Table 3-4 describes the information on the pages: Data Input Notes apply only on the Insert page.
Table 3-4 Local SCCP Users Elements
Element (* indicates required field) | Description | Data Input Notes |
---|---|---|
*Signaling Network Element Name | Identifies the Signaling Network Element Name to which the Local SCCP User is being added. | View-only |
*SSN | The specific subsystem number served by this Local SCCP User. This field is used to route incoming messages to the application hosting this SSN. |
Format: Numeric Range: 2 - 254 |
*SS7 Domain | The SS7 domain of the selected Local Signaling Point. |
Format: List Range: ANSI, ITUI - ITU International, ITUN - ITU National, and ITUN24 - ITU National 24-bit Note: MD-IWF does not support ITUN24 - ITU National 24-bit point codes. |
*Local Point Code | The point code of the Local Signaling Point associated with this Local SCCP User. Local signaling points are defined at Local Signaling Points). | (see
Format: List of all configured LSPs associated with the selected Signaling Network Element Name. Range: 1 entry |
*Application Name | Application Name to configure as the Local SCCP User. |
Format: List of all configured applications. If there is only one application configured, that Application Name appears in this field as a view-only entry. Range: 1 entry |