Oracle® Communications EAGLE Database Administration - GWS User's Guide Release 46.6 E93314 Revision 1 |
|
![]() Previous |
![]() Next |
This procedure is used to add an allowed destination point code (DPC) screen to the database using the ent-scr-dpc
command. The parameters used by the ent-scr-dpc
command are shown in the Gateway Screening Attributes section. The general rules that apply to configuring gateway screening entities are shown in the Gateway Screening Configuration section.
The examples in this procedure are used to add the allowed DPC screen data shown in Table 9-1 and based on the example configurations shown in Figure 2-3, Figure 2-5, and Figure 2-9.
Table 9-1 Example Gateway Screening Allowed DPC Configuration Table
Screening Reference | NI | NC | NCM | NSFI | NSR |
---|---|---|---|---|---|
gws9 |
003 |
003 |
003 |
blkdpc |
gw12 |
iec |
070 |
070 |
025&&135 |
blkdpc |
gws9 |
isp2 |
073 |
200 |
059 |
isup |
isp2 |
tup1 |
050 |
034 |
049 |
isup |
tup1 |
Note:
If you using multiple-part ITU national point codes with gateway screening, see the 14-Bit ITU National Point Code Formats section.The allowed DPC screen can reference one of the following screens.
Verifying the Gateway Screening Configuration
Enter the following commands to verify that these screens are in the database.
rtrv-scr-blkdpc:all=yes
rtrv-scr-destfld:all=yes
rtrv-scr-cgpa:all=yes
rtrv-scr-isup:all=yes
Gateway Screening Configuration Procedures
If the desired screen is not in the database, perform one of these procedures to add the desired screen to the database or change an existing screen in the database.
Specifying a Range of Values
A range of values can be specified for the point code parameters ni
, nc
, or ncm
.
If a range of values is specified for any of these parameters, and the value of the other parameters match existing values for the screening reference name, the range of values for the point code parameter cannot include any values for that parameter that are currently provisioned for the screening reference name.
For example, screening reference name scr1
contains these entries:
SR NI NC NCM NSFI NSR/ACT SCR1 240 001 010 CGPA ------ SCR1 241 010 020 STOP ------
Another entry for screening reference scr1
with the ni
value of 240 and the nc
value of 001 cannot be specified if the range of values for the ncm
parameter includes the value 010.
The ANSI point code parameter values can be specified as a single value, a range of values, or with an asterisk (*). The asterisk specifies all possible values for the ni
, nc
, and ncm
parameters. Table 9-2 shows the valid combinations of these parameter values.
Table 9-2 Valid Value Combinations for ANSI Point Code Parameters
NI | NC | NCM |
---|---|---|
Single Value |
Single Value |
Single Value |
Single Value |
Single Value |
Range of Values |
Single Value |
Single Value |
Asterisk |
Single Value |
Range of Values |
Asterisk |
Single Value |
Asterisk |
Asterisk |
Range of Values |
Asterisk |
Asterisk |
Asterisk |
Asterisk |
Asterisk |
A range of values can also be specified for an ITU-I or 24-bit ITU-N point code parameter using a combination of asterisks (*) and single values for the point code parameters. Table 9-3 shows the valid combinations of the ITU-I parameter values. Table 9-4 shows the valid combinations of the 24-bit ITU-N parameter values.
Table 9-3 Valid Value Combinations for ITU-I Point Code Parameters
ZONE | AREA | ID |
---|---|---|
Single Value |
Single Value |
Single Value |
Single Value |
Single Value |
Asterisk |
Single Value |
Asterisk |
Asterisk |
Asterisk |
Asterisk |
Asterisk |
Table 9-4 Valid Value Combinations for 24-Bit ITU-N Point Code Parameters
MSA | SSA | SP |
---|---|---|
Single Value |
Single Value |
Single Value |
Single Value |
Single Value |
Asterisk |
Single Value |
Asterisk |
Asterisk |
Asterisk |
Asterisk |
Asterisk |
Figure 9-3 Adding an Allowed DPC Screen
Sheet 1 of 5
Sheet 2 of 5
Sheet 3 of 5
Sheet 4 of 5