A P P E N D I X  B

Status Indicator LEDs

This appendix contains information about the locations and behavior of the LEDs on the server. It describes the external LEDs that can be viewed on the outside of the server and the internal LEDs that can be viewed only with the main cover removed.


External Status Indicator LEDs

See the following figures and tables for information about the LEDs that are viewable on the outside of the server.

Front Panel LEDs

FIGURE B-1 Sun Fire X4150 Server Front Panel LEDs



Figure Legend

1

Locator LED/Locator button: (White)

5

Hard drive map

2

Service Required LED: (Amber)

6

Rear PS LED: (Amber) Power supply fault

3

Power/OK LED: (Green)

7

System Over Temperature LED: (Amber)

4

Power button

8

Top Fan LED: (Amber) Service action required on fans


FIGURE B-2 Sun Fire X4250 Server Front Panel LEDs


FIGURE B-3 Sun Fire X4450 Server Front Panel LEDs



Figure Legend (applies to both X4250 and X4450)

1

Locator LED/Locator button: (White)

5

Rear PS LED: (Amber) Power supply fault

2

Service Required LED: (Amber)

6

System Over Temperature LED: (Amber)

3

Power/OK LED: (Green)

7

Top Fan LED: (Amber) Service action required on fans

4

Power button

8

Hard drive map


Back Panel LEDs

FIGURE B-4 Sun Fire X4150 Server Back Panel LEDs


FIGURE B-5 Sun Fire X4250 and X4450 Server Back Panel LEDs



Figure Legend (applies to all servers)

1

Power Supply LEDs:

3

Ethernet Port LEDs

 

  • Power Supply OK: (Green)

 

Left side: Green indicates link activity

 

  • Power Supply Fail: (Amber)

 

Right side:

 

  • AC OK: (Green)

 

  • Green: Link is operating at maximum speed

2

System LEDs

 

  • Amber: Link is operating at less than maximum speed.

 

  • Locator LED Button: (White)

 

 

 

  • Service Required LED: (Amber)

 

 

 

  • Power OK LED: (Green)

 


Hard Drive LEDs

FIGURE B-6 Hard Drive LEDs



Figure Legend

1

Ready to remove LED: Blue - Service action is allowed

2

Fault LED: Amber - Service action is required

3

Status LED: Green - Blinks when data is being transferred



Internal Status Indicator LEDs

The server has internal status indicators on the motherboard.

When you press the Remind button, if there is a problem with a DIMM, the corresponding DIMM Fault LED flashes. See DIMM Fault LEDs for details.

When you press the Remind button, if there is a problem with a CPU, the corresponding CPU Fault LED flashes.



Note - The DIMM Fault and CPU Fault LEDs operate on stored power for up to a minute when the system is powered down, even after the AC power is disconnected, and the motherboard is out of the system. The stored power lasts for about half an hour.


FIGURE B-7 Remind Button and DIMM LEDs on X4150 and X4250 Motherboard


Figure showing remind button and motherboard DIMMs and LEDs for X4150 and X4250.

FIGURE B-8 Remind Button and DIMM LEDs on X4450 Motherboard


Figure showing remind button and motherboard DIMMs and LEDs for X4450.

FIGURE B-9 Remind Button and CPU LEDs on X4150 and X4250 Motherboard


Figure showing remind button and motherboard CPU LEDs for X4150 and X4250.

FIGURE B-10 Remind Button and CPU LEDs on X4450 Motherboard


Figure showing remind button and motherboard CPU LEDs for X4450.