A P P E N D I X  A

SCSI Array Specifications

This appendix provides the specifications for the Sun StorEdge 3310 SCSI array. The topics covered are:


A.1 Physical Specifications

TABLE A-1 Sun StorEdge 3310 SCSI Array Physical Specifications

Description

Desktop

Rackmount

Height

3.64 in./ 9.25 cm.

2U (3.5 in./ 8.89 cm.)

Width

19 in./ 48.26 cm.

17.56 in./ 44.60 cm. (body)

Depth

Main chassis 18 in./ 45.72 cm.

 

To back of power supply:

20 in./ 50.8 cm.

 

To back of power supply handle:

21 in./ 53.34 cm.

Main chassis 18 in./ 45.72 cm.

 

To back of power supply:

20 in./ 50.8 cm.

 

To back of power supply handle:

21 in. / 53.34 cm.

Weight Sun StorEdge 3310 (fully loaded)

63.2 lbs. / 28.7 kg. with 300-GB drives

 

57.2 lbs. / 26.0 kg. with 300-GB drives

 

Weight (fully loaded Sun StorEdge 3310 JBOD or expansion unit)

60.0 lbs. / 27.2 kg. with 300-GB drives

 

54.0 lbs. / 24.5 kg. with 300-GB drives

 




Note - Add 12.8 lbs. (5.8 kg.) for packaging if you want to know the shipping weight of your array or expansion unit.




A.2 Summary of Sun StorEdge 3310 SCSI Array Specifications

TABLE A-2 Summary of Sun StorEdge 3310 SCSI Array Specifications

Feature

Description

General

  • 12 hot-pluggable drives in a 2U high (3.5-inch) chassis
  • Ultra 160 SCSI buses
  • Autosensing AC or DC power supplies
  • Dual-host access in certain configurations

Density

  • Up to 10.8 TB (using 300-GB drives) in a RAID array
  • 21-inch chassis depth
  • RAID supports one expansion chassis in a dual-host configuration, or two expansion chassis in a single-host configuration

Reliability

  • Redundant hot swappable FRUs
  • Single or redundant active/active hot-swappable RAID controllers
  • Redundant hot swappable event-monitoring units (EMU)
  • N+1 hot swappable power and cooling
  • NEBS Level 3 and HALT test certified; Designed to meet 99.999% reliability

RAID System
Storage Resource Management

  • Web-based 10/100BASE-T Ethernet support
  • Serial port out-of-band support with modem control
  • RAID Levels 0, 1, 1+0, 3, 5, 3+0, 5+0
  • Rolling firmware upgrades (with redundant RAID controllers)
  • Up to 128 LUNs
  • SNMP traps and MIB in firmware
  • 512 MB cache memory standard
  • Four Ultra160 SCSI channels
  • User-configurable as drive or host
  • Support for Sun StorEdge Configuration Service and Sun StorEdge Diagnostic Reporter management software and the Sun StorEdge Command-Line Interface (CLI) utility


A.3 Agency Approvals and Standards

TABLE A-3 Agency Approvals and Standards

Product Safety

Country

Standard

U.S.

UL Listed to UL60950:2000, 3rd Edition

Canada

CSA Standard CAN/CSA-C22.2 No. 60950-00 3rd Edition

Germany

TÜV

European Union

EN 60950:2000

Japan

Part of World-wide CB Scheme

Australia

Part of World-wide CB Scheme

Argentina

Resolution 92-98 (S-Mark)

Germany

GS mark (ergonomics) (Rheinland)

Russia

Part of World-wide CB Scheme (GOST-R mark)

Russia

Hygienic Mark (ergonomics)

Electromagnetic Compatibility

Country

Standard

U.S.

FCC #47, Part 15, Subpart B, Class B

Canada

ICES-003

Japan

VCCI Class B

European Union

EN 55022:1998 Class B

Australia/New Zealand

AS/NZS 3548:1996

Taiwan

BSMI CNS 13438 Class B

Russia

GOST-R mark

Germany

Same as European Union

Argentina

S mark

Electromagnetic Interference

Test

Standard

Harmonics Emissions

EN 61000-3-2:2000 (No Limits)

Voltage Flicker

EN 61000-3-3:1995/A1:2001 (No Limits)

ESD

EN 55024 (8kV Contact, 15kV Air)

RF Field

EN 55024 (10V/m)

Electrical Fast Transient Burst

EN 55024 (1kV I/O, 2kV Power)

Surge

EN 55024 (1kV I/O, 1kV Power L-L, 2kV Power L-G)

RF Conducted

EN 55024 (3V I/O and Power)

Power Frequency Magnetic Field

EN 55024 (N/A monitors only)

Voltage Dip and Interruption

EN 55024 (0V/0.5cycle, 70%V/0.5sec, 0V/5sec)