Environmental
Specifications
Oracle 6.4 TB NVMe SSDs operate and are stored in an environment defined by the parameters and
specifications in the following table.
|
|
Operating temperature
|
-
0 to 35°C ambient, 0 to 70°C case with specified
airflow
-
Operational environment: 5°C to 35°C (dry bulb)
|
Non-operating temperature
|
Storage and transit environment: –55°C to 95°C (dry
bulb)
|
Temperature monitoring
|
-
Temperature monitoring in-band and by way of SMBUS
-
Thermal throttling when approaching maximum composite
throttling temperature
See Troubleshooting Oracle 6.4 TB NVMe SSD Cooling for more information
on thermal throttling.
-
Thermal shutdown when drive exceeds maximum component
temperature
|
Dry bulb temperature
|
Maximum dry bulb temperature is derated by 3.3°C per 1000 m
above 500 m
|
Altitude (Simulated)
|
-
Operating: -1,000 to 10,000 ft
-
Non-operating: -1,000 to 40,000 ft
|
Relative humidity range
|
-
Operational environment: 8% to 80%
noncondensing
-
Storage and transit environment: 5% to 95%
noncondensing
-
Non-operating: -20°C to 75°C noncondensing
|
Thermal sensors
|
|
Airflow requirement
|
More than 450 LFM (linear feet/minute) at 25/35°C, airflow
towards the connector
|
|
Note -
For specific site planning guidelines and best practices, refer to the server documentation
and product notes for your server. Refer to the system site planning guide, if available.