A P P E N D I X  A

System Specifications

This Appendix contains the following specifications for the Sun Fire X2270 Server.


A.1 Physical Specifications

TABLE A-1 lists the physical specifications for the Sun Fire X2270 Server.


TABLE A-1 Sun Fire X2270 Server Physical Specifications

Specification

British

Metric

Height

1.7 inches

43 mm

Width

17.2 inches

436 mm

Depth

25.6 inches

650 mm

Weight

27.28 lbs (minimum configuration options)

29.04 lbs (maximum configuration options)

12.4 kg

13.2 kg



A.2 Power Specifications

Maximum continuous power is 600 W. Other power specifications are shown in the following tables.


TABLE A-2 AC Input Voltage Rating

Parameter

Minimum

Rated

Maximum

Voltage

90 Vrms

100-127/200-240 Vrms

264 Vrms

Frequency

47 Hz

50/60 Hz

63 Hz



TABLE A-3 Input Current

Current Type

Values

Maximum input current

8.6 Amps max @ 100 Vac; 4.3 Amps max @ 200 Vac, full load

Maximum inrush current

60 Amps



A.3 Environmental Specifications

Environmental specifications for the Sun Fire X2270 Server are shown in TABLE A-4.


TABLE A-4 Sun Fire X2270 Server Environmental Specifications

Specification

State

British

Metric

Humidity

Operating

7%-93% RH non-condensing, 80.6˚ F max wet bulb

7%-93% RH non-condensing, 38˚ C max wet bulb

 

Nonoperating

93% RH, non-condensing, 100.4˚ F max wet bulb

93% RH, non-condensing, 43˚ C max wet bulb

Vibration

Operating

0.12 G x-y, 0.17 G z;
5-500 Hz sine

 

 

Nonoperating

0.3 G x-y, 0.6 G z;
5-500 Hz sine

 

Shock

Operating

3.5 G; 11 msec. half-sine

 

Temperature

Operating

36˚ F to 100˚ F

2˚ C to 35˚ C

 

Nonoperating

-40˚ F to 154˚ F

-40˚ C to 68˚ C

Maximum operating temperature derating

 

-1.8˚ F for every 985 ft. in altitude

-1˚ C for every 300 m in altitude

Altitude

Operating

max 9,843 ft

max 3,000 m



A.4 Serial Connector Pin Assignments

The serial management port connector is an RS-232-F RJ-45 type connector located on the server back panel.

FIGURE A-1 Serial Management Port Pin Configuration


Diagram of a serial connector, showing its 8 pins.


TABLE A-5 Serial Management Port Pin Assignments

Pin Number

Pin Name

Description

1

RTS

Ready to send

2

DTR

Data terminal ready

3

TXD

Transmit data

4

GND

Ground

5

GND

Ground

6

RXD

Receive data

7

DSR

Data send ready

8

CTS

Clear to send