Translate Network Interface Card PCI Bus Number to Physical Network Port
|
This appendix provides information to help you identify the appropriate network interface card to configure for the VMware service console.
To translate the PCI bus numbering for network interface cards populated in a Sun Fire X4170, X4270 or X4275 Server, refer to the following tables.
TABLE A-4 Sun Fire X4170 Server Bus Numbering Translations for X7280A-2
PCI Bus:Device:Function
|
PCI Slot
|
RJ-45 Port
|
d:0:0/d:0:1
|
0
|
0/1
|
13:0:0/13:0:1
|
1
|
0/1
|
19:0:0/19:0:1
|
2
|
0/1
|
TABLE A-5 Sun Fire X4170 Server Bus Numbering Translations for X4446A-2
PCI Bus:Device:Function
|
PCI Slot
|
RJ-45 Port
|
f:0:0/f:0:1/10:0:0/10:0:1
|
0
|
0/1/2/3
|
15:0:0/15:0:1/16:0:0/16:0:1
|
1
|
0/1/2/3
|
1b:0:0/1b:0:1/1c:0:0/1c:0:1
|
2
|
0/1/2/3
|
TABLE A-6 Sun Fire X4270 and X4275 Servers Bus Numbering Translations for X7280A-2
PCI Bus:Device:Function
|
PCI Slot
|
RJ-45 Port
|
13:0:0/13:0:1
|
0
|
0/1
|
21:0:0/21:0:1
|
1
|
0/1
|
2f:0:0/2f:0:1
|
2
|
0/1
|
d:0:0/d:0:1
|
3
|
0/1
|
1b:0:0/1b:0:1
|
4
|
0/1
|
29:0:0/29:0:1
|
5
|
0/1
|
TABLE A-7 Sun Fire X4270 and X4275 Servers Bus Numbering Translations for X4446A-2
PCI Bus:Device:Function
|
PCI Slot
|
RJ-45 Port
|
15:0:0/15:0:1/16:0:0/16:0:1
|
0
|
0/1/2/3
|
23:0:0/23:0:1/24:0:0/24:0:1
|
1
|
0/1/2/3
|
31:0:0/31:0:1/32:0:0/32:0:1
|
2
|
0/1/2/3
|
f:0:0/f:0:1/10:0:0/10:0:1
|
3
|
0/1/2/3
|
1d:0:0/1d:0:1/1e:0:0/1e:0:1
|
4
|
0/1/2/3
|
2b:0:0/2b:0:1/2c:0:0/2c:0:1
|
5
|
0/1/2/3
|
Sun Fire X4170, X4270, and X4275 Servers Linux, VMware, Solaris, and OpenSolaris Operating Systems Installation Guide
|