Sun Logo


Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4140, X4240, and X4440 Servers

820-5754-11



Contents

Preface

1. Introduction

ILOM 2.0 Features Supported

2. Firmware Update Procedures

Overview

ILOM/System BIOS Firmware Update Summary

LSI Disk Controller BIOS Update Summary

Obtaining the Service Processor’s IP Address

Identifying Current Firmware Versions

Using the CLI Through the Management Ethernet Port

Using the CLI Through the Serial Port

Using the Web Interface

Downloading New Firmware

Flashing the ILOM/BIOS Firmware

Flashing the Firmware with the ILOM GUI

Flashing the Firmware With the ILOM CLI

Flashing the Firmware With the Sun xVM Ops Center

Flashing the Firmware With the Web GUI

Clearing CMOS Settings (Optional)

Resetting the Service Processor

Downgrading to a Previous ILOM Release

Updating Your LSI Firmware

JavaRConsole Method With ISO Image

Local Method

More on Updating the LSI Firmware

3. Sensor Definitions

System Sensors

sys.intsw

sys.acpi

sys.nmi

sys.power.btn

sys.reset.btn

sys.locate.btn

CPU 0 Discrete Sensors

p0.prsnt

p0.prochot

CPU 1 Discrete Sensors

p1.prsnt

p1.prochot

CPU 2 Discrete Sensors (Sun Fire X4440 Only)

p2.prsnt

p2.prochot

CPU 3 Discrete Sensors (Sun Fire X4440 Only)

p3.prsnt

p3.prochot

Power Supply Sensors

ps0.prsnt

ps0.vinok

ps0.pwrok

ps1.prsnt

ps1.vinok

ps1.pwrok

Fan Control Temperature Sensors

sys.t_amb

p0.t_core

p1.t_core

p2.t_core

p3.t_core

Other Temperature Sensors

mb.t_core

mezz.t_core

Mainboard Voltage Sensors

mb.v_bat

mb.v_+3v3stby

mb.v_+3v3

mb.v_+5v

mb.v_+12v

mb.v_+1v5

mb.v_+1v2ht

mb.v_+1.4

Mezzanine Voltage Sensors (Sun Fire X4440 Only)

mezz.v_+3v3stby

mezz.v_+3v3

mezz.v_+12v

mezz.v_+1v2ht

CPU Voltage Sensors

pX.v_vddcore

pX.v_+1v8

pX.v_+0v9

pX.v_vddnb

Fan Presence Sensors

fbX.fmY.prsnt

Fan Speed Sensors

fbX.fmY.fZ.speed

I/O Sensors

hddX.prsnt

hddX.fail

hddX.ok2rm