Manipulation Rule
- Type diameter-manip-rules to continue and enter individual policy attributes. The system prompt changes to let you know that you can begin configuring individual parameters.
- name—Enter the name of this manipulation rule. This value will be referenced in when creating a chain of rules.
- descr-avp-code—Enter a description of the AVP code to manipulate.
- msg-cmd-code—Enter the command code number of the message to execute the manipulation on.
- msg-type—Set this to the type of message this manipulation applies to as request, response, or all.
- avp-code—Enter the AVP by code number where this manipulation applies. You can add a multi instance identifier to the end of the avp code value, enclosed in brackets.
-
avp-type—Set this to the data type of the content of the match field. Refer to the Diameter standards document for the encodings of individual AVPs. Valid values are:
none | octet-string | octet-hex | integer32 | unsignedint32 | address | diameteruri | enumerated | grouped
- match-value—Enter the value within the match-field to find and make a positive match on.
- action—Enter either none, add, delete, store, diameter-manip, group-manip, find-replace-all, or replace as the action to take after making a positive match on the previously entered match-value.
- new-value—Enter the value that should be added or replaced in the old match-value’s position.
- Type done and continue.