CMDTUX メッセージ 700-799
700
ERROR:Group's current location inconsistent with TUXCONFIG file
ERROR: グループの現在位置が TUXCONFIG ファイルと一致しません。
説明
The location of a server group was being updated in the master copy of the TUXCONFIG
file, to reflect a new location after migration. The new location unexpectedly did not match either the primary or backup specified in the TUXCONFIG
file.
アクション
The master machine's TUXCONFIG
is inconsistent with the group's real location. The file can be restored by shutting down the application, and then running tmloadcf
using a backup ASCII version of the configuration file. Running tmunloadcf
on another machine in the configuration should provide a recent backup version.
関連項目
tmloadcf
(1), tmunloadcf
(1), ubbconfig
(5)
730
ERROR: Memory allocation failure
説明
分断された lmid とその関連サーバをシャットダウンする際、このエラーが発生しました。
アクション
Remove processes that may be tying up physical memory, ensure that the application ipckey
is correct, or verify that the UNIX sysgen
process sizing parameters are correct.
関連項目
tmshutdown
(1)
731
ERROR:for debug level
ERROR: デバッグ・レベル
説明
A non-numeric argument was specified with the debugging option of tmboot
or tmshutdown
, causing the process to abort.
アクション
デバッグ・レベル・コマンド行オプションに数値を指定します。
732
ERROR:for srvid
ERROR: srvid
説明
The argument for the -i
option of tmboot
or tmshutdown
is not a numeric value between 1 and 30,000.
アクション
1 - 30,000 の数値を指定します。
関連項目
tmboot
(1)、tmshutdown
(1)、ubbconfig
(5)
733
ERROR:for sequence number
ERROR: シーケンス番号
説明
The argument for the -o
option of tmboot
or tmshutdown
is not a numeric value between 1 and 9,999.
アクション
1 - 9,999 の数値を指定します。
関連項目
tmboot
(1)、tmshutdown
(1)、ubbconfig
(5)
734
ERROR:for delay
ERROR: 遅延
説明
The argument for the -w
option of tmshutdown
is not a number greater than 0.
アクション
0 より大きな数値を指定します。
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1), ubbconfig
(5)
735
ERROR: Memory allocation failure
説明
This error occurred while booting the MASTER
machine.
アクション
Remove processes that may be tying up physical memory, ensure that the application ipckey
is correct, or verify that the UNIX sysgen
process sizing parameters are correct.
関連項目
tmboot
(1)
737
ERROR:tmboot too many arguments
ERROR: tmboot 引数が多すぎます。
説明
An argument is present that does not match the options selected for tmboot
, or no options are specified and an argument is passed.
アクション
コマンド行のオプションを確認してから再発行します。
関連項目
BEA TUXEDO Administrator's Guide, tmboot
(1)
738
ERROR:-R option requires either the -g or -l option
ERROR: -R オプションには -g か -l オプションが必要です。
説明
A shutdown request with the -R
option shuts down servers on their original processors to prepare them for migration to another processor. This option must be used with either the group name, -g
grpname, or logical name, -l
lmid, option.
アクション
Resubmit the command and specify either the -g
or -l
option that contains the servers to be shut down and eventually migrated.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
739
ERROR:-A option not allowed with -R
ERROR: -R は -A と共には指定できません。
説明
A shutdown request with the migration option, -R
, has been issued with the administrative servers option, -A
. This request isn't valid, since migration is specific to server groups through options -l
or -g
, not administrative servers.
アクション
Resubmit tmshutdown
with either option -R
to shut down the servers specified for migration, or after all the servers in the SERVERS section of the configuration file have been shut down, the -A
option may be used to shut down the administrative servers.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
740
ERROR:-S option not allowed with -R
ERROR: -R は -S と共には指定できません。
説明
A shutdown request with the -R
option has been issued with the -S
option specifying that all servers in the SERVERS section of the configuration file should be shut down for migration. This request isn't valid since the -R
option must be used with either option -l
or -g
.
アクション
Resubmit tmshutdown
without the -S
option and instead specify the servers to be shut down by the -l
lmid or -g
grpname options that contain these server groups.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
741
ERROR:-B option not allowed with -R
ERROR: -B オプションは -R と共には指定できません。
説明
A shutdown request with the migration, -R
, option has been issued with the BBL, -B
, option. A BBL
may not be shut down for migration.
アクション
Resubmit tmshutdown
without the -B
option and instead specify the servers to be shut down by the -l
lmid or -g
grpname options that contain these server groups.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
742
ERROR:-T option not allowed with -R
ERROR: -T オプションは -R と共には指定できません。
説明
A shutdown request with the migration, -R
, option has been issued with the TMS
servers, -T
, option. A TMS
may not be shut down for migration.
アクション
Resubmit tmshutdown
without the -T
option and instead specify the servers to be shut down by the -l
lmid or -g
grpname options that contain these server groups.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
743
ERROR:-H option not allowed with -R
ERROR: -H オプションは -R と共には指定できません。
説明
A shutdown request with the migration, -R
, option has been issued with the -H
option to shut down all administrative and application servers on a specified processor. This request isn't valid since migration is specific to server groups through options -l
or -g
, not administrative servers.
アクション
Resubmit tmshutdown
with the -l
option to specify the servers to be shut down on the specified processor for migration.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
744
ERROR:-i option not allowed with -R
ERROR: -i オプションは -R と共には指定できません。
説明
A shutdown request with the migration, -R
, option has been issued with the -i
srvid option which will shut down all servers in the SERVERS section of the configuration file whose SRVID
parameter is srvid. This request isn't valid since the -R
option must be used with either option -l
or -g
.
アクション
Resubmit tmshutdown
without the -i
option and instead specify the servers to be shut down by the -l
lmid or -g
grpname options that contain these server groups.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
745
ERROR:-o option not allowed with -R
ERROR: -o オプションは -R と共には指定できません。
説明
A shutdown request with the migration, -R
, option has been issued with the -o
sequence option which will shut down all servers in the SERVERS section of the configuration file whose SEQUENCE
parameter is sequence. This request isn't valid since the -R
option must be used with either option -l
or -g
.
アクション
Resubmit tmshutdown
without the -o
option and instead specify the servers to be shut down by the -l
lmid or -g
grpname options that contain these server groups.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
746
ERROR:-s option not allowed with -R
ERROR: -s オプションは -R と共には指定できません。
説明
A shutdown request with the migration, -R
, option has been issued with the -s
aout option which will shut down all servers in the SERVERS section of the configuration file whose name is aout. This request isn't valid since the -R
option must be used with either option -l
or -g
.
アクション
Resubmit tmshutdown
without the -s
option and instead specify the servers to be shut down by the -l
lmid or -g
grpname options that contain these server groups.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
754
ERROR:error processing configuration file
ERROR: コンフィギュレーション・ファイルの処理中にエラーがありました。
説明
When booting or shutting down an application, tmboot
or tmshutdown
attempts to load in the TUXCONFIG
file. At this point the configuration file defined by the environment variable TUXCONFIG
cannot be found or has been corrupted.
アクション
The value of the TUXCONFIG
environment variable should be checked to see if it set to the correct configuration file and exported. After ensuring that this variable is set correctly and the same failure occurs, the TUXCONFIG
file has been corrupted. The TUXCONFIG
file must be regenerated by the tmloadcf
command from the UBBCONFIG
file.
関連項目
tmboot
(1), tmloadcf
(1), tmshutdown
(1), ubbconfig
(5)
755
ERROR:-R option not allowed if MIGRATE not specified
ERROR: MIGRATE を宣言していない場合は -R オプションを指定できません。
説明
A shutdown request with the -R
option has been issued for a configuration that does not have the MIGRATE
option specified in the UBBCONFIG
file.
アクション
To enable migration for an application in this situation, the application must be shut down, and the configuration must be updated to include the MIGRATE
option (in the RESOURCES section). Then the TUXCONFIG
file must be recompiled using tmloadcf
, and after the application is brought back up, migration may be performed.
関連項目
BEA TUXEDO Administrator's Guide, tmboot
(1), tmloadcf
(1), tmshutdown
(1), ubbconfig
(5)
756
ERROR:-P option not allowed on non-partitioned node
ERROR: 非分断ノードには -P オプションを指定できません。
説明
A shutdown request with the -P
option has been issued on a non-partitioned node. The -P
option is specifically used for nodes that are partitioned (there is no access with the DBBL).
アクション
To shut down servers on this lmid, the -l
option may be used.
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
757
ERROR:Could not reset model to MP for partitioned shutdown
ERROR: 分断シャットダウンで MP にモデルを再設定できません。
説明
A BEA TUXEDO system internal value was not set correctly. Check the userlog for additional error messages to clarify this error condition. The circumstances associated with this error are not likely to be caused by something that the invoker of the tmshutdown
command will have done. It is more likely to be a BEA TUXEDO system error.
アクション
同じ操作を繰り返します。問題が解消されない場合は、BEA TUXEDO システムの Technical Support にお問い合わせください。
関連項目
tmshutdown
(1)
758
ERROR:Could not attach to local BB for partitioned shutdown
ERROR: 分断シャットダウンでローカルの掲示板にアタッチできません。
説明
While trying to connect to the local bulletin board to complete the partitioned shutdown request, an error occurred in the initialization phase. There are several scenarios that may eventually cause this error, including a corrupted TUXCONFIG
file, authentication failure, and invalid buffer types. Also, the tpinfo buffer could contain illegal values.
アクション
ユーザ・ログでエラー・メッセージを調べ、問題を判別します。問題の原因が不明な場合は、BEA TUXEDO システムの Technical Support にお問い合わせください。
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
759
ERROR:Could not bring up temp DBBL for partitioned shutdown
ERROR: 分断シャットダウンで一時 DBBL を起動できません。
説明
分断シャットダウン要求を処理する場合は、一時 DBBL プロセスを起動する必要があります。このときに、分断されていないマシン上でコマンドを実行したりするとエラーが発生します。あるいは、疑似 DBBL を起動する際に、「分断された」サイトから別のブリッジを通じて元の DBBL にまだアクセスすることができます。
アクション
Determine if the machine is partitioned (by using the tmadmin
command psr
). Check the userlog for error messages to clarify the problem. If the machine is partitioned and this error occurs again, contact your BEA TUXEDO system Technical Support.
関連項目
BEA TUXEDO Administrator's Guide, tmadmin
(1), tmshutdown
(1)
760
ERROR:Failed to attach to temp DBBL for partitioned shutdown
ERROR: 分断シャットダウンで一時 DBBL へのアタッチが異常終了しました。
説明
The tmadmin
process was unable to attach itself to the Bulletin Board to perform the requested action. Check the userlog for additional error messages to clarify the problem.
アクション
コマンドを再実行します。問題が解消されない場合は、BEA TUXEDO システムの Technical Support にお問い合わせください。
関連項目
BEA TUXEDO Administrator's Guide, tmshutdown
(1)
761
ERROR:Illegal TUXCONFIG value
ERROR: 不当な TUXCONFIG の値
説明
The value of the TUXCONFIG
environment variable and the caller process and the value for the machine set in the UBBCONFIG
file are inconsistent.
アクション
Reset the TUXCONFIG
variable and rerun the command.
関連項目
ubbconfig
(5)
762
ERROR:LAN mode not specified for multiple node application
ERROR: LAN モードが複数のノード・アプリケーションに宣言されていません。
説明
The OPTIONS
parameter in the RESOURCES section must specify the LAN
option for a multiple node application.
アクション
Change the application configuration to ensure that the OPTIONS
parameter in the RESOURCES section includes the LAN
value.
関連項目
ubbconfig
(5)
763
ERROR:cannot create internal BB tables
ERROR: 内部掲示板テーブルを作成できません。
説明
起動中に、共用メモリにアタッチしようとしてアプリケーション・エラーが発生しました。
アクション
BEA TUXEDO システムの Technical Support にお問い合わせください。
関連項目
tmboot
(1)
764
ERROR:can't attach to BB
ERROR: 掲示板にアタッチできません。
説明
アプリケーションをシャットダウン中に、コンフィギュレーションの掲示板にアタッチしようとしてエラーが発生しました。
アクション
Check the userlog for additional diagnostic messages. Normally this error implies that the TUXCONFIG
environment variable is not set correctly, or that the application is not booted.
関連項目
tmshutdown
(1)
765
ERROR:must run on master node
ERROR: マスタ・ノードで実行しなければなりません。
説明
tmboot
must be run on either of the master nodes specified in the MASTER
parameter of the RESOURCES section. tmshutdown
must be run on the active master.
アクション
適切な処理要素上で、起動またはシャットダウン・コマンドを再発行します。
関連項目
tmboot
(1)、tmshutdown
(1)
766
ERROR:must run on master node
ERROR: マスタ・ノードで実行しなければなりません。
説明
起動要求は、コンフィギュレーションに指定されたバックアップ・マスタ・ノードから発行されます。そうしないと、シャットダウン要求の際にシステムで DBBL プロセスを見つけられません。
アクション
コンフィギュレーションに指定されたマスタから起動要求を再発行します。このエラーがシャットダウン要求に起因する場合は、要求を再発行する前に DBBL プロセスが動作していることを確認します。
関連項目
tmboot
(1)、tmshutdown
(1)
767
ERROR:must run on master node
ERROR: マスタ・ノードで実行しなければなりません。
説明
シャットダウン要求は、コンフィギュレーションに指定されたマスタ・ノードから発行されます。ところが、元のマスタが移行されたために、このノードがアクティブなマスタでなくなっています。
アクション
アクティブなマスタからシャットダウン要求を再発行します。
関連項目
tmshutdown
(1)
768
ERROR:Bad LMID (lmid) in command line option(s)
ERROR: コマンド行のオプション中に間違った LMID (lmid) があります。
説明
The argument lmid specified for the command line option is invalid.
アクション
Check the configuration for the correct lmid value and reissue the command.
関連項目
tmboot
(1)、tmshutdown
(1)
769
ERROR:Server group name (grpname) too long
ERROR: サーバ・グループ名 (grpname) が長すぎます。
説明
コマンド行オプションに指定されたグループ名が長すぎます。サーバ・グループ名は 30 文字以下でなければなりません。
アクション
コンフィギュレーションで正しいグループ名を調べ、コマンドを再発行します。
関連項目
tmboot
(1)、tmshutdown
(1)、ubbconfig
(5)
770
ERROR:Invalid server group name (grpname)
ERROR: サーバ・グループ名 (grpname) が無効です。
説明
このコマンドに指定されたグループ名はコンフィギュレーションにありません。
アクション
コンフィギュレーションで正しいグループ名を調べ、コマンドを再発行します。
関連項目
tmboot
(1)、tmshutdown
(1)、ubbconfig
(5)
771
ERROR:Bad command line options!Check the LOG file
ERROR: 間違ったコマンド行のオプションです。ログ・ファイルを調べます。
説明
無効なコマンド行オプションが指定されたために、致命的なエラーが発生しました。
アクション
ユーザ・ログ・ファイルを調べ、エラーの原因を特定します。
関連項目
tmboot
(1)、tmshutdown
(1)、ubbconfig
(5)
772
ERROR:can't get (D)BBL's table entry
ERROR: (D)BBL のテーブル・エントリを取得できません。
説明
システムのシャットダウン中に、サーバ・テーブル・エントリが不整合な状態となりました。
アクション
BEA TUXEDO システムの Technical Support にお問い合わせください。
777
INFO:See ULOG for complete process status
INFO: プロセスの終了状態を ULOG で確認してください。
説明
このメッセージは、ユーザ・ログに詳しい情報があることをユーザに通知するものです。
アクション
アクションは必要ありません。
786
ERROR: Memory allocation failure
説明
シャットダウン中に、プロセス情報を保持する内部構造にメモリを割り当てられませんでした。
アクション
Remove processes that may be tying up physical memory, ensure that the application ipckey
is correct, or verify that the UNIX sysgen
process sizing parameters are correct.
787
ERROR: Memory allocation failure
説明
シャットダウン中に、プロセス情報を保持する内部構造にメモリを割り当てられませんでした。
アクション
物理メモリを占有するプロセスを削除し、アプリケーションの IPC キーと UNIX sysgen
のプロセス・サイジング・パラメータが正しいことを確認します。
788
ERROR: Memory allocation failure
説明
シャットダウン中に、プロセス情報を保持する内部構造にメモリを割り当てられませんでした。
アクション
物理メモリを占有するプロセスを削除し、アプリケーションの IPC キーと UNIX sysgen
のプロセス・サイジング・パラメータが正しいことを確認します。
790
INFO: *Interrupt* Want to Continue? (y/n):
INFO: 中断しました。続けますか?(y/n):
説明
アラームがオンの状態でシステムがシャットダウンされました。
アクション
You may proceed with the shutdown request by entering 'y
', or you may abort the request by entering 'n
'.
794
ERROR: Memory allocation failure
説明
During tmboot
, memory could not be allocated for an internal structure that holds process information.
アクション
物理メモリを占有するプロセスを削除し、アプリケーションの IPC キーと UNIX sysgen
のプロセス・サイジング・パラメータが正しいことを確認します。
795
ERROR: Memory allocation failure
説明
During tmboot
, memory could not be allocated for an internal structure that holds process information.
アクション
物理メモリを占有するプロセスを削除し、アプリケーションの IPC キーと UNIX sysgen
のプロセス・サイジング・パラメータが正しいことを確認します。
796
ERROR:Cannot continue booting without DBBL
ERROR: DBBL が無いので起動を続けることができません。
説明
マルチプロセシング・コンフィギュレーションのブート・シーケンスでは、BBL を 起動する前に DBBLプロセスを起動する必要があります。DBBL が起動されていませんでした。
アクション
Make sure that the DBBL is running on the master node. If the DBBL is in fact running, contact your BEA TUXEDO system Technical Support. Otherwise, the DBBL must be booted (unless all of the admin processes are started at the same time with tmboot -A
).
関連項目
tmboot
(1)
797
ERROR:No BBL available for boot of BRIDGE on lmid
ERROR: lmid の BRIDGE の起動に関係する有効な BBL がありません。
説明
The BRIDGE
process requires that a BBL is present on that lmid. The BBL is not currently available.
アクション
The BBL may be booted explicitly using tmboot -B
lmid and the original command retried.
関連項目
tmboot
(1)
798
ERROR:Cannot boot remote BBL(lmid1), no BRIDGE available on DBBLs node(lmid2)
ERROR: リモート BBL (lmid1)を起動できません。DBBL ノード (lmid2) に有効な BRIDGE がありません。
説明
The BRIDGE
process on the DBBL's node, lmid2, must be present to boot the BBL on lmid1 as requested.
アクション
BEA TUXEDO システムの Technical Support にお問い合わせください。
799
ERROR:Cannot boot remote BBL(lmid), machine inaccessible
ERROR: リモート BBL (lmid) を起動できません。マシンにアクセスできません。
説明
The node lmid is inaccessible and the BBL may not be booted as requested.
アクション
Verify that the node lmid is running. If so, contact your BEA TUXEDO system Technical Support.