23.5 Three Phase Power Distribution Unit Cabling Tables

These tables show the cabling routes from each three-phase power distribution unit (PDU) to the power supplies configured in each Oracle Exadata Storage Expansion Rack.

The cables are terminated to PDU-A on the left (when looking at the rear of the rack), and routed to the right to enter cable management arm (CMA). The cables are bundled in groups of four. The PDU connections list the group and outlet on the PDU. So, for example, G5-5 refers to group 5 outlet 5.

The following tables are in this section:

  • Table 23-28 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X8M-2
  • Table 23-29 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X8-2
  • Table 23-30 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X7-2
  • Table 23-31 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X6-2
  • Table 23-32 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X5-2
  • Table 23-33 Three Phase PDU Cabling for Oracle Exadata Storage Expansion X4-2 Full Rack, and Oracle Exadata Storage Expansion X3-2 Full Rack
  • Table 23-34 Three Phase PDU Cabling for Oracle Exadata Storage Expansion X4-2 Half Rack, and Oracle Exadata Storage Expansion X3-2 Half Rack
  • Table 23-35 Three Phase PDU Cabling for Oracle Exadata Storage Expansion X4-2 Quarter Rack, and Oracle Exadata Storage Expansion X3-2 Quarter Rack
  • Table 23-36 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers
  • Table 23-37 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Half Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers
  • Table 23-38 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Quarter Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion Rack X8M-2.

Table 23-28 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X8M-2

Rack Unit PDU-A/PSU 0 PDU-B/PSU 1 Cable Length

U42

G5-4

G2-2

2 meters

U41

G5-2

G2-4

2 meters

U40

G5-1

G2-5

2 meters

U39

G5-6

G2-0

2 meters

U37

G3-5

G0-1

2 meters

U35

G3-0

G0-6

2 meters

U33

G5-5

G2-1

2 meters

U31

G5-3

G2-3

2 meters

U29

G4-2

G1-4

2 meters

U27

G3-2

G0-4

2 meters

U26

G5-0

G2-6

2 meters

U25

G4-5

G1-1

2 meters

U24

G3-1

G0-5

2 meters

U23

G4-1

G1-5

2 meters

U22

G1-6

G4-0

2 meters

U21

G2-6

G5-0

2 meters

U20

G1-5

G4-1

2 meters

U19

G1-1

G4-5

2 meters

U18

G1-4

G4-2

2 meters

U17

G2-1

G5-5

2 meters

U16

G2-3

G5-3

2 meters

U14

G0-5

G3-1

2 meters

U12

G2-5

G5-1

2 meters

U10

G0-3

G3-3

2 meters

U8

G1-3

G4-3

2 meters

U6

G2-4

G5-2

2 meters

U4

G0-6

G3-0

2 meters

U2

G0-0

G3-6

2 meters

U1

G1-0

G4-6

3 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion Rack X8-2.

Table 23-29 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X8-2

Rack Unit PDU-A/PSU 0 PDU-B/PSU 1 Cable Length

U42

G5-6

G2-0

2 meters

U41

G5-3

G2-3

2 meters

U40

G3-5

G0-1

2 meters

U39

G4-3

G1-3

2 meters

U37

G5-2

G2-4

2 meters

U35

G3-2

G0-4

2 meters

U33

G4-2

G1-4

2 meters

U31

G5-1

G2-5

2 meters

U29

G3-6

G0-0

2 meters

U27

G4-1

G1-5

2 meters

U26

G3-1

G0-5

2 meters

U25

G4-0

G1-6

2 meters

U24

G3-0

G0-6

2 meters

U23

G2-6

G5-0

2 meters

U22

G1-5

G4-1

2 meters

U21

G2-4

G5-2

2 meters

U20

G1-4

G4-2

2 meters

U19

G0-6

G3-0

2 meters

U18

G2-3

G5-3

2 meters

U17

G0-2

G3-4

2 meters

U16

G0-1

G3-5

2 meters

U14

G1-3

G4-3

2 meters

U12

G1-2

G4-4

2 meters

U10

G1-1

G4-5

2 meters

U8

G2-2

G5-4

2 meters

U6

G0-0

G3-6

2 meters

U4

G2-1

G5-5

2 meters

U2

G2-0

G5-6

2 meters

U1

G1-0

G4-6

3 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion Rack X7-2.

Table 23-30 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X7-2

Rack Unit PDU-A/PSU 0 PDU-B/PSU 1 Cable Length

U42

G5-4

G2-2

2 meters

U41

G5-6

G2-0

2 meters

U40

G4-6

G1-0

2 meters

U39

G4-5

G1-1

2 meters

U37

G3-5

G0-1

2 meters

U35

G5-5

G2-1

2 meters

U33

G4-3

G1-3

2 meters

U31

G3-1

G0-5

2 meters

U29

G4-0

G1-6

2 meters

U27

G5-3

G2-3

2 meters

U26

G5-1

G2-5

2 meters

U25

G3-3

G0-3

2 meters

U24

G4-4

G1-2

2 meters

U23

G3-2

G0-4

2 meters

U22

G2-6

G5-0

2 meter

U21

G1-0

G4-6

2 meters

U20

G0-0

G3-6

2 meters

U19

G2-5

G5-1

2 meters

U18

G0-6

G3-0

2 meters

U17

G1-6

G4-0

2 meters

U16

G2-1

G5-5

2 meters

U14

G1-4

G4-2

2 meters

U12

G2-3

G5-3

2 meters

U10

G2-0

G5-6

2 meters

U8

G1-2

G4-4

2 meters

U6

G1-1

G4-5

2 meters

U4

G0-2

G3-4

2 meters

U2

G0-1

G3-5

2 meters

U1

G2-2

G5-4

3 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion Rack X6-2.

Table 23-31 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X6-2

Rack Unit PDU-A/PSU 0 PDU-B/PSU 1 Cable Length

U42

G5-4

G2-2

2 meters

U41

G5-5

G2-1

2 meters

U40

G3-6

G0-0

2 meters

U39

G5-6

G2-0

2 meters

U37

G5-3

G2-3

2 meters

U35

G5-0

G2-6

2 meters

U33

G5-2

G2-4

2 meters

U31

G4-4

G1-2

2 meters

U29

G4-2

G1-4

2 meters

U27

G4-1

G1-5

2 meters

U26

G5-1

G2-5

2 meters

U25

G3-5

G0-1

2 meters

U24

G3-4

G0-2

2 meters

U23

G3-3

G0-3

2 meters

U22

G3-2

G0-4

2 meter

U21

G3-0

G0-6

2 meters

U20

G2-4

G5-2

2 meters

U19

G2-3

G5-3

2 meters

U18

G2-2

G5-4

2 meters

U17

G2-1

G5-5

2 meters

U16

G1-6

G4-0

2 meters

U14

G1-5

G4-1

2 meters

U12

G1-4

G4-2

2 meters

U10

G1-2

G4-4

2 meters

U8

G1-0

G4-6

2 meters

U6

G0-6

G3-0

2 meters

U4

G0-4

G3-2

2 meters

U2

G0-2

G3-4

2 meters

U1

G0-0

G3-6

3 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion Rack X5-2.

Table 23-32 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack X5-2

Rack Unit PDU-A/PS-00 PDU-B/PS-01 Cable Length

U41

G4-5

G1-1

2 meters

U39

G5-6

G2-0

2 meters

U37

G5-3

G2-3

2 meters

U35

G5-0

G2-6

2 meters

U33

G4-6

G1-0

2 meters

U31

G4-4

G1-2

2 meters

U29

G4-2

G1-4

2 meters

U27

G3-6

G0-0

2 meters

U25

G3-5

G0-1

2 meters

U23

G3-3

G0-3

2 meters

U22

G2-5

G5-1

1 meter

U21

G3-0

G0-6

2 meters

U20

G2-4

G5-2

2 meters

U18

G2-2

G5-4

2 meters

U16

G1-6

G4-0

2 meters

U14

G2-0

G5-6

2 meters

U12

G1-4

G4-2

2 meters

U10

G1-2

G4-4

2 meters

U8

G1-0

G4-6

2 meters

U6

G0-6

G3-0

2 meters

U4

G0-4

G3-2

2 meters

U2

G0-2

G3-4

2 meters

U1

G0-0

G3-6

2 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion X4-2 Full Rack, and Oracle Exadata Storage Expansion X3-2 Full Rack.

Table 23-33 Three Phase PDU Cabling for Oracle Exadata Storage Expansion X4-2 Full Rack, and Oracle Exadata Storage Expansion X3-2 Full Rack

Rack Unit PDU-A/PS-00 PDU-B/PS-01 Cable Length

U39

G5-6

G2-0

2 meters

U37

G5-3

G2-3

2 meters

U35

G5-0

G2-6

2 meters

U33

G4-6

G1-0

2 meters

U31

G4-4

G1-2

2 meters

U29

G4-2

G1-4

2 meters

U27

G3-6

G0-0

2 meters

U25

G3-5

G0-1

2 meters

U23

G3-3

G0-3

2 meters

U22

G2-5

G5-1

1 meter

U21

G3-0

G0-6

2 meters

U20

G2-4

G5-2

2 meters

U18

G2-2

G5-4

2 meters

U16

G1-6

G4-0

2 meters

U14

G2-0

G5-6

2 meters

U12

G1-4

G4-2

2 meters

U10

G1-2

G4-4

2 meters

U8

G1-0

G4-6

2 meters

U6

G0-6

G3-0

2 meters

U4

G0-4

G3-2

2 meters

U2

G0-2

G3-4

2 meters

U1

G0-0

G3-6

2 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion X4-2 Half Rack, and Oracle Exadata Storage Expansion X3-2 Half Rack.

Table 23-34 Three Phase PDU Cabling for Oracle Exadata Storage Expansion X4-2 Half Rack, and Oracle Exadata Storage Expansion X3-2 Half Rack

Rack Unit PDU-A/PS-00 PDU-B/PS-01 Cable Length

U22

G3-1

G0-5

1 meter

U21

G3-0

G0-6

2 meters

U20

G2-4

G5-2

2 meters

U18

G2-2

G5-4

2 meters

U16

G1-6

G4-0

2 meters

U14

G2-0

G5-6

2 meters

U12

G1-4

G4-2

2 meters

U10

G1-2

G4-4

2 meters

U8

G1-0

G4-6

2 meters

U6

G0-6

G3-0

2 meters

U4

G0-4

G3-2

2 meters

U2

G0-2

G3-4

2 meters

U1

G0-0

G3-6

2 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion X4-2 Quarter Rack, and Oracle Exadata Storage Expansion X3-2 Quarter Rack.

Table 23-35 Three Phase PDU Cabling for Oracle Exadata Storage Expansion X4-2 Quarter Rack, and Oracle Exadata Storage Expansion X3-2 Quarter Rack

Rack Unit PDU-A/PS-00 PDU-B/PS-01 Cable Length

U22

G3-1

G0-5

1 meter

U21

G3-0

G0-6

2 meters

U20

G2-4

G5-2

2 meters

U8

G1-0

G4-6

2 meters

U6

G0-6

G3-0

2 meters

U4

G0-4

G3-2

2 meters

U2

G0-2

G3-4

2 meters

U1

G0-0

G3-6

2 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion Full Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers.

Table 23-36 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers

Rack Unit PDU-A/PS-00 PDU-B/PS-01 Cable Length

U41

G5-6

G2-0

2 meters

U39

G5-3

G2-3

2 meters

U37

G5-0

G2-6

2 meters

U35

G4-6

G1-0

2 meters

U33

G4-4

G1-2

2 meters

U31

G4-2

G1-4

2 meters

U29

G3-6

G0-0

2 meters

U27

G3-5

G0-1

2 meters

U25

G3-3

G0-3

2 meters

U24

G3-1

G0-5

2 meters

U23

N/A

G5-0

included

U22

G2-5

G5-1

1 meter

U21

G3-0

G0-6

2 meters

U20

G2-4

G5-2

2 meters

U18

G2-2

G5-4

2 meters

U16

G1-6

G4-0

2 meters

U14

G2-0

G5-6

2 meters

U12

G1-4

G4-2

2 meters

U10

G1-2

G4-4

2 meters

U8

G1-0

G4-6

2 meters

U6

G0-6

G3-0

2 meters

U4

G0-4

G3-2

2 meters

U2

G0-2

G3-4

2 meters

U1

G0-0

G3-6

2 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion Half Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers.

Table 23-37 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Half Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers

Rack Unit PDU-A/PS-00 PDU-B/PS-01 Cable Length

U24

G3-1

G0-5

2 meters

U23

N/A

G5-0

included

U22

G2-5

G5-1

1 meter

U21

G3-0

G0-6

2 meters

U20

G2-4

G5-2

2 meters

U18

G2-2

G5-4

2 meters

U16

G1-6

G4-0

2 meters

U14

G2-0

G5-6

2 meters

U12

G1-4

G4-2

2 meters

U10

G1-2

G4-4

2 meters

U8

G1-0

G4-6

2 meters

U6

G0-6

G3-0

2 meters

U4

G0-4

G3-2

2 meters

U2

G0-2

G3-4

2 meters

U1

G0-0

G3-6

2 meters

The following table shows the cable connections from the PDUs to the rack units in Oracle Exadata Storage Expansion Quarter Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers.

Table 23-38 Three Phase PDU Cabling for Oracle Exadata Storage Expansion Quarter Rack with Exadata Storage Server with Sun Fire X4270 M2 Servers

Rack Unit PDU-A/PS-00 PDU-B/PS-01 Cable Length

U24

G3-1

G0-5

2 meters

U23

N/A

G5-0

included

U22

G2-5

G5-1

1 meter

U21

G3-0

G0-6

2 meters

U20

G2-4

G5-2

2 meters

U8

G1-0

G4-6

2 meters

U6

G0-6

G3-0

2 meters

U4

G0-4

G3-2

2 meters

U2

G0-2

G3-4

2 meters