Disable Debug UARTS on LSI 2308 Controllers (16802420)

On rare occasions, these warning messages might be displayed on the host console:

WARNING: /pci@300/pci@1/pci@0/pci@4/scsi@0 (mpt_sas0):
Disconnected command timeout for Target 9
WARNING: mptsas_ioc_task_management failed try to reset ioc to
recovery!
WARNING: Target 9 reset for command timeout recovery failed!

The warning messages indicate that the SAS controller (mpt_sas), which is used to access the internal hard and solid state devices, had trouble communicating. As a result, the SAS controller is reset and the I/O command is reissued.

In most cases, the SAS controller successfully reconnects, and the I/O command completes as normal, as indicated by these messages:

mptsas0 Firmware version v14.0.0.0 (?)
mptsas0: IOC Operational.

Fix: Update the SAS controller firmware:


Note -  Perform these steps only if your server experiences the SAS disconnect timeout issue.
  1. Obtain the SAS controller patch for this server.

    SPARC T5-8 server SAS patch ID: 16801179

    See Obtain Patches.

  2. Follow the instructions in the patch README file.


    Note -  To update the SAS controller firmware, you must first obtain and install the Oracle Hardware Management Pack (HMP) software. Instructions in the README file describe how to obtain and install HMP.