JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Oracle Integrated Lights Out Manager (ILOM) 3.1 Documentation Collection
search filter icon
search icon

Document Information

Using This Documentation

Related Documentation

Documentation Feedback

Product Downloads

Download Product Software and Firmware

Oracle ILOM 3.1 Firmware Version Numbering Scheme

Support and Accessibility

Quick Start

Oracle ILOM 3.1 – Quick Start

Factory Default Settings

Mandatory Setup Tasks

Optional Setup Tasks

Daily Management Tasks

Routine Maintenance Tasks

Initial Setup FAQs

Configuration and Maintenance

Setting Up a Management Connection to Oracle ILOM and Logging In

Establishing a Management Connection to Oracle ILOM

Logging In to Oracle ILOM Server SP or CMM

Configuring Oracle ILOM for Maximum Security

Setting Up and Maintaining User Accounts

Managing User Credentials

Configuring Local User Accounts

Configuring Active Directory

Configuring LDAP/SSL

Configuring LDAP

Configuring RADIUS

Modifying Default Settings for Network Deployment and Administration

Network Deployment Principles and Considerations

Modifying Default Management Access Configuration Properties

Modifying Default Connectivity Configuration Properties

Example Setup of Dynamic DNS

Assigning System Identification Information

Setting Properties for SP or CMM Clock

Suggested Resolutions for Network Connectivity Issues

Using Remote KVMS Consoles for Host Server Redirection

First-Time Setup for Oracle ILOM Remote Console

Launching and Using the Oracle ILOM Remote Console

First Time Setup for Oracle ILOM Storage Redirection CLI

Launching and Using the Oracle ILOM Storage Redirection CLI

Starting and Stopping a Host Serial Redirection Session

Host Serial Console Log Properties

Configuring Host Server Management Actions

Controlling Host Power to Server or Blade System Chassis

Setting Host Diagnostic Tests to Run

Setting Next Boot Device on x86 Host Server

Setting Boot Behavior on SPARC Host Server

Overriding SPARC Host Boot Mode

Managing SPARC Host Domains

Setting SPARC Host KeySwitch State

Setting SPARC Host TPM State

Setting Up Alert Notifications and Syslog Server for Event Logging

Configuring Alert Notifications

Configuring Syslog for Event Logging

Setting System Management Power Source Policies

Power-On and Cooling-Down Policies Configurable From the Server SP

System Management Power Supply Policies Configurable From CMM

Setting Power Alert Notifications and Managing System Power Usage

Setting Power Consumption Alert Notifications

Setting CMM Power Grant and SP Power Limit Properties

Setting SP Advanced Power Capping Policy to Enforce Power Limit

Setting SP Power Management Settings for Power Policy (SPARC)

Setting the CMM Power Supply Redundancy Policy

Performing Oracle ILOM Maintenance and Configuration Management Tasks

Performing Firmware Updates

Reset Power to Service Processor or Chassis Monitoring Module

Backing Up, Restoring, or Resetting the Oracle ILOM Configuration

Maintaining x86 BIOS Configuration Parameters

BIOS Configuration Management

Performing BIOS Configuration Tasks From Oracle ILOM

SAS Zoning Chassis Blade Storage Resources

Zone Management for Chassis-Level SAS-2 Capable Resources

Manageable SAS-2 Zoning-Capable Devices

Sun Blade Zone Manager Properties

Important SAS Zoning Allocations Considerations

Enabling Zoning and Creating SAS-2 Zoning Assignments

Managing Existing SAS-2 Storage Resource Allocations

Resetting Sun Blade Zone Manager Allocations to Factory Defaults

Resetting the Zoning Password to Factory Default for Third-Party In-Band Management

User's Guide

Oracle ILOM Overview

About Oracle ILOM

Oracle ILOM Features and Functionality

Supported Management Interfaces

Supported Operating System Web Browsers

Integration With Other Management Tools

Getting Started With Oracle ILOM 3.1

Logging In to Oracle ILOM

Navigating the Redesigned 3.1 Web Interface

Navigating the Command-Line Interface (CLI) Namespace Targets

Collecting System Information, Monitoring Health Status, and Initiating Host Management

Collecting Information, Status, and Initiating Common Actions

Administering Open Problems

Administering Service Actions: Oracle Blade Chassis NEMs

Managing Oracle ILOM Log Entries

Performing Commonly Used Host Management Actions (Web)

Applying Host and System Management Actions

Administering Host Management Configuration Actions

Administering System Management Configuration Actions

Troubleshooting Oracle ILOM Managed Devices

Network Connection Issues: Oracle ILOM Interfaces

Tools for Observing and Debugging System Behavior

Enabling and Running Oracle ILOM Diagnostic Tools

Real-Time Power Monitoring Through Oracle ILOM Interfaces

Monitoring Power Consumption

Monitoring Power Allocations

Analyzing Power Usage Statistics

Comparing Power History Performance

Managing Oracle Hardware Faults Through the Oracle ILOM Fault Management Shell

Protecting Against Hardware Faults: Oracle ILOM Fault Manager

Oracle ILOM Fault Management Shell

Using fmadm to Administer Active Oracle Hardware Faults

Using fmdump to View Historical Fault Management Logs

Using fmstat to View the Fault Management Statistics Report

Using the Command-Line Interface

About the Command-Line Interface (CLI)

CLI Reference For Supported DMTF Syntax, Command Verbs, Options

CLI Reference For Executing Commands to Change Properties

CLI Reference For Mapping Management Tasks to CLI Targets

CLI Reference

Basic CLI Command Reference for Oracle ILOM 3.1

System Information and Management

Host and System Control

Oracle ILOM Initial Setup

System Monitoring and Status

System Inventory

Oracle ILOM Maintenance

Oracle ILOM Configuration Management

Oracle ILOM Help

SNMP, IPMI, CIM, WS-MAN Protocol Management

SNMP Overview

About Simple Network Management Protocol

SNMP Components

Oracle ILOM SNMP MIBs

SNMP Command-Line Syntax Examples

Configuring SNMP Settings in Oracle ILOM

Managing SNMP Read and Write Access, User Accounts, and SNMP Trap Alerts (CLI)

Managing SNMP Read and Write Access, User Accounts, and SNMP Trap Alerts (Web)

Downloading SNMP MIBs Using Oracle ILOM

Manage User Accounts Using SNMP

Before You Begin – User Accounts (SNMP)

Configuring Oracle ILOM User Accounts (SNMP)

Configuring Oracle ILOM for Active Directory (SNMP)

Manage DNS Name Server Settings (SNMP)

Configuring Oracle ILOM for LDAP (SNMP)

Configuring Oracle ILOM for LDAP/SSL (SNMP)

Configuring Oracle ILOM for RADIUS (SNMP)

Manage Component Information and Email Alerts (SNMP)

Before You Begin – Component Information (SNMP)

Viewing Component Information (SNMP)

Managing Clock Settings, Event Log, Syslog Receiver, and Alert Rules (SNMP)

Configuring SMTP Client for Email Alert Notifications (SNMP)

Configuring Email Alert Settings (SNMP)

Monitor and Manage System Power (SNMP)

Before You Begin – Power Management (SNMP)

Monitoring the Power Consumption Interfaces (SNMP)

Maintaining System Power Policy (SNMP)

Managing System Power Properties (SNMP)

Manage Oracle ILOM Firmware Updates (SNMP)

Update Oracle ILOM Firmware (SNMP)

Manage Oracle ILOM Backup and Restore Configurations (SNMP)

View and Configure Backup and Restore Properties (SNMP)

Manage SPARC Diagnostics, POST, and Boot Mode Operations (SNMP)

Before You Begin – Manage SPARC Hosts (SNMP)

Managing SPARC Diagnostic, POST, and Boot Mode Properties (SNMP)

Server Managment Using IPMI

Intelligent Platform Management Interface (IPMI)

About IPMI

IPMItool

IPMI Alerts

IPMI Administrator and Operator Roles

Configuring the IPMI Service

Enable IPMI Service State (CLI)

Enable IPMI Service State (Web)

Using IPMItool to Run ILOM CLI Commands

Before You Begin – IPMItool and Oracle ILOM Requirements

Access the Oracle ILOM CLI From IPMItool

Scripting Oracle ILOM CLI Commands With IPMItool

Performing System Management Tasks (IPMItool)

Before You Begin - Oracle ILOM and IPMItool Requirements

Display Sensor List

View Single Sensor Details

View and Interpret Presence Sensor Type Values

Manage Host Power-On, Power-Off and Shutdown Functions

Manage Oracle ILOM Power Budget Interfaces

Manage the System Power Policy

Display FRU Manufacturing Details

Display the Oracle ILOM Event Log

IPMItool Utility and Command Summary

Server Management Using WS-Management and CIM

WS-Management and CIM Overview

Configuring Support for WS-Management in Oracle ILOM

Supported DMTF SMASH Profiles, CIM Classes and CIM Indications

Oracle's Sun-Supported CIM Classes

Document Conventions for Oracle's Sun-Supported CIM Classes

Oracle_AssociatedIndicatorLED

Oracle_AssociatedSensor

Oracle_Chassis

Oracle_ComputerSystem

Oracle_ComputerSystemPackage

Oracle_Container

Oracle_ElementCapabilities

Oracle_ElementConformsToProfile

Oracle_EnabledLogicalElementCapabilities

Oracle_HWCompErrorOkIndication

Oracle_IndicatorLED

Oracle_InstCreation

Oracle_InstDeletion

Oracle_LogEntry

Oracle_LogManagesRecord

Oracle_Memory

Oracle_NumericSensor

Oracle_PhysicalAssetCapabilities

Oracle_PhysicalComponent

Oracle_PhysicalElementCapabilities

Oracle_PhysicalMemory

Oracle_PhysicalPackage

Oracle_Processor

Oracle_ProcessorChip

Oracle_Realizes

Oracle_RegisteredProfile

Oracle_RecordLog

Oracle_ReferencedProfile

Oracle_Sensor

Oracle_SpSystemComponent

Oracle_SystemDevice

Oracle_ThresholdIndication

Oracle_UseOfLog

SNMP Command Examples

snmpget Command

snmpwalk Command

snmpbulkwalk Command

snmptable Command

snmpset Command

snmptrapd Command

Feature Updates and Release Notes

Feature Enhancements as of Oracle ILOM 3.1

Feature Enhancements Summary

Updates to Oracle ILOM 3.1.x Firmware

Initial 3.1 Point Releases for Servers and Sun Blade 6000 CMM

Deprecation Notice for WS-Man as of Oracle ILOM 3.2.1

Oracle ILOM 3.1 Known Issues

Documentation Titles in Translated Documents

Glossary

Index

Manage Oracle ILOM Power Budget Interfaces

  1. To set the Power Limit Activation State on a managed device, use one of the following commands:
    • To activate:

      $ ipmitool -H SP_hostname_or_IPaddress -U username -P password raw 0x2e 0x49 0x00 0x01 0xFF 0xFF

      Upon command completion:

      dc

    • To deactivate:

      $ ipmitool -H SP_hostname_or_IPaddress -U username -P password raw 0x2e 0x49 0x00 0x00 0xFF 0xFF

      Upon command completion:

      dc

    The following table describes the Power Limit Activation State (IPMItool) input and output fields:


    Fields
    Byte
    Description
    Input Data

    1
    Sun OEM command group number: 0x2e.
    2
    Command code 0x49 sets the power limit activation state.
    3
    Group extension identification: 0x00. The value for this field is ignored.
    4
    Sub-commands for power-limit activation:

    0x00 - Deactivate power limit

    0x01 - Activate power limit

    5-6
    Reserved fields: 0xFF. The values for this field are ignored.
    Output Data

    1
    Completion code consumed by IPMItool.

    The system does not display a status for successful completion code. However, if the result of the completion code is anything other than 'successful', a failure message appears.

    2
    Group extension identification ‘dc' appears upon command completion.
  2. To get Power Limit budget properties, type:

    Note - You should use a Get Power Limit Budget Wattage command prior to setting the power-limit budget wattage property.


    $ ipmitool -H SP_hostname_or_IPaddress -U username -P password raw 0x2e 0x4A 0x00 0x00 0x00

    Upon command completion:

    dc 00 01 b3 00 02 fa 00 00 00 00 01 e9 00 00

    The following table describes the Get Power Limit (IPMItool) input and output fields:


    Field
    Byte
    Description
    Input Data

    1
    Sun OEM command group number: 0x2e.
    2
    Command code 0x4A gets Power Budget settings.
    3
    Group extension identification: 0x00. The value for this field is ignored.
    4-5
    Reserved fields: 0x00. Values for this field are ignored.
    Output Data

    1
    Completion code, consumed by IPMItool. Not displayed upon command completion.However if completion code is anything other than success, then a failure message isdisplayed upon command completion.
    2
    Group extension identification. Displayed as 'dc‘ in the preceding example.
    3
    Activation state:

    00 - deactivated

    01 - activated

    4
    Reserved field. Note that the value b3 in the preceding example can be ignored.
    5
    Exception action, taken if power limit is exceeded and cannot be controlled within the correction time limit. Return values:

    00 - none

    01 - hard power-off

    6-7
    Power limit in watts. 02 fa in the preceding example.
    8-11
    Correction timelimit in milliseconds. 00 00 00 00 in the preceding example.
    12
    Flag indicating whether the correction time limit is the system default timelimit.

    00 - not default

    01 - default

    13
    Reserved field. Note that the value shown (e9) in the preceding example can be ignored.
    14-15
    Reserved fields. Note that the value shown (00 00) in the preceding example can be ignored.
  3. To set the Power Limit, type:

    Note - The set power limit commands sets the power budget limit for the system. Use this command to set the maximum system power usage. The power limit should always be persistent across AC and DC cycles.


    $ ipmitool -H SP_hostname_or_IPaddress -U username -P password raw 0x2e 0x4B 0x00 0xff 0xff 0xff 0x01 0x02 0xaa 0x00 0x00 0x1b 0x58 0x00 0xff 0x00 0x00

    Upon command completion:

    dc 00

    The following table describes Set Power Limit (IPMItool) input and output fields:


    Fields
    Byte
    Description
    Input Data

    1
    Sun OEM command group number: 0x2e.
    2
    Command code 0x4B sets power budget settings.
    3
    Group extension identification: 0x00. The value for this field is ignored.
    4-6
    Reserved fields: 0xff 0xff 0xff. The values for this field are ignored.
    7
    Exception action taken: 00 - none 01 - hard power-off
    8-9
    Power limit in watts. For example: 0x2a 0xaa

    10-13
    Correction time limit in milliseconds. For example: 0x00 0x00 0x1b 0x58. This value is ignored if the time limit is set to default; see next byte.
    14
    A flag indicating whether to use the system default time limit. Correction time limit in bytes 10-13 will be ignored. 0x00 - not default 0x01 - default
    15
    Reserved field: 0xff. The value for this field is ignored.
    16-17
    Reserved field: 0x00 0x00. The value for this field is ignored.
    Output Data

    1
    Completion code that is consumed by IPMItool.

    The system does not display a status for successful completion code. However, if the result of the completion code is anything other than successful, a failure message appears.

    2
    Group extension identification 'dc' appears upon command completion.