JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Blade Storage Module M2 Product Documentation
search filter icon
search icon

Document Information

Preface

Product Information Web Site

Related Books

About This Documentation (PDF and HTML)

Documentation Comments

Change History

Hardware Installation

Overview of the Sun Blade Storage Module M2

System Requirements

Installing the Storage Module Into the Chassis

Storage Module Indicators

Assigning and Managing Storage

Product Notes

Overview of the Sun Blade Storage Module M2 Product Notes

Supported Firmware, Hardware and Software

Hardware Issues

Solaris Operating System Issues

Linux Operating System Issues

Administration

Assigning Storage to Hosts

Managing Storage

Management Term Definitions

Overview of Storage Module Management

Management Options Using the CMM ILOM

Management Options Using the Sun Storage 6Gb SAS REM RAID HBA (SGX-SAS6-R-REM-Z)

Management Options Using the Sun Storage 6Gb SAS REM HBA (SGX-SAS6-REM-Z)

Performing Maintenance and Hot Plug Actions

Importing Existing Virtual Drives to a Replacement REM

Storage Module Sensors and Indicators

Troubleshooting

Service

Introduction to the Sun Blade Storage Module M2

Maintaining the Sun Blade Storage Module M2

Diagnosing Storage Module Faults

Specifications

Index

Management Options Using the Sun Storage 6Gb SAS REM HBA (SGX-SAS6-REM-Z)

The Sun Storage 6Gb SAS REM HBA (SGX-SAS6-REM-Z) is a SAS-2 RAID Expansion Module based on the LSI Fusion-MPT IR (Integrated RAID) technology. Includes LSI MegaRAID Storage Manager (MSM) software, a command line interface (using SAS2IRCU or the BIOS-based LSI Configuration Utility). Basic management options include (refer to the MegaRAID documentation for a complete list):

Option/Task
LSI BIOS Config
MSM
CLI
Create/Delete RAID configuration (support for RAID levels 0, 1, and 10).
X
X
X
Set a boot device
X
Display and/or change status of a controller, an enclosure or a drive
X
X
Display status only
Activate IR volume (reactivate existing virtual drives, see note below)
X
X
Locate a drive
X
X
X
Upgrade REM firmware
X
X (SAS2Flash)
Save configurations to a file
X
Check data consistency
X
X
X
View events (disks and storage module voltage/temperature events)
X
X
X
Command scripting
X
Remote management
X
X

Note - If your REM fails, but the drives are good, you can install an identical replacement REM and import the existing virtual drive configurations. For information about importing existing virtual drives, see Importing Existing Virtual Drives to a Replacement REM.


Complete information for using the REM management software to perform storage module tasks is included in the LSI MegaRAID SAS Software User's Guide. This manual is available on the LSI support site at:

http://www.lsi.com/support/sun/