Hardware Installation

Overview of the Sun Blade Storage Module M2

System Requirements

Installing the Storage Module Into the Chassis

Storage Module Indicators

Assigning and Managing Storage

Product Notes

Overview of the Sun Blade Storage Module M2 Product Notes

Supported Firmware, Hardware and Software

Hardware Issues

Solaris Operating System Issues

Linux Operating System Issues

Administration

Assigning Storage to Hosts

SAS Device Access to the Chassis SAS-2 Domain

Host Access to Storage Module Resources Using the Sun Blade Zone Manager

System Requirements

How to Assign Storage to Hosts Using the CMM ILOM Web Interface

How to Assign Storage to Hosts Using the CMM ILOM CLI

Managing Storage

Performing Maintenance and Hot Plug Actions

Importing Existing Virtual Drives to a Replacement REM

Storage Module Sensors and Indicators

Troubleshooting

Service

Introduction to the Sun Blade Storage Module M2

Maintaining the Sun Blade Storage Module M2

Diagnosing Storage Module Faults

Specifications

Index

How to Assign Storage to Hosts Using the CMM ILOM CLI

Before You Begin

  1. Open a terminal window and establish an ssh connection to the CMM by entering the following command:

    # ssh –l accountname cmm_ip

    Where accountname is the name of a user account with Administrator privileges (such as root) and cmm_ip is the IP address of the CMM.

    The login prompt is displayed.

  2. Log in.

    For example:

    /hostname/login: accountname

    password: yourpassword

    After you have successfully logged in, the prompt will be displayed:

    –>

  3. Confirm that you have the minimum CMM ILOM firmware version required for zoning (as described in System Requirements) by entering the command:

    –> version

    Example output might look like:

    version SP firmware version: 3.0.10.15.a
    SP firmware build number: 201022
    SP firmware date: Mon Mar 29 10:39:46 EST 2010
    SP filesystem version: 0.1.9

    If you do not have the minimum version required, update the CMM ILOM firmware before continuing.

  4. Change directories to sas_zoning by entering the command:

    –> cd /STORAGE/sas_zoning/

  5. Check to see if sas_zoning is enabled by entering the command:

    –> show

    Example output might look like:

    /STORAGE/sas_zoning
        Targets:
    
        Properties:
            zone_management_state = disabled
            reset_password_action = (Cannot show property)
            reset_access_action = (Cannot show property)
    
        Commands:
            cd
            set
            show
    
    ->
  6. If zone_management_state = disabled, enable zoning by entering:

    –> set zone_management_state=enabled

    You will see a warning. You must enter y when prompted to enable zoning.

    ********* WARNING *********
    Enabling CMM zone management will result in the clearing of all zoning
    configuration in the installed chassis SAS hardware, and any SAS I/O
    in progress will be interrupted.
    
    Are you sure you want to enable CMM zone management  (y/n)? y
    Set 'zone_management_state' to 'enabled'
    
    ->
  7. Identify your SAS-2 server modules, NEMs and storage modules by entering:

    –> show –level all

    You will see a listing of all blades and SAS-2 domain storage resources in the chassis. Make a note of where devices and hosts are and decide how you will divide your storage resources. The following examples will help you interpret the list.

    • The first listing is an example of what's actually in the chassis (blades and NEMs). BL and NEM numbers represent physical slot numbers in the chassis. Empty chassis blade slots will not be shown:

      /STORAGE/sas_zoning
          Targets:
              BL0
              BL1
              BL2
              BL3
              BL4
              BL5
              BL6
              BL7
              BL8
              BL9
              NEM0
              NEM1
      
          Properties:
              zone_management_state = enabled
              reset_password_action = (Cannot show property)
              reset_access_action = (Cannot show property)
    • Example listing for a host blade:

       /STORAGE/sas_zoning/BL0
          Targets:
      
          Properties:
              add_storage_access = (Cannot show property)
              remove_storage_access = (Cannot show property)

      Note - Storage internal to the server module, or connected to the server's PCIe ExpressModule accessory slots will not be shown and cannot be zoned using the CMM ILOM utility.


    • Example listing for a storage module. HDD numbers represent physical slot numbers in the storage module. Empty HDD slots will not be shown:


      Note - HDD applies to either mechanical or solid-state disk drives.


      /STORAGE/sas_zoning/BL2
          Targets:
              HDD0
              HDD1
              HDD2
              HDD3
              HDD4
              HDD5
              HDD6
              HDD7
      
          Properties:
    • Example listing for a storage module hard disk drive:

       /STORAGE/sas_zoning/BL2/HDD0
          Targets:
      
          Properties:
              type = Hard Disk
              disk_type = SAS
              wwn = 0x5000c50003d3a765, 0x5000c50003d3a766
              sas_speed = 6.0 Gbps
              add_host_access = (Cannot show property)
              remove_host_access = (Cannot show property)
    • Example listing for a NEM. The NEM number represents the physical NEM slot number in the chassis:

       /STORAGE/sas_zoning/NEM0
          Targets:
              SAS
      
          Properties:
    • Example listing for a SAS-NEM's external SAS ports:

       /STORAGE/sas_zoning/NEM0/SAS
          Targets:
              PORT0
              PORT1
              PORT2
              PORT3
      
          Properties:
    • Example listing for one of the external ports of a SAS-NEM. PORT number represents external physical SAS-NEM port labeling:

       /STORAGE/sas_zoning/NEM0/SAS/PORT0
          Targets:
      
          Properties:
              connected = false
              wwn = (none)
              sas_speed = (none)
              add_host_access = (Cannot show property)
              remove_host_access = (Cannot show property)

      Note - At the release of this document, there is no support for connecting external SAS storage to a SAS-NEM's external SAS ports. Refer to the NEM Product Notes for the latest information on support for the external SAS ports.


  8. Assign storage to a host. Assignment is done on an individual storage device basis. Choose a method described in the following examples:

    Note - Access assignment is mutual. You can assign a storage device to a host, or a host to a storage device. The result is the same.


    • Method 1—Command examples for assigning storage module devices to a server module:
      cd STORAGE/sas_zoning/BL0
      Use the cd command to access the host server module that will be assigned storage.
      set add_storage_access=/CH/BL2/HDD0
      Assign HDD0 of the storage module in blade slot 2 to the current host.
      set add_storage_access=/CH/BL2/HDD0,/CH/BL2/HDD1
      Or, assign multiple devices in a single command line. Use the full path to the device and separate each device with a comma (no space).
      show
      
      /STORAGE/sas_zoning/BL0
        Targets:
            0       (/CH/BL2/HDD0)
            1       (/CH/BL2/HDD1)
      Use the show command to confirm assigned devices to the current host.
    • Method 2—Command examples for assigning a server module to storage module devices:
      cd /STORAGE/sas_zoning/BL2/HDD0
      Use the cd command to access the storage module device (in this case HDD0).
      set add_host_access=/CH/BL0
      Assign the current device (HDD0) of the storage module to the host in blade slot 0.
      show
      
      /STORAGE/sas_zoning/BL2/HDD0
         Targets:
            0       (/CH/BL0)
      Use the show command to confirm assignment of the current device.

    Removing storage can be done using the methods described above and changing the add_storage_access or add_host_access commands to remove_storage_access or remove_host_access.

  9. Save your CMM ILOM configurations to a backup file. Change to the /SP/config directory.

    -> cd /SP/config

  10. If you want sensitive data, such as user passwords, SSH keys, certificates, and so forth, to be backed up, you must provide a passphrase.

    -> set passphrase=passphrase

  11. To initiate the Backup operation, enter the command:

    -> set dump_uri= transfer_method://username:password@ipaddress_or_hostname/directorypath/filename.config

    Where:

    • transfer_method can be tftp, ftp, sftp, scp, http, or https.

    • username is the name of the user account on the remote system. (username is required for scp, sftp, and ftp. username is not used for TFTP, and it is optional for HTTP and HTTPS.)

    • password is the password for the user account on the remote system. (password is required for SCP, SFTP, and FTP. password is not used for TFTP, and it is optional for HTTP and HTTPS.)

    • ipaddress_or_hostname is the IP address or the host name of the remote system.

    • directorypath is the storage location on the remote system.

    • filename is the name assigned to the backup file.

    For complete instructions on using ILOM Backup/Restore, refer to your Oracle Integrated Lights Out Manager (ILOM) 3.0 CLI Procedures Guide.

    Once you have backed-up your CMM ILOM configurations, proceed to your host(s) to format and create volumes for host-assigned disks.

See Also