Hardware and Networking Issues
sxge Device Corresponding to Port 1 Cannot Communicate with External Hosts in 40G or 1G Mode
CMM Minimum Version and CMM ILOM Upgrade Requirement (7046303)
Cannot Unload sxge When Interfaces are Unplumbed (7045733)
Hot Plug is Not Supported by VMware
PCI Correctable Errors Might Occur When Using NEM (7012350 and 7064505)
Hot Plug is Not Supported by Windows 2008 R2 with Sun Blade X6270 M2 and NEM (7050066)
Sometimes sxge Ports Fail to Enumerate During Hot-plug with Sun Blade X6270 M2 Blades (7087921)
ILOM Web GUI Reports Error: “Command Failed” (16092938)
Highest Lane Number in show peu Output is Incorrect (7039713)
Unable to Access NEM by Clicking on Graphic from the CMM ILOM Web GUI (7099903)
Two indications occur when the NEM is detected properly.
When the pcitool -v command is run, output similar to the following is reported:
# pcitool -v | grep 207 Device ID: 2070 Device ID: 2070 Device ID: 2070 Device ID: 2078 Device ID: 2078
If the driver is installed, you can successfully plumb the interface without any error messages, as in the following example
bash-3.00# ifconfig sxge0 plumb up bash-3.00# bash-3.00# ifconfig -a lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1 inet 127.0.0.1 netmask ff000000 igb0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 2 inet 10.134.167.26 netmask ffffff00 broadcast 10.134.167.255 ether 0:21:28:bc:7:ac sxge0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 9 inet 0.0.0.0 netmask ff000000 ether 0:21:28:c6:ff:c6
If none of these indications is shown, then the issue is present on the blades.