먼저 LUN 레벨 정보 표시 절차를 통해 시스템에 표시되는 장치를 식별해야 합니다. 이 절차에서는 패브릭 연결 호스트 포트에 연결된 구성되지 않은 모든 패브릭 장치를 구성하는 방법에 대해 설명합니다. 예로 사용되는 포트는 c0입니다.
# cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 fc-fabric connected unconfigured unknown c0::50020f2300006077 disk connected unconfigured unknown c0::50020f23000063a9 disk connected unconfigured unknown c0::50020f2300005f24 disk connected unconfigured unknown c0::50020f2300006107 disk connected unconfigured unknown c1 fc-private connected configured unknown c1::220203708b69c32b disk connected configured unknown c1::220203708ba7d832 disk connected configured unknown c1::220203708b8d45f2 disk connected configured unknown c1::220203708b9b20b2 disk connected configured unknown
# cfgadm -c configure c0
# cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 fc-fabric connected configured unknown c0::50020f2300006077 disk connected configured unknown c0::50020f23000063a9 disk connected configured unknown c0::50020f2300005f24 disk connected configured unknown c0::50020f2300006107 disk connected configured unknown c1 fc-private connected configured unknown c1::220203708b69c32b disk connected configured unknown c1::220203708ba7d832 disk connected configured unknown c1::220203708b8d45f2 disk connected configured unknown c1::220203708b9b20b2 disk connected configured unknown
다음 코드 예에서는 c0::50020f2300006077 및 c0::50020f2300006107로 표시된 물리적 장치에 각각 네 개의 LUN이 구성되어 있음을 보여 줍니다. c0::50020f23000063a9 및 c0::50020f2300005f24로 표시된 물리적 장치에는 각각 두 개의 LUN이 구성되어 있습니다.
# cfgadm -al -o show_SCSI_LUN c0 Ap_Id Type Receptacle Occupant Condition c0 fc-fabric connected configured unknown c0::50020f2300006077,0 disk connected configured unknown c0::50020f2300006077,1 disk connected configured unknown c0::50020f2300006077,2 disk connected configured unknown c0::50020f2300006077,3 disk connected configured unknown c0::50020f23000063a9,0 disk connected configured unknown c0::50020f23000063a9,1 disk connected configured unknown c0::50020f2300005f24,0 disk connected configured unknown c0::50020f2300005f24,1 disk connected configured unknown c0::50020f2300006107,0 disk connected configured unknown c0::50020f2300006107,1 disk connected configured unknown c0::50020f2300006107,2 disk connected configured unknown c0::50020f2300006107,3 disk connected configured unknown
이 절에서는 다중 경로 기능이 사용으로 설정된 시스템에서 패브릭 장치 구성 단계를 수행하는 방법에 대해 설명합니다.
패브릭 연결 호스트 포트에 연결된 장치는 기본적으로 구성되어 있지 않으므로 시스템에서 사용할 수 없습니다. cfgadm configure 및 cfgadm unconfigure 명령을 사용하여 패브릭 장치에 대한 장치 노드 생성을 관리할 수 있습니다. 자세한 내용은 cfgadm_fp(1M)을 참조하십시오. 이 절의 절차에서는 시스템에 표시되는 패브릭 장치를 감지하여 시스템에서 사용할 수 있도록 다중 경로 장치로 구성하는 단계에 대해 설명합니다.
사용자가 제공하고 cfgadm 명령으로 표시되는 장치 정보는 시스템 구성에 따라 다릅니다.