Local SCCP Users elements

Table 3-4 describes the information on the SS7/Sigtran > Configuration > Local SCCP Users pages: Data Input Notes apply only on the Insert page.

Table 3-4 Local SCCP Users Elements

Element (* indicates required field) Description Data Input Notes
*Signaling Network Element Name Identifies the Signaling Network Element Name to which the Local SCCP User is being added. View-only
*SSN The specific subsystem number served by this Local SCCP User. This field is used to route incoming messages to the application hosting this SSN.

Format: Numeric

Range: 2 - 254

*SS7 Domain The SS7 domain of the selected Local Signaling Point.

Format: List

Range: ANSI, ITUI - ITU International, ITUN - ITU National, and ITUN24 - ITU National 24-bit

Note:

MD-IWF does not support ITUN24 - ITU National 24-bit point codes.
*Local Point Code The point code of the Local Signaling Point associated with this Local SCCP User. Local signaling points are defined at SS7/Sigtran > Configuration > Local Signaling Points (see Local Signaling Points).

Format: List of all configured LSPs associated with the selected Signaling Network Element Name.

Range: 1 entry

*Application Name Application Name to configure as the Local SCCP User.

Format: List of all configured applications.

If there is only one application configured, that Application Name appears in this field as a view-only entry.

Range: 1 entry