Sun Fire X4600/X4600 M2 Servers Diagnostics Guide
|
|
A
B
back panel
LED functions 40
LED locations 40
BIOS
changing POST options 27
event logs 21
POST code checkpoints 32
POST codes 30
POST overview 25
redirecting console output for POST 26
Bootable Diagnostics CD 18
C
comments and suggestions xiv
component inventory
viewing with ILOM SP GUI 50
viewing with IPMItool 68
configurations supported for DIMMs 12
CPU
fault LED 44
module attention LED 44
D
diagnostic software
Bootable Diagnostics CD 18
SunVTS 17
DIMMs
error handling 7
fault LEDs 10, 1
isolating errors 14
population rules 12
supported configurations 12
E
emergency shutdown 5
error handling
correctable 78
DIMMs 7
hardware errors 86
mismatching processors 85
parity errors 80
system errors 83
uncorrectable errors 75
external inspection 4
external LEDs 37
F
fan tray fault LEDs 41
finding sensor names 67
Front Fan Fault LED 39
front panel
LED functions 39
LED locations 38
FRU inventory
viewing with ILOM SP GUI 50
viewing with IPMItool 68
G
gathering service visit information 3
general troubleshooting guidelines 3
graceful shutdown 5
GRASP board power status LED 44
guidelines for troubleshooting 3
H
hard disk drive status LEDs 39
I
ILOM SP GUI
general information 45
serial connection 46
time stamps 49
viewing component inventory 50
viewing sensors 52
viewing SP event log 47
inspection
external 4
internal 5
See
See
internal inspection 5
internal LEDs 42
IPMItool
changing default password 60
clearing SP SEL 66
configuring SSH key 60
connecting to server 59
enabling anonymous user 59
general information 58
LED modes 71
LED sensor groups 71
LED sensor IDs 69
location of package 58
man page 58
setting LED status 69
using scripts for testing 72
using SDR cache 67
viewing component inventory 68
viewing LED status 69
viewing sensor status 61
viewing SP SEL 65
isolating DIMM ECC errors 14
L
LEDs
back panel functions 40
back panel locations 40
CPU fault 44
CPU module attention 44
DIMM fault 44
external 37
Fan Tray fault 41
Front Fan Fault 39
front fan fault functions 41
front panel functions 39
front panel locations 38
GRASP Board Power Status 44
Hard Disk Drive Status 39
internal 42
Locate 39
modes 71
Power Supply Fault 39
Power Supply Status 40
Power/OK 39
sensor groups 71
sensor IDs 69
Service Action Required 39
setting status with IPMItool 69
System Overheat Fault 39
viewing status with IPMItool 69
Locate LED and button 39
M
mapping sensor numbers to sensor names 67
P
PERR 80
population rules for DIMMs 12
POST
changing options 27
code checkpoints 32
codes table 30
overview 25
redirecting console output 26
Power button location 5
power off procedure 5
power supply
Fault LED 39
status LED 40
Power/OK LED 39
See
R
redirecting console output 26
related documentation xii
S
safety guidelines xi
See
sensor IDs for LEDs 69
sensor number formats 67
sensors
viewing with ILOM SP GUI 52
viewing with IPMItool 61
serial connection to ILOM SP 46
SERR 83
Service Action Required LED 39
See
shutdown procedure 5
SP event log
viewing with ILOM SP GUI 47
SP SEL
clearing with IMPItool 66
sensor numbers and names 67
time stamps 49
using SDR cache 67
viewing with IPMItool 65
Sun Fire X4200
Power button 5
SunVTS
Bootable Diagnostics CD 18
documentation 18
logs 19
overview 17
System Overheat Fault LED 39
T
time stamps in ILOM SP SEL 49
troubleshooting
flow chart 2
guidelines 3
U
Sun Fire X4600/X4600 M2 Servers Diagnostics Guide
|
819-4343-12
|
|
Copyright © 2006, Sun Microsystems, Inc. All Rights Reserved.