查找与 RAID 卷中的驱动器相关的错误消息

某个驱动器发生故障时,系统控制台上将显示有关该驱动器以及包括该驱动器的 RAID 卷的错误消息。例如,系统控制台上显示以下消息表明卷 905 已因丢失 PhysDiskNum 1 而被降级:

Mar 16 16:28:26 hostname scsi: /pci@400/pci@2/pci@0/pci@e/scsi@0 (mpt_sas0):
Mar 16 16:28:26 hostname     PhysDiskNum 1 with DevHandle 0xc in slot 0 for
enclosure with handle 0x0 is now offline
Mar 16 16:28:26 hostname scsi: /pci@400/pci@2/pci@0/pci@e/scsi@0 (mpt_sas0):
Mar 16 16:28:26 hostname     PhysDiskNum 1 with DevHandle 0xc in slot 0 for
enclosure with handle 0x0 is now , active, out of sync
Mar 16 16:28:26 hostname scsi: WARNING: /pci@400/pci@2/pci@0/pci@e/scsi@0
(mpt_sas0):
Mar 16 16:28:26 hostname     Volume 905 is degraded
Mar 16 16:28:26 hostname scsi: /pci@400/pci@2/pci@0/pci@e/scsi@0 (mpt_sas0):
Mar 16 16:28:26 hostname     Volume 0 is now degraded
Mar 16 16:28:26 hostname scsi: WARNING: /pci@400/pci@2/pci@0/pci@e/scsi@0
(mpt_sas0):
Mar 16 16:28:26 hostname     Volume 905 is degraded
  • 显示 /var/adm/messages 文件中最近的系统控制台消息。
    # more /var/adm/messages*
    

    请参阅服务器的服务手册中有关这些消息和其他消息的信息。

相关信息