Sun Enterprise 6500/5500/4500 Systems Installation Guide

Connecting the System to the Network

  1. Connect the network cable to a twisted-pair-to-transceiver interface box.

  2. Connect the interface box with an appropriate cable to a network transceiver.

    Figure 2-7 shows a typical arrangement for connecting the system to an Ethernet network.

  3. For Ethernet cables, determine if the cable has N-type screw-on connectors at the ends.

    • If the Ethernet cable lacks N-type connectors at the ends, use a "vampire" tap to connect the cable to the transceiver. See Figure 2-7. To connect the cable to the transceiver, use instructions provided with the vampire tap.

    • If the Ethernet cable has N-type connectors, connect the Ethernet cable to the transceiver:

    1. Screw the Ethernet coaxial cable into one of the round screw-on type connectors on the transceiver.

      Use either one of the transceiver connectors.

    2. Screw the other end of Ethernet cable into the connector on the transceiver.

  4. Determine if a terminator should be installed. Table 2-1 lists the cabling limitations for Ethernet.

  5. If termination is required, install a 50-ohm terminator in the unused transceiver N connector or at the end of the coaxial cable. Use a female double N-type connector.

    Figure 2-7 shows the elements used in the installation process.

    Figure 2-7 Connecting Twisted Pair Ethernet to N-type Coaxial Cable

    Graphic

Table 2-1 lists the cabling limitations for Ethernet.

Table 2-1 Ethernet Cabling Limitations for N-type Coaxial Cable

Cable Segment 

Length in Meters 

 Notes

Allowed contiguous length of cable segments 

  23.4 [Finite lengths (as constrained by transmission line phenomena). Minimum length = 23.4M; maximum = 500M. If cable falls shorter than one of these values, add cable to achieve next-highest value.]
  70.2 
  117.0 
  500.0 

Distance between transceivers (multiples-of) 

  2.5 [Transceivers are placed at intervals of 2.5 meters, or multiples of 2.5 meters along the Ethernet cable. Example: transceivers are connected 2.5 meters apart, not 2.0 meters. Example: transceivers are connected 15 meters apart (6 multiples of 2.5 meters), not 14.0 meters.]

Minimum length of Ethernet coaxial cable segments 

  23.4 

Maximum length of transceiver "drop" cable 

  50.0 

Minimum length of twisted pair cable 

  no minimum 

Maximum length of twisted pair cable 

  110. 

Figure 2-8 shows an example of a typical network setup. The Sun Enterprise 6500/5500/4500 systems can be any server shown in this figure.

Figure 2-8 Ethernet Cabling Length -- Example Using N-type Cable

Graphic


Note -

Sun equipment conforms to the Ethernet 10/100BASE-T standard, which states that the 10/100BASE-T Link Integrity Test function should always be enabled on both the host and the hub. If you have problems verifying connection between Sun equipment and your hub, verify that your hub also has the link test function enabled. See "Failure of Network Communications", and refer to the manual provided with your hub for more information about the Link Integrity Test function.