System Posts CPU Fault and Fails to Boot on System With Six Sun InfiniBand Dual Port 4x QDR PCIe Low Profile Host Channel Adapter M2 Cards (22536804)

A system equipped with six Sun InfiniBand Dual Port 4x QDR PCIe Low Profile Host Channel Adapter M2 Cards might post CPU faults and fail to boot.


Note -  The Sun Server X2-8 supports a maximum of six Sun InfiniBand Dual Port 4x QDR PCIe Low Profile Host Channel Adapter M2 Cards.

Workaround

  1. Access the BIOS Setup Utility.

  2. Navigate to RC Settings > QPI and change:

    MMIOH Size per IOH from 2Gb to 4Gb (the default is 2Gb).

  3. Navigate to RC Settings > Chipset > NorthBridge Configuration and change:

    PCIE-MMIO-64 Bits Support to Enabled (the default is Disabled).

  4. Save your changes and exit the BIOS Setup Utility.

  5. Reboot the server.