Oracle® Virtual Networking for ESX Hosts Installation and Boot Guide

Exit Print View

Updated: July 2016
 
 

Verify the HCA Firmware Version

You can check the HCA version information from the Oracle Fabric Interconnect.

  1. Determine your HCA firmware version by using either of the following commands:
    • Oracle Fabric Interconnect

      show physical-server hostname hca 

      where hostname is the name of the ESXi host.

      show physical-server kingston hca
      -----------------------------------------------------------------
      lid               7
      node-guid         0002c903000a9f7a
      board-id          MT_0A50120005
      device-id         26418
      firmware-version  2.7.0
      hardware-version  unknown
      option-version    2.8.7
      -----------------------------------------------------------------
    • Host

      # ibstat
      CA 'mlx4_1'        
          CA type: MT26428       
          Number of ports:2 
          Firmware version: 2.9.1000         
          Hardware version: 176        
          Node GUID: 0x0002c9030057b57c      
          System image GUID: 0x0002c9030057b57f
      # ibv_devinfo
      hca_id: mlx4_1
        transport:        InfiniBand (0)       
        fw_ver:           2.9.1000        
        node_guid:          0002:c903:0057:b57c
        sys_image_guid:       0002:c903:0057:b57f        
        vendor_id:        0x02c9        
        vendor_part_id:     26428       
        hw_ver:           0xB0        
        board_id:         MT_0FC0110009       
       phys_port_cnt:       2
  2. Record the LID, board-ID, device ID, firmware version, and option ROM version.
  3. Perform any of the following steps depending on your requirement:
    • Install an HCA card or exchange an HCA card for firmware upgrade.

    • Upgrade the firmware or option ROM.

    • Remove the old host drivers if the firmware, hardware, and software prerequisites are met.