies |
50 Hz or 60 Hz nominal |
Nominal Voltage Range |
100 to 240 VAC |
Maximum Current AC RMS |
6.0 A @ 100 VAC |
AC Operating Range |
90 to 264 Vrms, 47 to 63Hz |
Output |
|
+1.8 to 3.0 VDC* |
3 to 27 A |
+3.3 VDC** |
3 to 34 A |
+5 VDC** |
2 to 30 A |
+12 VDC |
0.5 to 10 A |
-12 VDC |
0 to 0.5 A |
Maximum DC Power Output |
360 Watts |
Maximum AC Power Consumption |
580 Watts |
Maximum Heat Dissipation |
1980 BTUs/hr |
Volt-Ampere Rating |
600 VA with 360 Watt load |
* CPU core voltage. Actual voltage is determined by the specific CPU module(s) installed. |
|
** Combined output power of the +3.3 VDC and +5 VDC outputs must not exceed 170 Watts. |