This appendix lists the replacement units for Oracle Big Data Appliance. All replacement units are field replaceable units (FRUs), which are installed by Oracle field engineers.
This appendix contains the following sections:
Repair categories describe the potential effects of a repair action. Table B-1 describes the categories and related actions.
Table B-1 Oracle Big Data Appliance Repair Categories
Category | Description | Scenario Examples |
---|---|---|
The repair part is hot swappable and can be replaced without shutting down the host system. Procedures may be needed before and after replacement to protect the data. |
|
|
Repair of a connectivity component within an Oracle Big Data Appliance rack. No downtime of the rack is required; however, individual components may require downtime. |
|
|
Repair of the part requires shutting down one Big Data Appliance server. No downtime of the rack is required; however, individual servers may require downtime and temporary removal from the cluster. Rebalancing the workload and data duplication may temporarily affect performance. If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance" for additional information. |
|
The disk controllers in Sun Fire servers have battery-backed write cache to accelerate write performance. If the battery charge capacity degrades such that the battery cannot protect the cached data for a power loss of 48 hours or more, then the write cache is disabled and the disk controller switches to write through mode. This results in reduced write performance but no data loss. Sun Fire servers generate an alert when the battery charge is insufficient, when the temperature is high, and when the battery should be replaced.
Battery charge capacity degrades over time, and the life expectancy of a battery is inversely proportional to the operating temperature. The worst-case life expectancy of a battery in an Oracle Big Data Appliance rack is as follows:
Inlet Ambient Temperature | Battery Lifetime |
---|---|
< 25 degrees Celsius (77 degrees Fahrenheit) | 3 years |
< 32 degrees Celsius (90 degrees Fahrenheit) | 2 years |
Oracle replaces failed batteries at no extra charge if the battery charge capacity in the disk controllers falls below the minimum threshold. As part of Oracle Premier Support for Systems, Oracle attempts to proactively replace the batteries in an Oracle Big Data Appliance rack before the end of the estimated lifetime, on a best effort basis.
This section describes the light-emitting diodes (LEDs) in an Oracle Big Data Appliance rack. It contains these topics:
Table B-2 describes the LED color codes on Sun Fire X4270 M2 servers.
Table B-2 LED Status Descriptions
Component | LED Status |
---|---|
Fan module |
|
Power supply |
|
Servers |
|
Table B-3 describes the color codes of the LEDs on Sun Datacenter InfiniBand Switch 36 switches.
Table B-3 Sun Datacenter InfiniBand Switch 36 LED Status Descriptions
Component | LED Status |
---|---|
Chassis |
|
Link status |
|
Network management ports |
Link Speed LED:
Activity LED:
|
Power supply |
|
Table B-4 lists the replaceable parts for Sun Fire servers, which are covered under the Oracle Premier Support for Systems warranty.
Note:
Oracle Big Data Appliance ships with two spare drives. If a drive is faulty, then the customer can replace the drive before an Oracle service representative arrives if circumstances warrant immediate action.Table B-4 Replacement Parts for a Sun Fire X4270 M2 Server
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
150-3993 |
Battery, 3V, 390 MAH, LITH, COIN |
BDA-O |
See Section 4.6, "Servicing the Server Battery" in Sun Fire X4270 M2 Server Service Manual at
|
300-2235 |
Power supply, A249, 1200W, 12V, 2U, RoHS:Y |
HS |
See Section 3.4, "Servicing Power Supplies" in Sun Fire X4270 M2 Server Service Manual at
|
350-1502 |
Universal rack mount kit |
BDA-O |
|
371-4743 |
4 GB USB 2.0 flash drive, RoHS:Y |
BDA-O |
Not applicable |
371-4966 |
LV DIMM, 8 GB, DDR3, 1RX4, 1333 MHz |
BDA-O |
See Section 4.2, "Servicing Memory Modules (DIMMs)" in Sun Fire X4270 M2 Server Service Manual at
|
371-4982 |
6 Gigabit SAS RAID PCI battery module, RoHS:Y (LION), BBU-08 |
BDA-O |
|
375-3696 |
InfiniBand (CX2) dual port CX2 4x QDR PCI-e |
BDA-O |
|
375-3701 |
6 Gbps SAS RAID disk PCIe HBA, RoHS:Y |
BDA-O |
Note: Do not run any controller commands in the service manual when replacing the disk. |
530-3927 |
Cable, PDB, MB, 1U+2U, ribbon |
BDA-O |
See Section 5.10, "Servicing Cables " in Sun Fire X4270 M2 Server Service Manual at
|
530-4228 |
Cable, mini-SAS, 36 POS LONG, LY, RoHS:Y |
BDA-O |
See Section 5.10, "Servicing Cables" in Sun Fire X4270 M2 Server Service Manual at
|
541-2075 |
Bus_bar, power, 1U+2U, RoHS:Y |
BDA-O |
See Section 5.6, "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-2884 |
Assembly, riser, X8, X8, 2U, PCI-E, RoHS:Y |
BDA-O |
See Section 4.4, "Servicing PCIe Risers" in Sun Fire X4270 M2 Server Service Manual at
|
541-3310 |
Xeon Heatsink with grease, RoHS:Y, 2U |
BDA-O |
See Section 4.7, "Servicing CPUs" in Sun Fire X4270 M2 Server Service Manual at
|
541-3356 |
x8/x8 switched PCIe riser assembly, RoHS:Y with the following:
|
BDA-O |
|
541-4081 |
System board assembly, RoHS:Y |
BDA-O |
|
541-4124 |
Fan deck, Hyde, RoHS:Y |
BDA-O |
See Section 5.3, "Servicing the Fan Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4222 |
Assembly, fan, CR, 2U, RoHS:Y |
HS |
See Section 3.3, "Servicing Fan Modules" in Sun Fire X4270 M2 Server Service Manual at
|
541-4223 |
Power distribution board, 2U, RoHS:Y |
BDA-O |
See Section 5.6, "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4304 |
Indicator, right, Hyde 12/24, RoHS:Y |
BDA-O |
See Section 5.5, "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at
|
541-4305 |
Assembly, disk, SAS2, XP_DC, Hyde, RoHS:Y |
BDA-O |
See Section 5.2, "Servicing the SAS Expander Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4306 |
Assembly, connector board bracket, Hyde |
BDA-O |
See Section 5.7, "Servicing the Connector Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4363 |
12-slot disk backplane, RoHS:Y |
BDA-O |
See Section 5.4, "Servicing the Disk Backplane" in Sun Fire X4270 M2 Server Service Manual at
|
541-4371 |
Indicator, left, Hyde 12/24, RoHS:Y |
BDA-O |
See Section 5.5, "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at
|
560-2952 |
Cable kit, Hyde, RoHS:Y with the following:
|
BDA-O |
Refer to the entries for the individual items in the kit. |
7010036 |
FRU DR 3 TB 3.5-inch SAS/7200, CORAL |
-- |
See Section 3.2, "Servicing Storage Drives and Boot Drives" in Sun Fire X4270 M2 Server Service Manual at
Note: Do not run any controller commands in the service manual when replacing the disk. |
7012433 |
3.06 GHz processor |
BDA-O |
See Section 4.7, "Servicing CPUs" in Sun Fire X4270 M2 Server Service Manual at
|
Table B-5 lists the replaceable parts for the Sun Datacenter InfiniBand Switch 36, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures reference the Sun Datacenter InfiniBand Switch 36 Service Manual at
http://docs.oracle.com/cd/E26698_01/index.html
See "Cables and Cable Accessories for an Oracle Big Data Appliance Rack" for information about InfiniBand cables.
Table B-5 Replacement Parts for the Sun Datacenter InfiniBand Switch 36
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
300-2299 |
A247A 760 watt power supply, RoHS:Y |
HS |
See "Servicing Power Supplies" at
|
350-1312 |
Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y |
HS |
See "Servicing Fans" at
|
371-2210 |
CR2032 3V battery, RoHS:Y |
IR |
See "Servicing the Battery" at
|
541-3495 |
Sun Datacenter InfiniBand Switch 36, RoHS:YL |
IR |
|
594-6603 |
10 Gbps QSFP short wavelength transceiver |
IR |
See "Servicing Data Cables" at
|
Table B-6 lists the replaceable parts for the Sun Network QDR InfiniBand Gateway Switch, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures refer to the Sun Network QDR InfiniBand Gateway Switch Service Manual at
http://docs.oracle.com/cd/E26699_01/index.html
See "Cables and Cable Accessories for an Oracle Big Data Appliance Rack" for information about InfiniBand cables.
Table B-6 Replacement Parts for the Sun Network QDR InfiniBand Gateway Switch
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
300-2299 |
760 watt power supply, RoHS:Y |
HS |
See "Servicing Power Supplies" at
|
350-1312 |
Fan module, RoHS:Y |
HS |
See "Servicing Fans" at
|
371-2210 |
CR2032 3V battery, RoHS:Y |
IR |
See "Servicing the Battery" at
|
594-6603 |
10 Gbps QSFP short wavelength transceiver |
IR |
See "Servicing Data Cables" at
|
7014378 |
Assembly, system, NM2-Gateway |
IR |
|
Table B-7 lists replaceable parts for the Cisco Ethernet switch, which are covered under the Oracle Premier Support for Systems warranty.
See Also:
Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide athttp://www.cisco.com/en/US/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html
Table B-7 Replacement Parts for Cisco Catalyst Ethernet Switch
Part Number | Description | Repair Category | Repair |
---|---|---|---|
7055121 |
Cooling fan |
HS |
See Chapter 4 of Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
7055122 |
Cisco Catalyst 4948 switch, RoHS:Y |
IR |
See Chapter 3 of Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
7055123 |
Power supply |
HS |
See Chapter 4 of Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
Table B-8 lists the replacement parts for the KVM switch and KMM tray components, which are covered under the Oracle Premier Support for Systems warranty.
See Also:
MergePoint Unity Switch Installer/User Guide for repair instructions atTable B-8 Replacement Parts for KVM Switch and KMM Tray Components
Part Number | Description | Repair Category | Repair |
---|---|---|---|
371-4778 |
Assembly, KMM, with Japanese keyboard and mouse module |
IR |
See Chapter 2 of MergePoint Unity Switch Installer/User Guide |
371-4779 |
Avocent MPU4032DAC-001 32-port KVM switch, RoHS:Y |
IR |
See Chapter 2 of MergePoint Unity Switch Installer/User Guide |
371-4780 |
Avocent KMM drawer with United States keyboard, RoHS:Y |
IR |
See Chapter 2 of MergePoint Unity Switch Installer/User Guide |
371-4781 |
Avocent (DSRIQ-USB) DB 15 M to RJ45/USB KVM adapter, RoHS:Y |
IR |
See Chapter 2 of MergePoint Unity Switch Installer/User Guide |
Table B-9 lists the replacement parts for the power distribution units (PDUs), which are covered under the Oracle Premier Support for Systems warranty.
Because of the number of cables and connections, Oracle recommends shutting down the Oracle Big Data Appliance rack during the replacement of power distribution unit parts.
See Also:
Sun Rack II Power Distribution Units User's Guide for repair instructions atTable B-9 Replacement Parts for Power Distribution Units
Part Number | Description | Repair Category | Repair |
---|---|---|---|
180-2379 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y |
HS |
Not applicable |
180-2380 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y |
HS |
Not applicable |
371-3995 |
Three-phase PDU: 15 kVA, IEC309 60A, 4-pin, 250 VAC, three-phase IP67, North America, RoHS:Y |
IR |
See Chapter 3 of Sun Rack II Power Distribution Units User's Guide |
371-4000 |
Three-phase PDU: 15 kVA, 5-pin, IEC309 32A, 5-pin 230/400V, three-phase IP44, international, RoHS:Y |
IR |
See Chapter 3 of Sun Rack II Power Distribution Units User's Guide |
371-4199 |
Single-phase PDU: 15 kVA, with three 30A/250V 2-pole/3-wire NEMA L6-30P plugs, North America, RoHS:Y |
IR |
See Chapter 3 of Sun Rack II Power Distribution Units User's Guide |
371-4201 |
Single-phase PDU: 15 kVA, with three blue 32A/240V splash-proof 2-pole/3-wire IEC 60309 plugs, international, RoHS:Y |
IR |
See Chapter 3 of Sun Rack II Power Distribution Units User's Guide |
Table B-10 lists the replacement cables and cable accessories for an Oracle Big Data Appliance rack, which are covered under the Oracle Premier Support for Systems warranty.
See Also:
Sun Network QDR InfiniBand Gateway Switch Service Manual at
Sun Datacenter InfiniBand Switch 36 Service Manual at
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at
http://www.cisco.com/en/US/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html
Table B-10 Replacement Cables for an Oracle Big Data Appliance Rack
Part Number | Description | Repair Category | Repair |
---|---|---|---|
350-1287 |
Slim rail, CMA, 1U-2U for Sun Fire servers |
BDA-O |
|
350-1519 |
Serial cable kit, RoHS:Y with the following:
|
HS |
See "Understanding Cabling" in the Sun Datacenter InfiniBand Switch 36 Installation Guide at
|
530-4403 |
4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y |
HS |
Note: Redundancy is lost during cable replacement. |
530-4404 |
4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y |
HS |
|
530-4415 |
4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y |
HS |
|
530-4432 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4433 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4434 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4435 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4436 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4437 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, orange, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4438 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |