Example 1
Example 1 screens the messages in a linkset for the following criteria. Figure 2-3 shows the screening order the EAGLE uses and the order that the screens must be entered into the database.
- Allow into the EAGLE messages containing the
following items
The OPC 001-001-001
The DPC 003-003-003
The calling party address (CGPA) 006-006-006, with the subsystem number of 253 and the routing indicator (
ri
) ofdpc
and the SCCP message type of UDTThe called party address (CDPA) 003-003-003 with the subsystem number of 001, and the SCMG format ID of 050
The allowed affected point code (AFTPC) of 008-008-008 with the subsystem number of 250
- Block from the EAGLE messages containing these items
The OPC 001-002-002
The DPC 004-004-004
- The message that passes the gateway screening
criteria is copied for the STPLAN application (specified with the
actname
parameter and the name of the gateway screening stop action set containing theCOPY
gateway screening stop action).
Figure 2-3 Gateway Screening Configuration - Example 1