C H A P T E R  1

Sun StorEdge 3000 Family FRUs

This document provides instructions for removing and installing field-replaceable units (FRUs) in Sun StorEdgetrademark 3120 SCSI arrays, Sun StorEdge 3310 SCSI arrays, and Sun StorEdge 3510 FC arrays.

Instructions are also included for FRUs which are common to all three arrays. These FRU components can be replaced by customers or by Sun service representatives.

This chapter covers the following topics:

Removal and installation instructions are provided for the following FRUs:


1.1 Available FRUs

Most FRUs are hot-swappable except a few modules which are hot-serviceable. Hot-serviceable means that the module can be replaced while the RAID product and hosts are powered up but the connected hosts must be inactive.



caution icon

Caution - Please follow the FRU procedures carefully to ensure successful FRU replacement.



The following tables list the FRUs that are currently available. For additional FRUs and X-options, consult your sales representative or the latest Release Notes for Sun StorEdge 3000 Family products on Sun web sites.

TABLE 1-1 List of Available FRUs for the Sun StorEdge 3120 SCSI Array

FRU Model Number

Description

F370-6195-xx

1U JBOD, LVD, Chassis + I/O board with SAF-TE

F370-6193-xx

AC power supply and fan module, 1U

F370-6192-xx

DC power supply and fan module, 1U

F370-5405-xx

Cable, LVD, 1-foot, jumper

F370-5528-xx

Cable, LVD, 1.5-foot, expansion

F540-6054-xx

Drive module, 36 GB LVD, 10K RPM

F540-6055-xx

Drive module, 36 GB LVD, 15K RPM

F540-6056-xx

Drive module, 73 GB LVD, 10K RPM

F540-6057-xx

Drive module, 73 GB LVD, 15K RPM

F540-6058-xx

Drive module, 146 GB LVD, 10K RPM

XTA-3000-AMBS

Air management blank sled




caution icon

Caution - You can mix capacity in the same chassis, but not spindle speed (RPMs) on the same SCSI bus. For instance, you can use 36 Gbyte and 73 Gbyte drives with no performance problems if both are 10K RPM drives. Violating this configuration guideline leads to poor performance.



TABLE 1-2 List of Available FRUs for the Sun StorEdge 3310 SCSI Array

FRU Model Number

Description

F370-5394-xx

Event monitoring unit

F370-5396-xx

I/O module, LVD, expansion unit or JBOD

F370-5397-xx

I/O module, LVD, RAID

F370-5403-xx

Controller module, 512 memory, battery, 2U LVD

F370-5399-xx

Terminator module

F540-5522-xx

Drive module, 36GB LVD, 10K RPM

F540-5563-xx

Drive module, 73GB LVD, 10K RPM

F370-5398xxAC

AC power and fan module, 2U

F370-5527-xxDC

DC power and fan module, 2U

F370-5533-xx

Battery, LVD

F370-5405-xx

Cable, LVD, 1-foot, jumper

F370-5528-xx

Cable, LVD, 1.5-foot, expansion

F370-5393-xx

Box, 2U, JBOD, LVD

F370-5524-xx

Box, 2U, RAID, LVD

XTA-3310-DC-KIT

Power and fan module, 2U, DC


TABLE 1-3 List of Available FRUs for the Sun StorEdge 3510 FC Array

FRU Model Number

Description

F370-5535-xx

Box, 2U, FC, Chassis + Backplane (RAID/JBOD)

F370-5545-xx

Battery, FC, 2U

F370-5540-xx

Cable, FC, 1.5 FT, expansion

F370-5537-xx

I/O w/SES and RAID Controller FC, 1GB memory, battery, 2U

F370-5538-xx

I/O w/SES, JBOD FC, 2U

F370-5398-xx

AC power supply/fan module, 2U

XTA-3310-DC-Kit

DC power supply/fan module, 2U

XTA-3510-36GB-15K

Drive module, 36GB FC, 15KRPM

XTA-3510-73GB-10K

Drive module, 73GB FC, 10KRPM

XTA-3510-146GB-10K

Drive module, 146GB FC, 10KRPM

XTA-3000-AMBS

Air Management Sled

XSFP-SW-2GB

SFP, 2G, SW 850NM, FC, TRANS

XSFP-LW-2GB

SFP, 2G, LW 1310NM, FC, TRANS



1.2 Static Electricity Precautions