If the IPSG32 GPL is running on the location specified
by the
loc parameter, then
gtt and
nosccp are the only valid values
for the
DATA parameter. If the GPL is
anything but the IPSG32 GPL, the
data=nosccp parameter cannot be used
for the card at that location.
For the
chg-card command, if the card is
type=slic with
data=gtt and is changed to
type=enet/enetb, then
data must be changed to
nosccp first.
For the
ent-card command, the
DATA parameter can only be equal to
DN or
ELAP when the
type=dsm and
appl=siphc parameters are specified.
For the
rept-stat-card command, the
data=nosccp parameter can be
specified only when the
appl=ipsg parameter is specified.
Recovery