Oracle® Solaris Cluster Data Service for Oracle JD Edwards EnterpriseOne Enterprise Server Guide

Exit Print View

Updated: July 2014, E40215–01
 
 

Oracle HA for JD Edwards EnterpriseOne Enterprise Server Extension Properties

Extension properties for the Oracle HA for JD Edwards EnterpriseOne Enterprise Server EnterpriseOne Enterprise Server resource type are described below.

For details about system-defined properties, see the r_properties(5) man page and the rg_properties(5) man page.

ORCL.JDE_Enterprise_Server Extension Properties

The ORCL.JDE_Enterprise_Server resource type represents the JD Edwards EnterpriseOne Enterprise Server in an Oracle Solaris Cluster configuration. The extension properties of this resource type are as follows:

Monitor_retry_interval

Indicates the time in minutes, over which the failures of the fault monitor are counted, and corresponds to the –t option passed to the pmfadm command. If the number of times the fault monitor fails exceeds the value of Monitor_retry_count, the fault monitor is not restarted by the process monitor facility.

Data Type: Integer

Default: 2

Tunable: Any time

Probe_timeout

This property is the timeout value (in seconds) used by the fault monitor to probe a JD Edwards EnterpriseOne Enterprise Server instance.

Data Type: Integer

Default: 30

Tunable: Any time

Child_mon_level

This property provides control over the processes that are monitored through the Process Monitor Facility (PMF). This property denotes the level to which the forked children processes are monitored. Omitting this property or setting this property to the default value is the same as omitting the –C option for pmfd (1M) : all children (and their descendents) are monitored.

Data Type: Integer

Default: -1

Tunable: At creation

Validate_command

This property validates the application.

Data Type: String

Default: ""

Tunable: When disabled

Network_aware

This property determines whether the application uses a network.

Data Type: Boolean

Default: TRUE

Tunable: At creation

Stop_signal

This property controls the stop signal sent to the application.

Data Type: Integer

Default: 15

Tunable: When disabled

Failover_enabled

This property determines whether to fail over when the Retry_count is exceeded during the Retry_count.

Data Type: Boolean

Default: TRUE

Tunable: When disabled

Log_Level

This property determines the log level for event-based traces.

Data Type: Enum

Default: INFO

Tunable: Anytime

Debug_Level

This property controls the debug level for the control script and its functions.

Data Type: Integer

Default: 0

Tunable: Anytime

JDE_USER

This property determines the username used to run the application.

Data Type: String

Default: None

Tunable: When disabled

JDE_HOME

This property defines the installation directory for the JD Edwards EnterpriseOne Enterprise Server binaries.

Data Type: String

Default: None

Tunable: When disabled