Exit Print View

Sun Datacenter InfiniBand Switch 72 User’s Guide

Get PDF Book Print View
 

Document Information

Using This Documentation

Related Documentation

Documentation, Support, and Training

Documentation Feedback

Installing the Switch

Understanding Switch Specifications

Routing Service Cables

Understanding InfiniBand Cabling

Understanding the Installation

Shipping Carton Contents

Install the Switch in the Rack

Powering On the Switch

Connecting InfiniBand Cables

Verifying the InfiniBand Fabric

Discover the InfiniBand Fabric Topology

Perform Diagnostics on the InfiniBand Fabric

Validate the InfiniBand Fabric and Report Errors

Administering the Switch

Troubleshooting the Switch

Administrative Command Overview

Monitoring the Hardware

Monitoring the InfiniBand Fabric

Controlling the Hardware

Controlling the InfiniBand Fabric

Servicing the Switch

Understanding Service Procedures

Servicing the Power Supplies

Servicing the Fans

Servicing the InfiniBand Cables

Servicing the Battery

Upgrading the Firmware

Index

Discover the InfiniBand Fabric Topology

The ibnetdiscover command enables you to see the InfiniBand fabric topology and build a topology file which is used by the OpenSM Subnet Manager.

  1. Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this procedure.

    See Installation Sequence.

  2. On the management controller, type:

    # ibnetdiscover
    #
    # Topology file: generated on Thu Aug 13 18:16:02 2009
    #
    # Max of 2 hops discovered
    # Initiated from node 0021283a8620b0f0 port 0021283a8620b0f0
    vendid=0x2c9
    devid=0xbd36
    sysimgguid=0x21283a8620b0f3
    switchguid=0x21283a8620b0f0(21283a8620b0f0)
    Switch  36 "S-0021283a8620b0f0"         # "Sun DCS 72 QDR FC switch o4nm2-72p-2" enhanced port 0 lid 25 lmc 0
    [36]    "S-0021283a8620b0d0"[4]         # "Sun DCS 72 QDR switch 1.2(LC)" lid 23 4xQDR
    [35]    "S-0021283a8620b0b0"[5]         # "Sun DCS 72 QDR switch 1.2(LC)" lid 21 4xQDR
    [34]    "S-0021283a8620b0d0"[6]         # "Sun DCS 72 QDR switch 1.2(LC)" lid 23 4xQDR
    .
    .
    .
    vendid=0x2c9
    devid=0xbd36
    sysimgguid=0x21283a8620b0e3
    switchguid=0x21283a8620b0e0(21283a8620b0e0)
    Switch  36 "S-0021283a8620b0e0"         # "Sun DCS 72 QDR switch 1.1(FC)" base port 0 lid 24 lmc 0
    [22]    "S-0021283a8620b0c0"[18]                # "Sun DCS 72 QDR switch 1.2(LC)" lid 22 4xQDR
    .
    .
    .
    #

    Note - The output for your InfiniBand fabric will differ from that in the example.


  3. Perform InfiniBand fabric diagnostics.

    See Perform Diagnostics on the InfiniBand Fabric.

Related Information