Sun Server X2-8 Service Manual Overview
Controlling Server Power Remotely
Removing and Installing Components
Preparing for Service and Operation
Removal and Installation Procedures
Removing and Installing a Power Supply (CRU)
Removing and Installing a Hard Drive (CRU)
Removing and Installing a Hard Drive Filler
Replacing the Hard Drive Backplane (FRU)
Adding, Removing, and Installing a CMOD (CRU)
CPU Module (CMOD) Designation and Population Rules
Removing and Installing a CMOD Filler
How to Replace the CMOD Battery (CRU)
Removing and Installing DIMMs (CRU)
Removing and Installing a RAID Expansion Module (CRU)
Removing and Installing a Fabric Expansion Module (CRU)
Replacing a CPU and Heatsink Assembly (FRU)
Removing and Installing a Fan Module (CRU)
Replacing a Fan Module Controller Board (FRU)
Removing and Installing a NEM or a NEM Filler (CRU)
Removing and Installing a PCIe EM (CRU)
Preparing a PCIe EM for Hot Plug Removal and Installation
Prepare a PCIe EM for Hot Plug in Oracle Solaris 10 and Solaris 11
How to Install a PCIe EM or PCIe EM Filler
Removing and Installing the Service Processor Module (CRU)
Removing and Installing the Multiport Cable
Removing and Installing the Subassembly Module (FRU)
Sun Server X2-8 Service Procedures and Information
Firmware Information and Procedures
How to Access the BIOS Setup Utility
Component LED Locations and Functions
Sun Server X2-8 Specifications
How to Request Physical Media Online
Note - The PCIe EMs shown in this topic might be different from those supplied with your server.
The PCIe EM slots are designated starting from the bottom as, EM 0.0–EM 3.1:
PCIe EM slots are paired and allocated to a single CMOD. The slots-to-CMOD pairing is as follows:
Slots EM 0.0 and 0.1 are paired to CMOD 0 (BL 0).
Slots EM 1.0 and 1.1 are paired to CMOD 1 (BL 1).
Slots EM 2.0 and 2.1 are paired to CMOD 2 (BL 2).
Slots EM 3.0 and 3.1 are paired to CMOD 3 (BL 3).
For slot number referencing, the PCIe EM slots are numbered as such:
PCIe EM population order for a minimum configuration 4-socket server and a full configuration 8-socket server:
4-socket servers:
Slot 3.0 (IOH 0 on CMOD 3/BL 3)
Slot 0.0 (IOH 0 on CMOD 0/BL 0)—Shared if REM (x4) is present
Slot 3.1 (IOH 1 on CMOD 3/BL 3)
Slot 0.1 (IOH 1 on CMOD 0/BL 0)
8-socket servers:
Slot 3.0 (IOH 1 on CMOD 3/BL 3)
Slot 1.0 (IOH 2 on CMOD 1/BL 1)
Slot 0.0 (IOH 0 on CMOD 0/BL 0)—Shared if REM (x4) is present
Slot 2.0 (IOH 3 on CMOD 2/BL 2)
Slot 3.1 (IOH 1 on CMOD 3/BL 3)
Slot 1.1 (IOH 2 on CMOD 1/BL 1)
Slot 0.1 (IOH 0 on CMOD 0/BL 0)
Slot 2.1 (IOH 3 on CMOD 2/BL 2)
Note - For proper airflow and cooling slots not containing a PCIe EM must be populated with a filler panel.