Using ILOM to Monitor the Host
This section describes the sensors and indicators that can be accessed through the
ILOM.
Sensors report physical information about the server, including voltages, temperatures, fan speeds, and
installation and removal of components.
Indicators report important server conditions.
All sensors and indicators are IPMI-compliant.
Table 2 System ILOM Sensors
|
|
/SYS/DBP/HDDX/FAIL |
HDDX Predictive Failure |
/SYS/DBP/PRSNT |
Disk Backplane Present |
/SYS/FP/PRSNT |
Front Panel Indicator
Module Present |
/SYS/FTX/FMY/FZ/SPEED |
Front Fan Board X Fan Module Y Fan Z Speed in
RPMs |
/SYS/FTX/FMY/PRSNT |
Front Fan Board X Fan Module Y Present |
/SYS/INTSW |
Intrusion Switch Tripped |
/SYS/MB/T_AMBX |
Motherboard Sensor X
Ambient Temperature in Degrees Celsius |
/SYS/MB/V_+12V |
Motherboard 12V Main Input |
/SYS/MB/V_+1V2 |
Motherboard 1.2V Core Input for Motherboard |
/SYS/MB/V_+1V5 |
Motherboard
1.5V Core Input |
/SYS/MB/V_+2V5 |
Motherboard 2.5V Core Input |
/SYS/MB/V_+3V3 |
Motherboard 3.3V Main Input |
/SYS/MB/V_+3V3AUX_R |
Motherboard Standby Devices 3.3V
Auxiliary Input |
/SYS/MB/V_+5V |
Motherboard 5V Main Input |
/SYS/MB/V_-12V |
Motherboard -12V Main Input |
/SYS/MB/V_BAT |
Motherboard Battery Voltage |
/SYS/PSX/PRSNT |
Power Supply X
Present |
/SYS/PSX/PWROK |
Power Supply X Supplying Power |
/SYS/PSX/VINOK |
Power Supply X AC Input Available |
/SYS/PX/CARDFAIL |
CPU Module X
Failure |
/SYS/PX/PROCHOT |
CPU Module X Overheating (split-plane modules only) |
/SYS/PX/PRSNT |
CPU Module X Present |
/SYS/PX/T_AMB |
CPU Module X Ambient
Temperature in Degrees Celsius |
/SYS/PX/T_CORE |
CPU Module X Core Temperature in Degrees Celsius |
/SYS/PX/V_+0V9VTT |
CPU Module X 0.9V
VTT Input |
/SYS/PX/V_+12V |
CPU Module X !2V Main Input |
/SYS/PX/V_+1V2 |
CPU Module X 1.2V Core Input |
/SYS/PX/V_+1V8 |
CPU
Module X 1.8V Core Input |
/SYS/PX/V_+2V5 |
CPU Module X 2.5V Core Input |
/SYS/PX/V_+3V3AUX_R |
CPU Module X
3.3V Auxiliary Input |
/SYS/PX/V_CORE |
CPU Module X Core Voltage |
/SYS/PX/V_NB |
CPU Module X 5V Main Input
(split-plane modules only) |
|
Table 3 System ILOM Indicators
|
|
/SYS/DBP/HDDX/SERVICE |
Service LED for
HDD X is lit. |
/SYS/FTX/FMY/SERVICE |
Service LED for Front Fan Board X Fan Module Y
is lit |
/SYS/PX/CARD/SERVICE |
Service LED for CPU Module X is lit |
/SYS/PX/DY/SERVICE |
Service LED for CPU
Module X DIMM Y is lit |
/SYS/PX/SERVICE |
Service LED for CPU on CPU Module
X is lit |
/SYS/FAN_FAULT |
Fan Fault LED on Front Panel is lit |
/SYS/LOCATE |
Locate LEDs are lit |
/SYS/POWER |
Power
LED is lit |
/SYS/PSU_FAULT |
PSU Fault Detected |
/SYS/SERVICE |
Front Panel Service LED is lit |
/SYS/TEMP_FAULT |
Temperature Fault Detected |
|