Example 2
Example 2 screens the messages in a linkset for the following criteria. Figure 2-4 shows the screening order the EAGLE uses and the order that the screens must be entered into the database.
- Allow messages containing the following items into
the EAGLE
The following SIO information:
- The network indicator code of 2 (
nic=2
) - The service indicator of 3 (
si=3
) - Message priorities ranging from 1 to 3 (
:pri=1&&3
)
The calling party address (CGPA) 7-100-4, with the subsystem number of 254 and the routing indicator (
ri
) of*
, and the SCCP message type of UDTSThe called party address (CDPA) 5-117-2 with the subsystem number of 254
- The network indicator code of 2 (
- Block messages containing the OPC 4-250-3 from the EAGLE
Figure 2-4 Gateway Screening Configuration - Example 2