Skip Navigation Links | |
Exit Print View | |
![]() |
Sun Storage 6 Gb SAS ExpressModule HBA Installation Guide For HBA Models SGX-SAS6-EM-Z and SG-SAS6-EM-Z |
Chapter 2 Hardware Installation and Removal
Chapter 3 Creating a Bootable Drive in a Preboot Environment
Chapter 4 HBA Software Installation
MegaRAID Storage Manager GUI-Related Issues
Cannot Hotplug the HBA Card Through the MSM GUI
Cannot Assign a Global Hot Spare Through the MSM GUI
Cannot Upgrade Firmware on the HBA Through the MSM GUI
Only 24 Devices Are Displayed In The System BIOS Boot List
Kernel Panic During Oracle Solaris Operating System Installation
The Oracle Solaris OS Installation Hangs
Bug 15637402
Issue: The MegaRAID Storage Manager (MSM) software provides a feature for upgrading firmware on the HBA. If you attempt to upgrade the HBA firmware using this MSM feature, the OS might not boot if the boot disk is installed on a drive that is connected to the newly upgraded HBA.
Workaround: Reboot the system two times after the firmware upgrade. For future upgrades, do not use the MSM software. Instead, upgrade the HBA firmware through the SAS2IRCU utility. You can obtain the SAS2IRCU utility from the Oracle support area of the LSI web site: