acl452 - The ACL 4∕52 Automated Tape Library
SUNWsamfs
The ACL 4∕52 tape library supports 48 DLT tape cartridges and 4 DLT tape drives. The library has a 4 slot import∕export unit that may be used to import or export media into the library. These import∕export slots may also be used as storage slots thus extending the storage capacity to 52 slots.
The ACL 4∕52 should NOT
be configured with auto-clean or auto-load when
running StorageTek QFS and Oracle HSM software. Auto-load may be used during
initial loading of cartridges as long as the StorageTek QFS and Oracle HSM
software is not running.
To import media, the door on the ACL 4∕52 must first be opened. To open the
door, issue the
export
(1m)
command, then push the OPEN button on the ACL 4∕52
front panel. The door should open and you may place media in any of
the slots. You may then close the door by pressing the CLOSE button then
manually closing the door when the ACL 4∕52 display indicates
that it is ready.
The StorageTek QFS and Oracle HSM software will not recognize the new media
until the
import
(1m)
command is issued.
Anytime
you close the door, you must issue the
import
function.
To export media, use the
move
(1m)
command to move media into the import∕export unit then issue
the
export
(1m)
command.
Push the OPEN button on the ACL 4∕52 front panel to open the door.
If the door is already open, you must close the door and issue the
import
command before attempting to move media into the import∕export
unit.
The slot numbers for the import∕export unit are 48, 49, 50 and 51.
Note: After opening or closing the door, the ACL 4∕52 goes offline until it has re-initialized. This will cause delays since the library must become online before any commands may be issued.
mcf
The configuration file for the StorageTek QFS and Oracle HSM software