Sun Fire X4240 Server Service Manual
820-3835-14
Contents |
1. Sun Fire X4240 Server Overview
1.2 Sun Fire X4240 Server Chassis Overview
1.3 Sun Fire X4240 Front Panel Features
1.4 Sun Fire X4240 Rear Panel Features
1.5 Illustrated Parts Breakdown
2. Preparing to Service the System
2.2 SSD Minimum Required Firmware
2.4 Obtaining the Chassis Serial Number
2.5.1 Powering Off the Server Using the Service Processor Command Line
2.6 Extending the Server to the Maintenance Position
2.7 Removing a Server From the Rack
2.8 Performing Electrostatic Discharge and Antistatic Prevention Measures
2.8.1 Electrostatic Discharge Safety Measures
2.8.1.1 Using an Antistatic Wrist Strap
2.8.1.2 Using an Antistatic Mat
2.8.2 Antistatic Handling Procedure
3. Servicing Customer-Replaceable Devices
3.1 Devices That Are Hot-Pluggable or Hot-Swappable
3.2.1 Sun Fire X4240 Drive Guidelines
3.2.2 Sun Fire X4240 SSD Guidelines
3.2.2.1 SSD Firmware Requirements
3.2.3 Drive Status LED Reference
3.2.4 Removing a Hard Drive or SSD
3.2.5 Installing a Hard Drive or SSD
3.3.1 About Sun Fire X4240 Fans
3.3.2 Fan Module LED Reference
3.3.3 Detecting Fan Module Failure
3.4.1 Detecting Power Supply Failure
3.4.2 Power Supply LED Reference
3.4.4 Installing a Power Supply
3.5 Servicing the DVD/USB Module
3.5.1 Removing the DVD/USB Module
3.5.2 Installing the DVD/USB Module
4. Servicing Motherboard Components
4.1.1 Identifying Faulty DIMMs
4.1.2.3 Single Processor Configuration DDR2 DIMM Placement
4.1.5 Installing Additional DDR2 DIMMs
4.4.1 Sun Fire X4240 PCIe Card Guidelines
4.6 Servicing the Motherboard Assembly
4.6.1 Removing the Motherboard Assembly
4.6.2 Installing the Motherboard Assembly
4.7 Servicetool FRU Update Procedures
4.7.1 Updating FRU Product Information Using ServiceTool
4.7.2 Restoring Product Information From the FRUID PROM
4.7.3 Changing Product Information on the Motherboard Using a File
4.8.1 Processor Fault Remind Button
4.8.3 Installing a Processor FRU
4.8.4 Installing an X-option Processor
4.9 Resetting Passwords and Clearing CMOS NVRAM
4.9.2 Resetting a Service Processor Password From the BIOS Screen
4.9.3 Resetting CMOS NVRAM Using a Jumper
4.10 Recovering From Corrupt Service Processor Software
4.10.1 Reinstalling The Default SP Software Image From The Tools And Drivers CD
4.11 Using the Reset and NMI Switches
5. Servicing Infrastructure Boards and Components
5.1 Servicing the Fan Power Boards
5.1.1 Removing a Fan Power Board
5.1.2 Installing a Fan Power Board
5.2.1 Removing the Drives Cage
5.2.2 Installing the Hard Drive Cage
5.3 Servicing the Hard Drive Backplane
5.3.1 Removing the Hard Drive Backplane
5.3.2 Installing the Hard Drive Backplane
5.4 Servicing the Front Control Panel Light Pipe Assembly
5.4.1 Removing the Front Control Panel Light Pipe Assembly
5.4.2 Installing the Front Control Panel Light Pipe Assembly
5.5 Servicing the Power Distribution Board (PDB)
5.5.1 Removing the Power Distribution Board
5.5.2 Installing the Power Distribution Board
5.6 Servicing the Power Supply Backplane
5.6.1 Removing the Power Supply Backplane
5.6.2 Installing the Power Supply Backplane
5.7.1 Removing the Paddle Card
5.7.2 Installing the Paddle Card
5.8.1 Removing HDD Cables in a SAS Configuration
5.8.2 Installing HDD Cables For a PCI-E Controller
6. Returning the Server to Operation
6.2 Reinstalling the Server in the Rack
6.3 Returning the Server to the Normal Rack Position
A.1 Serial Management Port Connector
A.2 Network Management Port Connector
A.5 Gigabit Ethernet Connectors
B. BIOS Power-On Self-Test (POST) Codes
B.2 How BIOS POST Memory Testing Works
B.3 Redirecting Console Output
C.1.2 BIOS Setup Screens Overview
C.2.2 BIOS Advanced Menu Screens
C.2.3 BIOS PCI/PnP Menu Screens
C.2.5 BIOS Security Menu Screens
C.2.6 BIOS Chipset Menu Screens
Copyright © 2010, Oracle and/or its affiliates. All rights reserved.